| Msg: Drive 01:03 ready for removal
|
|=========================================================================================|
| 2300
| 17 | 20090915141522 | 0
| Info
|5005076b0741417f| 0
| Unmasked |
|-----------------------------------------------------------------------------------------|
| Msg: Drive 01:04 ready for removal
|
|=========================================================================================|
| 2300
| 18 | 20090915141522 | 0
| Info
|5005076b0741417f| 0
| Unmasked |
|-----------------------------------------------------------------------------------------|
| Msg: Drive 01:05 ready for removal
|
| 2300
| 16 | 20090915141522 | 0
| Info
|5005076b0741417f| 0
| Unmasked |
|-----------------------------------------------------------------------------------------|
| Msg: Drive 01:06 ready for removal
|
|=========================================================================================|
9.
Verify the Amber Fault LED is on and in the SOLID state for the DSM that is
being replaced and for each disk drive inside the DSM. For information on
LED states, see “Understanding LEDs” on page 97.
10.
Enter
list drive
and press Enter to list the drive summary for each disk
drive configured in the storage pool. In the DSM that you are replacing,
ensure that the mount state of all the disk drives are in the service state.
<CLI> list drive
Current Machine Local Time: 09/15/2009 02:17:29 PM
________________________________________________________________________________________
|Drive#| E:T |SerialNo| Cap | Pool
|Usage|State|Mount State|Ctl0|Ctl1| RPM |FW level|
|______|_____|________|_____|___________|_____|_____|___________|____|____|_____|________|
| 0
| 1:1 |9QK0SWLM|698GB| --
| UNA | OK
|Service
| 1
| 1
| 7200| BC1D
|
| 1
| 1:2 |9QK0V0ZB|698GB| --
| UNA | OK
|Service
| 1
| 1
| 7200| BC1D
|
| 2
| 1:3 |9QK0HQ9V|698GB| --
| UNA | OK
|Service
| 1
| 1
| 7200| BC1D
|
| 3
| 1:4 |9QK0QCGS|698GB| --
| UNA | OK
|Service
| 1
| 1
| 7200| BC1D
|
| 4
| 1:5 |9QK0HQ74|698GB| --
| UNA | OK
|Service
| 1
| 1
| 7200| BC1D
|
| 5
| 1:6 |9QK0QCEQ|698GB| --
| UNA | OK
|Service
| 1
| 1
| 7200| BC1D
|
| 6
| 2:1 |9QK0SWEJ|698GB|RAID10_Pool| GRP | OK
|Online
| 1
| 1
| 7200| BC1D
|
| 7
| 2:2 |9QK0QCJB|698GB|RAID10_Pool| GRP | OK
|Online
| 1
| 1
| 7200| BC1D
|
| 8
| 2:3 |9QK0QC50|698GB|RAID10_Pool| GRP | OK
|Online
| 1
| 1
| 7200| BC1D
|
| 9
| 2:4 |9QJ1NG5W|931GB| --
| UNA | OK
|Online
| 1
| 1
| 7200| BC1D
|
| 10
| 2:5 |9QK0SWLY|698GB| --
| UNA | OK
|Online
| 1
| 1
| 7200| BC1D
|
| 11
| 2:6 |9QK0QC85|698GB|RAID10_Pool| GRP | OK
|Online
| 1
| 1
| 7200| BC1D
|
|______|_____|________|_____|___________|_____|_____|___________|____|____|_____|________|
Drive E:T is Enclosure:Tray; tray numbers start at 1, and tray 1 is the uppermost tray.
Usage:
UNA=unassigned
GRP/SGR=current/stale group member
FOR=foreign
GLS/SGS=current/stale global spare
CBG/SCG=current/stale auto-copy-back global spare
State:
OK=healthy
M=missing
P=PFA predicted failure
U=unreliable (M/P/U can be combined)
INI=initialized
UNS=unsupported (non-IBM) drive
PM=path missing
IMD=incompatible metadata with this software version; either assimilate drive
or update controller firmware.
UNF=firmware version unsupported for drive
11.
Enter
list pool
and press Enter to list the pool summary for each storage
pool. Ensure that the state of the storage pool is online and viable.
<CLI> list pool
Current Machine Local Time: 09/15/2009 02:17:49 PM
_________________________________________________________________________________________
|Pool#|ID|Name
|RaidType|OwnerCtlr|TotalCap|AvailCap|Status
|State|Degraded|
|_____|__|___________|________|_________|________|________|________________|_____|________|
| 0
| 1|RAID10_Pool| 10
| Slot 1
| 2095GB | 1975GB |Degraded
| ONV | Yes
|
|
|
|
|
|
|
|
|-InTransition
|
|
|
|_____|__|___________|________|_________|________|________|________________|_____|________|
State: OFN/SN=Offline Non-viable/Service Non-viable
ONF/OFF/SF=Online Failed/Offline Failed/ Service Failed
Chapter 11. Troubleshooting and support
171
Summary of Contents for BladeCenter S SAS RAID Controller Module
Page 2: ......
Page 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Page 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Page 209: ...Taiwan Class A compliance statement Notices 199...
Page 215: ......
Page 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...