Service Processor MAPs
How to Run the 3746-900 Control Panel Test
This test can be run without stopping the custom-
er's application.
It is not a sequential test and can be cancelled at
any time by pressing the 'Exit' key.
Notes:
1. Any inactivity lasting about 60 seconds during
the control panel test results in the test being
automatically cancelled. The panel returns to
operational mode.
2. During this test the control panel's audible
alarm sounds for each action.
'special character': Can be described as when
every possible segment of the window is lit.
- -
|\|/|
- -
|/|\|
- -
1. Set power to local:
a. Press the 'Power Control' key until '3' is
displayed in the power control window.
b. Press the 'Validate' key.
If the above action cannot be performed,
go to step 11.
2. Set service mode to maintenance.
a. Press the 'Service mode' key until the
number '1' is displayed in the service
window.
b. Press the 'Validate' key.
If the above action cannot be performed
go to step 11.
3. Set 'Function' to panel test:
a. Press the 'Function' key until '5' is dis-
played in the function window.
b. Press the 'Validate' key.
If the above action cannot be performed
go to step 11.
On the display, All 10 'special character' is dis-
played.
If the pattern is not identical for each of the 10
special characters, go to step 11.
Note: If the panel test code detects an error
the SRC is stacked but not displayed on the
panel. Therefore, if the link with the service
processor is operational, the SRC will be sent
to the MOSS-E.
4. Press the 'Function' key.
On the display, the 'Function' window 'special
character' will be displayed. Repetitive action
will scroll through the 'Function' and 'Code'
windows sequentially and wrap around.
If this does not occur, go to step 11.
5. Press the 'Service mode' key.
On the display, the 'Service mode' window
'special character' is displayed. Repetitive
action will scroll through the 'Service mode'
and 'Power Control' windows and wrap
around.
If this does not occur, go to step 11.
6. Press the 'Power Control' key.
On the display, the 'Service processor not
accessible' window 'special character' is dis-
played. Repetitive action will scroll through
the 'All channels disabled' 'Service processor
not accessible' windows sequentially and wrap
around.
If this does not occur, go to step 11.
7. Press the 'Start' key.
On the display, '8' is displayed in the 'Func-
tion' window, and the ready or standby LEDs
will light if not already ON. (ready and
standby LEDs can not be ON at the same
time).
If this does not occur, go to step 11.
8. Press the 'Standby' key.
The display is completely blank.
If this does not occur, go to step 11.
9. Press the 'Exit' key.
On the display, the 'Power Control' (3) and
'Service Mode' (1) are displayed indicating that
the test is complete, and that the control panel
has returned to operational mode.
If this does not occur, go to step 11.
10. The control panel test is complete. No
error has been detected. Ignore step 11
11. Go to “MAP 2620: 3746-900 Control Panel
Problem” on page 2-43.
Chapter 3. How to Run Diagnostics
3-15
Summary of Contents for FlashSystem 900
Page 1: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Page 2: ......
Page 3: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Page 14: ...xii 3746 900 Service Guide...
Page 16: ...xiv 3746 900 Service Guide...
Page 22: ...xx 3746 900 Service Guide...
Page 29: ...Safety Figure 0 3 Ground Wire Connection On Controller Expansion SAFETY xxvii...
Page 60: ...Safety lviii 3746 900 Service Guide...
Page 61: ...Safety SAFETY lix...
Page 62: ...Safety lx 3746 900 Service Guide...
Page 63: ...Safety SAFETY lxi...
Page 64: ...Safety lxii 3746 900 Service Guide...
Page 65: ...Safety SAFETY lxiii...
Page 66: ...Safety lxiv 3746 900 Service Guide...
Page 67: ...Safety...
Page 68: ...Safety lxvi 3746 900 Service Guide...
Page 69: ...Safety SAFETY lxvii...
Page 70: ...Safety lxviii 3746 900 Service Guide...
Page 71: ...Safety...
Page 72: ...Safety lxx 3746 900 Service Guide...
Page 73: ...Safety SAFETY lxxi...
Page 74: ...Safety lxxii 3746 900 Service Guide...
Page 75: ...Safety SAFETY lxxiii...
Page 76: ...Safety lxxiv 3746 900 Service Guide...
Page 77: ...Safety SAFETY lxxv...
Page 78: ...Safety lxxvi 3746 900 Service Guide...
Page 92: ...Safety xc 3746 900 Service Guide...
Page 94: ...Safety xcii 3746 900 Service Guide...
Page 129: ...3746 900 FRU Exchange 010 continued Go to MAP Ready LED ON on page 1 52 Chapter 1 START 1 35...
Page 276: ...3746 900 MAPs Figure 2 6 CP2 Circuit 2 18 3746 900 Service Guide...
Page 325: ...3746 900 MAPs 026 continued Go to Step 014 on page 2 65 Chapter 2 MAPs for FRU Isolation 2 67...
Page 340: ...3746 900 MAPs 113 continued Go to Step 001 on page 2 68 2 82 3746 900 Service Guide...
Page 414: ...Service Processor MAPs 2 156 3746 900 Service Guide...
Page 484: ...FRU Exchange Figure 4 16 3746 Model 9x0 CBSP Cassette 4 18 3746 900 Service Guide...
Page 495: ...FRU Exchange Figure 4 23 3746 900 Rear of DC Power Box Chapter 4 3746 900 FRU Exchange 4 29...
Page 510: ...FRU Exchange Figure 4 39 3746 900 LIC16 Coupler 4 44 3746 900 Service Guide...
Page 520: ...FRU Exchange Figure 4 45 3746 900 Transformer Handling 4 54 3746 900 Service Guide...
Page 522: ...FRU Exchange 4 56 3746 900 Service Guide...
Page 542: ......
Page 545: ......