Updating controller firmware
To manually update the firmware of a SAS RAID Module, perform the following
steps.
Procedure
1.
Download the SAS Switch firmware.
a.
Log into IBM Storage Configuration Manager.
b.
Select
BCS SAS RAID Module
>
Service
>
Update Firmware
.
c.
Next to
Current Device
, select the bay of the affected SAS RAID Module.
d.
Under
Download Firmware Bundle
, click
Check web for latest available
updates
.
e.
Under
Popular links
, click
Software and device drives
.
f.
Under
IBM BladeCenter
click
BladeCenter S
g.
Click on
Serial attached SCSI (SAS)
.
h.
Next to
SAS Connectivity Module firmware – IBM BladeCenter
, click the
version number.
i.
Under
File link
, click the .zip link next to
SAS Connectivity Module
firmware
.
j.
Under
Transfer protocol
, select
FTP
.
k.
Click
I agree
to accept the terms and conditions.
l.
Save the ZIP file on your local workstation.
m.
Unzip the file.
2.
Put the SAS RAID Modules into service mode.
a.
At the top of the Update Firmware page, click
Shutdown & Recover
.
b.
Select
Shut down to service mode
.
c.
Select
Both Controller 1 and 2
.
d.
Click
OK
.
e.
Read the Confirmation Message and click
OK
.
f.
Verify that the following message is displayed at the top of the Shutdown
and Recover page:
The controllers were successfully shut down to
service mode. Continue to the Update Firmware page to proceed with
your firmware update.
This message indicates that the SAS RAID Modules
are in service mode.
g.
At the top of the Shutdown and Recover page, click
Update Firmware
.
3.
Update the SAS Switch firmware on the affected SAS RAID Module.
a.
Next to
Current Device
, select the location of the affected SAS RAID
Module.
b.
Click
Browse
.
c.
Select the FUF file from the ZIP file.
d.
Click
Open
.
e.
Click
Install
.
f.
Read the Confirmation Message and click
OK
.
4.
Verify that the following message is displayed at the top of the Update
Firmware page:
Firmware update has completed successfully. If both SAS
Switches are now up to date, RAID controllers need to be rebooted to
come back online. Go to Shutdown and Recover page to reboot both
controllers.
This message indicates that the SAS Switch firmware update
completed successfully.
160
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
Summary of Contents for BladeCenter S SAS RAID Controller Module
Page 2: ......
Page 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Page 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Page 209: ...Taiwan Class A compliance statement Notices 199...
Page 215: ......
Page 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...