FRU Exchange
¹
Return to the step in the MAP you
were performing.
3. The Standby LED or the Ready LED is
blinking
a. From the service processor, return to the
"MOSS-E VIEW" window and double click
on the service processor icon.
b. On the "Service Processor Menu" window,
click on the "Configuration Management"
option.
Then double click on the
"Manage 3745/3746-900
Installation/Removal" option.
c. On the "Controller Installation" window,
select the machine by clicking on the
serial number of the machine for which
you are called and click on "repair".
d. On the "Repair Actions for 3746-900"
window, select the "Change 3746-900
CBSA TIC3" option and click on "OK".
e. The "Controller Repair Message" window
is displayed. Perform the following steps
before clicking on "OK".
f. Locate the TIC3 cassette using
Figure 4-10 on page 4-9.
g. WARNING: Use the ESD kit and proce-
dures.
h. Using the labels on the doors for refer-
ence, loosen the screws which secure the
cable.
i. Remove the cable.
j. Press the two unlocking buttons and pull
the cassette out.
k. Exchange the TIC3 cassette.
l. Insert the new TIC3 into the enclosure
and slide it firmly until it clicks (locks in).
m. Replace the removed cable, then tighten
the screws.
n. Do a service processor link restart from
the 3746-900 control panel.
¹
Select function 6.
¹
Press the 'Validate' key.
¹
If you are not able to perform the pre-
ceding two steps, the problem is not in
the TIC3. Remove the TIC3 that you
have installed and reinstall the pre-
vious TIC3 (using the previous steps h
to m). Then return to the step in the
MAP you were performing.
¹
If you are able to start the service
processor link restart, a general IML is
started. A normal IML must be termi-
nated by 00000000 displayed on the
control panel and the ready LED ON
after about 3 minutes. If the standby
LED is ON, press the 'start' key to end
the IML. In case a problem occurs
during IML, a code is displayed on the
control panel. This code can be
flashing or steady (more than 60
seconds) while the ready LED is
blinking. According to the control
panel code displayed perform the
specified action:
Panel code Action
00000000
Return to the "Controller
Repair Message" window
and click on "OK". Then
go to the next bullet.
Other code Suspect a problem in
other part of the
machine. Remove the
TIC3 that you have
installed and reinstall the
previous TIC3 (using the
previous steps h to i).
Return to the "Controller
Repair Message" window
and click on "Cancel".
Then return to the step
in the MAP you were
performing.
¹
On the "Controller Installation"
window, click on "Save".
¹
A new window prompts you to install
the installation diskette in the service
processor. When it is done click on
"OK".
¹
A "Controller Saving Message" is dis-
played. Remove the diskette and click
on "OK".
¹
The "Controller Installation" window is
again displayed, click on "Cancel".
¹
Return to the step in the MAP you
were performing.
4-50
3746-900: Service Guide
Summary of Contents for FlashSystem 900
Page 1: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Page 2: ......
Page 3: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Page 14: ...xii 3746 900 Service Guide...
Page 16: ...xiv 3746 900 Service Guide...
Page 22: ...xx 3746 900 Service Guide...
Page 29: ...Safety Figure 0 3 Ground Wire Connection On Controller Expansion SAFETY xxvii...
Page 60: ...Safety lviii 3746 900 Service Guide...
Page 61: ...Safety SAFETY lix...
Page 62: ...Safety lx 3746 900 Service Guide...
Page 63: ...Safety SAFETY lxi...
Page 64: ...Safety lxii 3746 900 Service Guide...
Page 65: ...Safety SAFETY lxiii...
Page 66: ...Safety lxiv 3746 900 Service Guide...
Page 67: ...Safety...
Page 68: ...Safety lxvi 3746 900 Service Guide...
Page 69: ...Safety SAFETY lxvii...
Page 70: ...Safety lxviii 3746 900 Service Guide...
Page 71: ...Safety...
Page 72: ...Safety lxx 3746 900 Service Guide...
Page 73: ...Safety SAFETY lxxi...
Page 74: ...Safety lxxii 3746 900 Service Guide...
Page 75: ...Safety SAFETY lxxiii...
Page 76: ...Safety lxxiv 3746 900 Service Guide...
Page 77: ...Safety SAFETY lxxv...
Page 78: ...Safety lxxvi 3746 900 Service Guide...
Page 92: ...Safety xc 3746 900 Service Guide...
Page 94: ...Safety xcii 3746 900 Service Guide...
Page 129: ...3746 900 FRU Exchange 010 continued Go to MAP Ready LED ON on page 1 52 Chapter 1 START 1 35...
Page 276: ...3746 900 MAPs Figure 2 6 CP2 Circuit 2 18 3746 900 Service Guide...
Page 325: ...3746 900 MAPs 026 continued Go to Step 014 on page 2 65 Chapter 2 MAPs for FRU Isolation 2 67...
Page 340: ...3746 900 MAPs 113 continued Go to Step 001 on page 2 68 2 82 3746 900 Service Guide...
Page 414: ...Service Processor MAPs 2 156 3746 900 Service Guide...
Page 484: ...FRU Exchange Figure 4 16 3746 Model 9x0 CBSP Cassette 4 18 3746 900 Service Guide...
Page 495: ...FRU Exchange Figure 4 23 3746 900 Rear of DC Power Box Chapter 4 3746 900 FRU Exchange 4 29...
Page 510: ...FRU Exchange Figure 4 39 3746 900 LIC16 Coupler 4 44 3746 900 Service Guide...
Page 520: ...FRU Exchange Figure 4 45 3746 900 Transformer Handling 4 54 3746 900 Service Guide...
Page 522: ...FRU Exchange 4 56 3746 900 Service Guide...