9408
Drive group
group_ID
unavailable during powerfail recovery - Reconnect drive(s)
drive_list
if missing
or acknowledge indeterminate data loss to proceed.
Explanation:
With "Auto Ack Pending Non-Viable" disabled, a PFR drive group was not found during PFR drive
discovery because all drives were missing or defunct.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when at least one member drive of the missing drive group is discovered.
Operator response:
Acknowledge to clear the alert immediately. Insert one or more of the missing drives.
9409
JBOD pass-through drive missing during powerfail recovery. To proceed, acknowledge
indeterminate data loss for Host:LUN
LUN
, or insert missing drive
drive_ID
.
Explanation:
With "Auto Ack Pending Non-Viable" disabled, a PFR JOBD drive was not found during PFR drive
discovery. Dirty cache exists for the corresponding volume.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when the missing JBOD drive is discovered.
Operator response:
Acknowledge to clear the alert immediately. Insert the missing JBOD drive.
9410
Drive group
group_ID
was disorderly dismounted during power fail recovery due to unavailable
drive(s)
drive_list
.
Explanation:
Drive group is non-viable during PFR due to missing or defunct drives. "Auto Ack Pending
Non-Viable" is enabled.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail.
Operator response:
Acknowledge to clear the alert immediately.
9411
Drive group
group_ID
is non-viable due to unusable drive(s)
drive_list
. Acknowledge to dismount
associated volumes.
Explanation:
System is operational (not in warm boot) and this group is on the MG list but is not viable due to one
or more unreliable drives.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail.
Operator response:
Acknowledge to clear the alert immediately.
Note:
Acknowledging the alert causes the affected drive group to be removed from the MG list.
9408 • 9411
144
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
Summary of Contents for BladeCenter S SAS RAID Controller Module
Page 2: ......
Page 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Page 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Page 209: ...Taiwan Class A compliance statement Notices 199...
Page 215: ......
Page 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...