Service Processor MAPs
How to run the 3746-900 Service Processor Link Restart
1. Set the 'service mode' to 'maintenance':
a. Press the 'Service mode' key until the
number '1' is displayed in the service
window.
b. Press the 'validate' key.
2. Start the test as follows:
a. Press the 'Function' key until the number
'6' is displayed in the function window.
b. Press the 'validate' key.
3. Observe the display and note the value of the
SRC displayed:
.
a. 05B0B0FD: Request sent
b. 05B0B0FE: Request rejected (TIC3
resource already actives, operator error)
c. 05B0B0FF: Request not received (time
out, CBSP failure).
4. On the display, note the value of the 'Service
processor not accessible' window.
The value can be:
¹
' ': Console accessible, the link is estab-
lished
¹
'*': Physical link not active
¹
'$': Disconnected at SSA level
¹
'A': 'OK' frame received on 'Hello' frame
¹
'B': Permanent beaconing
¹
'C': Connected at DLC level
¹
'D': Disconnected
¹
'E': Internal error
¹
'F': 'Hello' frame sent
¹
'G': Ring failure
¹
'H': Hardware error
¹
'I': Inserted
¹
'L': Lobe wire fault or Lobe media fault
¹
'N': Inserting on LANor retrying insertion
¹
'R': Link reset
¹
'T': Time out retries exhausted
¹
'U': TIC3 unplugged.
¹
'5': Congestion of CBSP during general
IML (transient problem)
5. If the 'Service processor not accessible'
window is not blank, note the control panel
code displayed on the 3746-900 front panel (if
one appears). Then go to “3746-900 Control
Panel Codes” on page 1-15 and follow the
procedure, or go to “MAP 2750: 3746-900
Permanent Service Processor Link Problem”
on page 2-94
6. Press the 'exit' key to quit this function.
3-16
3746-900: Service Guide
Summary of Contents for FlashSystem 900
Page 1: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Page 2: ......
Page 3: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Page 14: ...xii 3746 900 Service Guide...
Page 16: ...xiv 3746 900 Service Guide...
Page 22: ...xx 3746 900 Service Guide...
Page 29: ...Safety Figure 0 3 Ground Wire Connection On Controller Expansion SAFETY xxvii...
Page 60: ...Safety lviii 3746 900 Service Guide...
Page 61: ...Safety SAFETY lix...
Page 62: ...Safety lx 3746 900 Service Guide...
Page 63: ...Safety SAFETY lxi...
Page 64: ...Safety lxii 3746 900 Service Guide...
Page 65: ...Safety SAFETY lxiii...
Page 66: ...Safety lxiv 3746 900 Service Guide...
Page 67: ...Safety...
Page 68: ...Safety lxvi 3746 900 Service Guide...
Page 69: ...Safety SAFETY lxvii...
Page 70: ...Safety lxviii 3746 900 Service Guide...
Page 71: ...Safety...
Page 72: ...Safety lxx 3746 900 Service Guide...
Page 73: ...Safety SAFETY lxxi...
Page 74: ...Safety lxxii 3746 900 Service Guide...
Page 75: ...Safety SAFETY lxxiii...
Page 76: ...Safety lxxiv 3746 900 Service Guide...
Page 77: ...Safety SAFETY lxxv...
Page 78: ...Safety lxxvi 3746 900 Service Guide...
Page 92: ...Safety xc 3746 900 Service Guide...
Page 94: ...Safety xcii 3746 900 Service Guide...
Page 129: ...3746 900 FRU Exchange 010 continued Go to MAP Ready LED ON on page 1 52 Chapter 1 START 1 35...
Page 276: ...3746 900 MAPs Figure 2 6 CP2 Circuit 2 18 3746 900 Service Guide...
Page 325: ...3746 900 MAPs 026 continued Go to Step 014 on page 2 65 Chapter 2 MAPs for FRU Isolation 2 67...
Page 340: ...3746 900 MAPs 113 continued Go to Step 001 on page 2 68 2 82 3746 900 Service Guide...
Page 414: ...Service Processor MAPs 2 156 3746 900 Service Guide...
Page 484: ...FRU Exchange Figure 4 16 3746 Model 9x0 CBSP Cassette 4 18 3746 900 Service Guide...
Page 495: ...FRU Exchange Figure 4 23 3746 900 Rear of DC Power Box Chapter 4 3746 900 FRU Exchange 4 29...
Page 510: ...FRU Exchange Figure 4 39 3746 900 LIC16 Coupler 4 44 3746 900 Service Guide...
Page 520: ...FRU Exchange Figure 4 45 3746 900 Transformer Handling 4 54 3746 900 Service Guide...
Page 522: ...FRU Exchange 4 56 3746 900 Service Guide...
Page 542: ......
Page 545: ......