5500
Host-LUN mapping conflict while mounting drive group. Host:LUN
LUN
maps to Group:Volume
group_ID
:
volume_ID
.
Explanation:
LUN mapping conflict resolved during mount.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response:
Acknowledge to clear the alert immediately.
5501
AutoHost overlap during mount of group
group_ID
. Volume
volume_ID
included for AutoHost
host_ID
.
Explanation:
Auto host overlap detected during mount.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response:
Acknowledge to clear the alert immediately.
9503
Host-LUN mapping conflict during mount of group
group_ID
. Host
host_ID
has no available LUNs
for mapping volume
volume_ID
. Host LUN
LUN
mapping deleted.
Explanation:
Unresolvable LUN conflict.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response:
Acknowledge to clear the alert immediately. Reconfigure LUN mapping.
9504
Volume
volume_ID
dismounted with data in write cache
Explanation:
A transition to non-viable state occurred or volume was disorderly dismounted and the volume had at
least one sector of unflushed dirty cache.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail.
Operator response:
Acknowledge to clear the alert immediately.
9510
Drive group
group_ID
maximum bad blocks exceeded - Volume
volume_ID
deleted
Explanation:
The Bad Block count for the drive group has exceeded the maximum value.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail. The volume is deleted.
Operator response:
Acknowledge to clear the alert immediately.
5500 • 9510
146
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
Summary of Contents for BladeCenter S SAS RAID Controller Module