validate key
The
validate key
command sets or displays the license key in the system.
Command arguments:
<CLI> validate key [-get | -set <192_bit_key>]
Where:
v
-get
- Displays the current license key.
v
-set
- Sets a new 192–bit license key.
Example setting the key:
<cli> validate key -set 3a288d5ec2cef28c61510c11f6c64a69afae7e678f6c216f
Current Machine Local Time: 08/26/2008
03:24:43 PM
License Key
3a288d5ec2cef28c61510c11f6c64a69afae7e678f6c216f has been set successfully
Example getting the current key:
<cli> validate key –get
Current Machine Local Time: 08/26/2008
03:24:43 PM
License Key
: 3a288d5ec2cef28c61510c11f6c64a69afae7e678f6c216f
Volume management commands
Use the RAID Controller command line interface for the RAID controller to
perform administrative tasks for the device. This topic details the commands you
can use to manage your storage volumes.
add mirror
Use this command to add a mirror to an existing drive pool. Mirrors can only be
added to a RAID 0 pool. Drives must be added in pairs and must not have a
smaller capacity than the existing drives in the RAID 0 pool.
Important:
This command requires you to end all application I/O processes and
shut down any active Blade servers in accordance with the recommended
non-concurrent practices. The
add mirror
command must complete before you
resume any application I/O processes. Depending on the size of the drives,
add
mirror
may take several hours to complete. If one of the Blade servers being shut
down is used as the RAID controller management node and has logical unit
numbers (LUNs) mapped to it, you must use an external Blade server to manage
the RAID subsystem.
Command arguments:
<CLI>
add mirror -pool [POOL_NAME] -drives [ENCLOSURE]:[TRAY][ENCLOSURE]:[TRAY]..
Where:
v
[POOL_NAME]
- Specifies the name of the drive pool.
v
[ENCLOSURE]:[TRAY]
- Specifies the drive bay number by enclosure number and
tray number.
Example:
<CLI> add mirror -pool Grp1 -drives 1:1 1:3
78
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
Summary of Contents for BladeCenter S SAS RAID Controller Module
Page 2: ......
Page 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Page 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Page 209: ...Taiwan Class A compliance statement Notices 199...
Page 215: ......