<CLI> hostlun -map -volume Raid10_Pool:r10_vol_7 -permission rw -wwn 500062b00007e569
-name CliHost1 -lun 7
Working ...
Host LUN 7 for host 500062b00007e569 and host name CliHost1 mapped to volume ’r10_vol_7’
in ’Raid10_Pool’
<CLI> hostlun -map -volume Raid10_Pool:r10_vol_6 -permission rw -wwn 500062b00007e569
-name CliHost1 -lun 8
Working ...
Host LUN 8 for host 500062b00007e569 and host name CliHost1 mapped to volume ’r10_vol_6’
in ’Raid10_Pool’
<CLI> hostlun -map -volume Raid10_Pool:r10_vol_5 -permission rw -wwn 500062b00007e569
-name CliHost1 -lun 9
Working ...
Host LUN 9 for host 500062b00007e569 and host name CliHost1 mapped to volume ’r10_vol_5’
in ’Raid10_Pool’
11.
Log into the host server and scan for hardware changes to allow for the host
to recognized the second path.
12.
Log into the host server and verify the second path is operational.
13.
At the
<CLI>
prompt, enter
host –get
and press Enter to verify the host
mappings of the second WWN.
<CLI> host -get
HostWWN
500062b00007e568,
HostName
Blade_Bay_1
:
LUNs Mapped :
___________________________________________________________
|
LUN
|
Permission
|
Volume
|
|_________|_____________________|___________________________|
|
0|
ACCESS_READWRITE|
Raid10_Pool:r10_vol_1|
|
4|
ACCESS_READWRITE|
Raid10_Pool:r10_vol_10|
|
3|
ACCESS_READWRITE|
Raid10_Pool:r10_vol_4|
|
2|
ACCESS_READWRITE|
Raid10_Pool:r10_vol_3|
|
1|
ACCESS_READWRITE|
Raid10_Pool:r10_vol_2|
|
5|
ACCESS_READWRITE|
Raid10_Pool:r10_vol_9|
|
6|
ACCESS_READWRITE|
Raid10_Pool:r10_vol_8|
|
7|
ACCESS_READWRITE|
Raid10_Pool:r10_vol_7|
|
8|
ACCESS_READWRITE|
Raid10_Pool:r10_vol_6|
|
9|
ACCESS_READWRITE|
Raid10_Pool:r10_vol_5|
|_________|_____________________|___________________________|
HostWWN
500062b00007e569,
HostName
CliHost1
:
LUNs Mapped :
___________________________________________________________
|
LUN
|
Permission
|
Volume
|
|_________|_____________________|___________________________|
|
0|
ACCESS_READWRITE|
Raid10_Pool:r10_vol_1|
|
1|
ACCESS_READWRITE|
Raid10_Pool:r10_vol_2|
|
2|
ACCESS_READWRITE|
Raid10_Pool:r10_vol_3|
|
3|
ACCESS_READWRITE|
Raid10_Pool:r10_vol_4|
|
4|
ACCESS_READWRITE|
Raid10_Pool:r10_vol_10|
|
5|
ACCESS_READWRITE|
Raid10_Pool:r10_vol_9|
|
6|
ACCESS_READWRITE|
Raid10_Pool:r10_vol_8|
28
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
Summary of Contents for BladeCenter S SAS RAID Controller Module
Page 2: ......
Page 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Page 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Page 209: ...Taiwan Class A compliance statement Notices 199...
Page 215: ......