<CLI> list enclosure
Current Machine Local Time: 09/15/2009 02:22:06 PM
_________________________________________________________
| Encl# | Enclosure
| Type
| Version | Status |
|_______|________________|____________|_________|________|
| 0
| Encl0
| Controller | 0107
| Good
|
| 1
| Encl1
| DSM
| 1.06
| Good
|
| 2
| Encl2
| DSM
| 1.08
| Good
|
|_______|________________|____________|_________|________|
19.
Enter
mountstate –getobject –enclosure
and press Enter to list the mount
state of the DSMs. Ensure that each DSM is online.
<CLI> mountstate -getobject -enclosure
Current Machine Local Time: 09/15/2009 02:23:46 PM
_______________________________________________________
| Enclosure# | State
| Type
|
|____________|_______________________|_________________|
| 0
| Online
| Controller
|
| 1
| Online
| DSM
|
| 2
| Online
| DSM
|
|____________|_______________________|_________________|
20.
Enter
list drive
and press Enter to list the drive summary for each disk
drive configured in the storage pool. Ensure that the mount state of all disk
drives inside the replacement DSM are in the online state.
<CLI> list drive
Current Machine Local Time: 09/15/2009 02:25:04 PM
__________________________________________________________________________________________
|Drive#| E:T| SerialNo | Cap | Pool
|Usage|State|Mount State|Ctl0|Ctl1| RPM |FW level|
|______|____|__________|_____|___________|_____|_____|___________|____|____|_____|________|
| 0
| 1:1| 9QK0SWLM |698GB|RAID10_Pool| GRP | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 1
| 1:2| 9QK0V0ZB |698GB|RAID10_Pool| GRP | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 2
| 1:3| 9QK0HQ9V |698GB| --
| GLS | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 3
| 1:4| 9QK0QCGS |698GB| --
| UNA | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 4
| 1:5| 9QK0HQ74 |698GB| --
| UNA | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 5
| 1:6| 9QK0QCEQ |698GB| --
| UNA | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 6
| 2:1| 9QK0SWEJ |698GB|RAID10_Pool| GRP | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 7
| 2:2| 9QK0QCJB |698GB|RAID10_Pool| GRP | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 8
| 2:3| 9QK0QC50 |698GB|RAID10_Pool| GRP | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 9
| 2:4| 9QJ1NG5W |931GB| --
| UNA | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 10
| 2:5| 9QK0SWLY |698GB| --
| UNA | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 11
| 2:6| 9QK0QC85 |698GB|RAID10_Pool| GRP | OK
| Online
| 1
| 1
| 7200| BC1D
|
|______|____|__________|_____|___________|_____|_____|___________|____|____|_____|________|
Drive E:T is Enclosure:Tray; tray numbers start at 1, and tray 1 is the uppermost tray.
Usage:
UNA=unassigned
GRP/SGR=current/stale group member
FOR=foreign
GLS/SGS=current/stale global spare
CBG/SCG=current/stale auto-copy-back global spare
State:
OK=healthy
M=missing
P=PFA predicted failure
U=unreliable (M/P/U can be combined)
INI=initialized
UNS=unsupported (non-IBM) drive PM=path missing
IMD=incompatible metadata with this software version; either assimilate drive
or update controller firmware.
UNF=firmware version unsupported for drive
What to do next
If the problem is not resolved, collect the logs and contact IBM.
Removing and reinserting an active controller
You can resolve some software problems associated with an IBM BladeCenter S
SAS RAID Controller Module by removing and reinserting the same RAID
Controller without significant interruption to the server.
Chapter 11. Troubleshooting and support
173
Summary of Contents for BladeCenter S SAS RAID Controller Module
Page 2: ......
Page 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Page 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Page 209: ...Taiwan Class A compliance statement Notices 199...
Page 215: ......
Page 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...