1309
Drive
drive_ID
failure detected - Drive failed to reassign sector, current drive status is
[
inuse
|
spare
]
Explanation:
Drive failure process initiated because the drive returned an error on a reassign sector command.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
notified of this alert by e-mail. Alert 1300 or 1301 is also generated. Alert clears when the drive is removed.
Operator response:
Replace the failed drive (see “Replacing a failed drive” on page 167).
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
1310
Drive
drive_ID
status has been changed from unassigned to unreliable
Explanation:
Due to metadata read from a newly discovered drive, a previously unassigned drive has been marked
unreliable. Possible causes:
v
Drive reports reassign block failure.
v
Drive exceeded configured maximum media error threshold per drive.
System action:
Drive mount state is set to DISMOUNTED. By default, the SAS RAID Module system information
indicator is not turned on and the operator is notified of this alert by e-mail. Alert clears immediately if the drive is
removed. Alert clears automatically after 120 seconds.
Operator response:
Acknowledge to clear the alert immediately. Replace the drive (see “Replacing a failed drive” on
2300
Drive
drive_ID
ready for service
Explanation:
Drive is ready for removal. Possible causes:
v
Dismount request from operator
v
Presence of an unreliable drive (failed or undiscoverable yet detected by SES)
v
Presence of an unsupported drive
System action:
Drive fault light turns on, indicating "ready to remove" state. By default, the SAS RAID Module
system information indicator is turned on and the operator is notified of this alert by e-mail. Alert clears when the
drive is removed or the drive mount state changes (to unmounted or mounted).
Operator response:
Remove the drive.
4300
Unsupported drive
drive_ID
detected
Explanation:
Drive lockout active due to unsupported drive.
System action:
Controller rejects all configuration commands until the unsupported drive is removed. By default,
the SAS RAID Module system information indicator is turned on and the operator is notified of this alert by e-mail.
Alert clears when the unsupported drive is removed.
Operator response:
Remove the unsupported drive.
1309 • 4300
134
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
Summary of Contents for BladeCenter S SAS RAID Controller Module
Page 2: ......
Page 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Page 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Page 209: ...Taiwan Class A compliance statement Notices 199...
Page 215: ......
Page 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...