5322
Drive carrier
tray_ID
is not qualified as a replacment. No spare tray assignment will be performed.
Explanation:
Replacement tray is not qualified. This alert indicates that replacement drive detection has been
disabled for this group.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response:
Acknowledge to clear the alert immediately. Assign a replacement spare drive manually.
9300
RAID system down - Unsupported drive
drive_ID
detected
Explanation:
The system entered service mode because unsupported drives were detected on boot-up.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail. Alert clears when the unsupported drive is removed.
Operator response:
Remove the unsupported drive.
9302
Drive
drive_ID
not accessible, please restore connectivity or acknowledge drive group
group_ID
disorderly dismount with potential indeterminate data loss.
Explanation:
The specified drive has no usable paths and is contributing to the specified mounted drive group not
being viable.
Note:
If this condition is detected in power fail recovery and Auto Ack Pending Non-Viable is enabled, alert 9406 is
generated for the group and this alert is not generated for each missing drive group member drive.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail. Alert clears when one of the following events occurs:
v
The specified drive is discovered in the system. (It might not be usable by the group.)
v
Enough drives are discovered to make group viable (not including this drive).
v
The drive group is deleted.
v
One or more drive group members are failed as unreliable such that the group cannot become viable even if this
drive is reconnected.
Operator response:
Acknowledge to clear the alert immediately. Restore the missing drive.
9303
Global spare drive
drive_ID
has been orderly dismounted due to enclosure
enclosure_ID
fault
condition.
Explanation:
Forced orderly dismount due to enclosure critical environmentals.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response:
Acknowledge to clear the alert immediately.
5322 • 9303
138
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
Summary of Contents for BladeCenter S SAS RAID Controller Module
Page 2: ......
Page 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Page 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Page 209: ...Taiwan Class A compliance statement Notices 199...
Page 215: ......
Page 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...