Table 7. Service mode conditions
Reason
Description
Controller action
SES_FAILURE
Controller is unable to
communicate with SES
device
Service Mode - Reboot or
Replace
BMC_FAILURE
Controller is unable to
communicate with BMC
device
Service Mode - Reboot or
Replace
VPD_NOACCESS
Controller is unable to
access VPD data
Service Mode - Reboot or
Replace
HW_FAILURE
Unrecoverable hardware
error
Service Mode - Reboot or
Replace
HW_RECURRING_FAILURE
Recoverable hardware
error has caused multiple
reboots
Service Mode - Reboot or
Replace
SW_RECURRING_FAILURE
Firmware detected error
has caused multiple
reboots
Service Mode - Reboot or
Replace
FORCED_NON_SURVIVOR
Failover condition
occurred and other
controller was better
qualified to become
survivor.
Service Mode - Reboot or
Replace Error log shows
controller, drive, and SES
data on which basis a
survivor was chosen.
(Includes mirror path
down, tie breaker cases,
host port down, etc.)
DRV_MSMTCH_RB
Rebinder does not see the
same drives as survivor.
Service Mode - Reboot or
Replace
DRV_MSMTCH_ST
On boot up (warm or
cold) both controllers
discover a different set of
drives and neither
controller's discovered
drives is a superset of the
other's.
Service Mode - Reboot or
Replace (Note that both
controllers will be in
service mode.)
SES_ERRS
The controller detected
environmental conditions
unsuitable for normal
operation.
Service Mode - Reboot
after environmentals
return to normal
INDETERMINATE_DATA_LOSS
Controller is unable to
proceed with out loosing
data - PROCEED AT
OWN RISK
Service Mode - Reboot,
Replace, or Force boot
with data loss
BATTERY_LOW,
BATTERY_FAILED
If "Writeback mode
without battery" is false,
enter service mode, else
report error in log and
continue normally
Service Mode - Reboot
when battery OK
Command arguments:
<CLI> service mode –getreason
Reason details : string
Recovery Hints : string
74
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
Summary of Contents for BladeCenter S SAS RAID Controller Module
Page 2: ......
Page 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Page 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Page 209: ...Taiwan Class A compliance statement Notices 199...
Page 215: ......