Control Panel LED Status Versus 3746-900 States
IML Request Versus 3746 Model 900 States
The CBSA IML, the general IML, the service processor link restart function started from the control panel,
and the selective IML on a processor started from the MOSS-E are all executed (or not) depending on the
initial 3746-900 state.
The requested action is started only if the 3746-900 is in ready state. If not, a default action is started as
shown in the following table.
Notes:
1. The final state is standby.
2. The final state is ready.
Table
1-6. LED Status Versus 3746-900 States
Standby
LED
Ready LED
3746-900
State
Comment
Blinking
OFF
AC ON
Initialization of the CBSP hardware, and the 3746-900 waits for
first recognition by the MOSS-E on LAN connection.
ON
OFF
Standby
The 3746-900, initially recognized by the MOSS-E, waits for a
power ON condition, (only the CBSP EEPROM code is
running).
OFF
Blinking
Power ON
IML loading in all 3746-900 processors.
OFF
ON
Ready
The 3746-900 is now available.
Table
1-7. IML Request Versus 3746-900 States
Initial
3746-900 State
CBSA IML
Request (1/4)
General IML
Request (0/3)
Selective IML
Request
Service
Processor
Link Restart (6)
AC ON (Note 1)
General IML (0/3)
General IML (0/3)
NA
General IML (3)
Standby (Note 1)
General IML (0/3)
General IML (0/3)
NA
General IML (3)
Power ON
/IML in progress
(Note 2)
General IML (0/3)
General IML (0/3)
NA
General IML (3)
Ready (Note 2)
CBSA IML (1/4)
General IML (0/3)
Selective IML
Service Processor
Link Restart (6)
CBSA IML
in progress
(Note 2)
CBSA IML (1/4)
General IML (0/3)
NA
CBSA IML (1/4)
Selective IML
(Note 2)
CBSA IML (1/4)
General IML (0/3)
Wait previous
selective IML end
Service Processor
Link Restart (6)
1-164
3746-900: Service Guide
Summary of Contents for FlashSystem 900
Page 1: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Page 2: ......
Page 3: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Page 14: ...xii 3746 900 Service Guide...
Page 16: ...xiv 3746 900 Service Guide...
Page 22: ...xx 3746 900 Service Guide...
Page 29: ...Safety Figure 0 3 Ground Wire Connection On Controller Expansion SAFETY xxvii...
Page 60: ...Safety lviii 3746 900 Service Guide...
Page 61: ...Safety SAFETY lix...
Page 62: ...Safety lx 3746 900 Service Guide...
Page 63: ...Safety SAFETY lxi...
Page 64: ...Safety lxii 3746 900 Service Guide...
Page 65: ...Safety SAFETY lxiii...
Page 66: ...Safety lxiv 3746 900 Service Guide...
Page 67: ...Safety...
Page 68: ...Safety lxvi 3746 900 Service Guide...
Page 69: ...Safety SAFETY lxvii...
Page 70: ...Safety lxviii 3746 900 Service Guide...
Page 71: ...Safety...
Page 72: ...Safety lxx 3746 900 Service Guide...
Page 73: ...Safety SAFETY lxxi...
Page 74: ...Safety lxxii 3746 900 Service Guide...
Page 75: ...Safety SAFETY lxxiii...
Page 76: ...Safety lxxiv 3746 900 Service Guide...
Page 77: ...Safety SAFETY lxxv...
Page 78: ...Safety lxxvi 3746 900 Service Guide...
Page 92: ...Safety xc 3746 900 Service Guide...
Page 94: ...Safety xcii 3746 900 Service Guide...
Page 129: ...3746 900 FRU Exchange 010 continued Go to MAP Ready LED ON on page 1 52 Chapter 1 START 1 35...
Page 276: ...3746 900 MAPs Figure 2 6 CP2 Circuit 2 18 3746 900 Service Guide...
Page 325: ...3746 900 MAPs 026 continued Go to Step 014 on page 2 65 Chapter 2 MAPs for FRU Isolation 2 67...
Page 340: ...3746 900 MAPs 113 continued Go to Step 001 on page 2 68 2 82 3746 900 Service Guide...
Page 414: ...Service Processor MAPs 2 156 3746 900 Service Guide...
Page 484: ...FRU Exchange Figure 4 16 3746 Model 9x0 CBSP Cassette 4 18 3746 900 Service Guide...
Page 495: ...FRU Exchange Figure 4 23 3746 900 Rear of DC Power Box Chapter 4 3746 900 FRU Exchange 4 29...
Page 510: ...FRU Exchange Figure 4 39 3746 900 LIC16 Coupler 4 44 3746 900 Service Guide...
Page 520: ...FRU Exchange Figure 4 45 3746 900 Transformer Handling 4 54 3746 900 Service Guide...
Page 522: ...FRU Exchange 4 56 3746 900 Service Guide...
Page 542: ......
Page 545: ......