0215
Battery
battery_ID
firmware update complete
Explanation:
When the system boots up or a battery is inserted, the controller checks the battery firmware level. If
the firmware does not match the expected version, the controller automatically performs a firmware update and then
generates this alert to indicate that a firmware mismatch was detected and corrected.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response:
Acknowledge to clear the alert immediately.
1200
Battery
battery_ID
nearing expiration date (
date
)
Explanation:
The battery has expiration date tracking, and the expiration date is between 14 and 90 days from now.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when battery is removed or battery status changes to “expiration
imminent” (alert 1201).
Operator response:
Replace the battery (see “Replacing a Battery Backup Unit” on page 177).
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
1201
Battery
battery_ID
expiration date (
date
) imminent
Explanation:
The battery has expiration date tracking, and the expiration date is less than 15 days from now.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when the battery is removed or battery status changes to “expired” (alert
1202).
Operator response:
Replace the battery (see “Replacing a Battery Backup Unit” on page 177).
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
1202
Battery
battery_ID
expired (
date
)
Explanation:
The battery has expiration date tracking, and the battery expiration date has passed.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when the battery is removed.
Operator response:
Replace the battery (see “Replacing a Battery Backup Unit” on page 177).
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
1203
Battery
battery_ID
failed (code
failure_code
)
Explanation:
No working battery is detected. Possible causes include:
v
Battery communication error or timeout
v
Missing battery
v
Charging system failure
v
Battery has passed its expiration date
v
Battery temperature out of Spec range
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when the battery is removed.
Operator response:
Correct the problem. Ensure that a working battery is in place (see “Replacing a Battery Backup
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
0215 • 1203
126
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
Summary of Contents for BladeCenter S SAS RAID Controller Module
Page 2: ......
Page 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Page 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Page 209: ...Taiwan Class A compliance statement Notices 199...
Page 215: ......
Page 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...