1301
Drive
drive_ID
failure detected - Previous drive status was unassigned
Explanation:
Drive failure condition caused controller to fail an unassigned, foreign, or IM drive.
System action:
Drive mount state is set to DISMOUNTED. By default, the SAS RAID Module system information
indicator is turned on and the operator is notified of this alert by e-mail. The alert clears when the drive is removed.
Operator response:
Replace the failed drive (see “Replacing a failed drive” on page 167).
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
1303
Drive
drive_ID
reports predicted failure - Current drive status is
[
inuse
|
spare
]
Explanation:
PFA detected.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when the drive is removed.
Operator response:
Replace the drive (see “Replacing a failed drive” on page 167).
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
1304
Drive
drive_ID
reports predicted failure - Current drive status is unassigned
Explanation:
PFA detected.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
notified of this alert by e-mail. Alert clears when the drive is removed.
Operator response:
Replace the drive (see “Replacing a failed drive” on page 167).
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
1305
Drive
drive_ID
failure detected - Primary disk port unusable, previous drive status was
[
inuse
|
spare
]
Explanation:
Drive failure process initiated on a drive because of unreliable connectivity on servicer drive port of
assigned drive. Possible causes:
v
Unusable error threshold exceeded.
v
Persistent logged out condition.
System action:
If drive is redundant or spare, the drive is failed and alert 1300 is generated. By default, the SAS
RAID Module system information indicator is not turned on and the operator is notified of this alert by e-mail. Alert
clears when the drive is removed.
Operator response:
Replace the failed drive (see “Replacing a failed drive” on page 167).
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
1307
Drive
drive_ID
error condition detected - Secondary disk port unusable, current drive status
[
inuse
|
spare
|
unassigned
]
Explanation:
Drive failure process initiated on a drive because of unreliable connectivity on servicer drive port of
assigned drive. Possible causes:
v
Unusable error threshold exceeded.
v
Persistent logged out condition.
The drive is not failed or dismounted based on secondary port status.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when the drive is removed.
Operator response:
Replace the drive (see “Replacing a failed drive” on page 167)..
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
1301 • 1307
Chapter 11. Troubleshooting and support
133
Summary of Contents for BladeCenter S SAS RAID Controller Module
Page 2: ......
Page 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Page 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Page 209: ...Taiwan Class A compliance statement Notices 199...
Page 215: ......
Page 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...