Note: If you did not complete this entire procedure (because you did not have
the supply, for example) scroll to NO, and press the Enter key.
15. Press the Menu/Exit key to exit menu mode.
16. Press the Start key to continue printing.
17. Dispose of the used fuser unit.
Replacing the Cleaner Unit
Replace the cleaner unit when the CLEANER UNIT: REPLACE SOON or
CLEANER UNIT: REPLACE NOW message appears. To replace the cleaner unit,
do the following:
1. Press the Stop key (if the printer is READY) to temporarily stop any current
print jobs and to make the printer NOT READY.
2. Press the Menu/Exit key to enter menu mode.
3. Scroll to SUPPLIES on the main menu, and press the Enter key. Enter the key
operator password, if prompted.
4. Scroll to CLEANER UNIT, and press the Enter key.
5. The CHANGE NOW message appears. (The PLEASE WAIT... message may
occur first.)
Note: If you selected SUPPLIES by mistake and do not want to begin a
replacement procedure, scroll to CANCEL CHANGE, and press the Enter key.
6. Open the front cover.
7. Unlock the EP module; turn the two lock levers clockwise and the paper feed
module handle counterclockwise to the RELEASE position.
8. Pull out the EP module; pull the EP module handle.
Chapter 6. Maintaining the Printer