3746-900 FRU Exchange
MAP: Ready LED Blinking
You are here because the 3746-900 has its ready LED blinking with an error control panel code perma-
nently displayed or flashing.
001
¹
Set the 3746-900 to Offline mode if not already done.
– Return to the "3746-9x0 Menu" window.
– Click on the "Problem management" option.
– Double click on the "Set 3746-9x0 Online/Offline Option".
– On the "Set 3746-9x0 Online/Offline" window, click on "YES" or "NO" according to the current
setting.
– On the next "Set 3746-9x0 Online/Offline" window, click on "OK".
– Select the FRU on your FRU list with the highest fault probability, then go to Step 002.
002
Is this FRU the CBSP or the TIC3 of the CBSP?
Yes No
003
Go to Step 005.
004
¹
If you change the CBSP go, to Step 026 on page 1-51.
¹
If you change the TIC3 of the CBSP, go to Step 018 on page 1-50
005
¹
Switch the CB1(s) OFF on your 3746-900.
¹
Go to Chapter 4, “3746-900 FRU Exchange” on page 4-1 to exchange the FRU on your FRU list with
the highest fault probability, then return here.
¹
If not already done, switch the CB1(s) ON.
¹
After a power ON the standby LED blinks for about 20 seconds. Then it should remain ON, or else
the ready LED blinks until the end of IML (about 3 minutes) and then comes permanently ON.
Is the Standby LED ON?
Yes No
006
Is the ready LED blinking?
Yes No
007
Go to Step 010
008
¹
Wait for about 3 minutes at the end of IML.
¹
Go to Step 013 on page 1-50.
009
¹
Press the 'Start' key on the 3746-900 control panel.
¹
Wait for about 3 minutes at the end of IML.
¹
Go to Step 013 on page 1-50.
010
(Step 010 continues)
Chapter 1. START
1-49
Summary of Contents for FlashSystem 900
Page 1: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Page 2: ......
Page 3: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Page 14: ...xii 3746 900 Service Guide...
Page 16: ...xiv 3746 900 Service Guide...
Page 22: ...xx 3746 900 Service Guide...
Page 29: ...Safety Figure 0 3 Ground Wire Connection On Controller Expansion SAFETY xxvii...
Page 60: ...Safety lviii 3746 900 Service Guide...
Page 61: ...Safety SAFETY lix...
Page 62: ...Safety lx 3746 900 Service Guide...
Page 63: ...Safety SAFETY lxi...
Page 64: ...Safety lxii 3746 900 Service Guide...
Page 65: ...Safety SAFETY lxiii...
Page 66: ...Safety lxiv 3746 900 Service Guide...
Page 67: ...Safety...
Page 68: ...Safety lxvi 3746 900 Service Guide...
Page 69: ...Safety SAFETY lxvii...
Page 70: ...Safety lxviii 3746 900 Service Guide...
Page 71: ...Safety...
Page 72: ...Safety lxx 3746 900 Service Guide...
Page 73: ...Safety SAFETY lxxi...
Page 74: ...Safety lxxii 3746 900 Service Guide...
Page 75: ...Safety SAFETY lxxiii...
Page 76: ...Safety lxxiv 3746 900 Service Guide...
Page 77: ...Safety SAFETY lxxv...
Page 78: ...Safety lxxvi 3746 900 Service Guide...
Page 92: ...Safety xc 3746 900 Service Guide...
Page 94: ...Safety xcii 3746 900 Service Guide...
Page 129: ...3746 900 FRU Exchange 010 continued Go to MAP Ready LED ON on page 1 52 Chapter 1 START 1 35...
Page 276: ...3746 900 MAPs Figure 2 6 CP2 Circuit 2 18 3746 900 Service Guide...
Page 325: ...3746 900 MAPs 026 continued Go to Step 014 on page 2 65 Chapter 2 MAPs for FRU Isolation 2 67...
Page 340: ...3746 900 MAPs 113 continued Go to Step 001 on page 2 68 2 82 3746 900 Service Guide...
Page 414: ...Service Processor MAPs 2 156 3746 900 Service Guide...
Page 484: ...FRU Exchange Figure 4 16 3746 Model 9x0 CBSP Cassette 4 18 3746 900 Service Guide...
Page 495: ...FRU Exchange Figure 4 23 3746 900 Rear of DC Power Box Chapter 4 3746 900 FRU Exchange 4 29...
Page 510: ...FRU Exchange Figure 4 39 3746 900 LIC16 Coupler 4 44 3746 900 Service Guide...
Page 520: ...FRU Exchange Figure 4 45 3746 900 Transformer Handling 4 54 3746 900 Service Guide...
Page 522: ...FRU Exchange 4 56 3746 900 Service Guide...
Page 542: ......
Page 545: ......