4200
Battery missing
Explanation:
Configuration supports a battery, but no battery is detected by the SES controller.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when a battery is inserted.
Operator response:
Insert a battery (see “Replacing a Battery Backup Unit” on page 177).
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
4201
Battery
battery_ID
product data memory inaccessible
Explanation:
BBU flash device is inaccessible
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. This alert persists until BBU flash device is functional.
Operator response:
Replace the battery (see “Replacing a Battery Backup Unit” on page 177).
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
5200
Controller
controller_ID
reports RAID system 72-hour battery reserve unavailable
Explanation:
No single controller-battery pair available with 72-hour capacity and controller write cache policy is
enabled.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
notified of this alert by e-mail. Alert clears when a controller-battery pair with 72-hour capacity or controller write
cache policy is enabled.
Operator response:
Do either of the following:
v
Replace the battery (see “Replacing a Battery Backup Unit” on page 177).
v
Wait for the battery to charge.
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
5201
Battery
battery_ID
firmware mismatch exists
Explanation:
When the system boots up or a battery is inserted, the controller checks the battery firmware level. If
the firmware does not match the expected version, the controller automatically performs a firmware update. This
alert indicates that a firmware mismatch was detected, but was not corrected because the battery firmware update
failed.
System action:
the operator is notified of this alert by e-mail. Alert clears if the battery is removed.
Operator response:
Reinsert or replace the battery (see “Replacing a Battery Backup Unit” on page 177).
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
4200 • 5201
Chapter 11. Troubleshooting and support
127
Summary of Contents for BladeCenter S SAS RAID Controller Module
Page 2: ......
Page 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Page 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Page 209: ...Taiwan Class A compliance statement Notices 199...
Page 215: ......
Page 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...