453
Appendix
Axis-Specific Parameters
No.
Parameter name
Default value
(Reference)
Input range
Unit
Remarks
67 Short-cut control selection
for rotational movement
axis (linear movement
axis)
0
0 ~ 5
Reference only
for SCARA axes
(axes 1 to 4)
0: Do not select, 1: Select (Valid only in the index
mode AND when an incremental encoder is used)
* Valid for linear movement axes (axes 5 and 6
(6-axis type)) only.
(Main application version 0.12 or later)
68 Mode selection for linear
movement axis (linear
movement axis)
0
0 ~ 5
Reference only
for SCARA axes
(axes 1 to 4)
0: Normal, 1: Infinite-stroke mode (Note:
Positioning boundary applies. This parameter can
be specified only when an incremental encoder is
used.)
* Valid for linear movement axes (axes 5 and 6
(6-axis type)) only.
(Main application version 0.12 or later)
69 (For extension)
0
~
70 For future extension
0
Reference only
For adjustment by the manufacturer
71 For future extension
0
Reference only
For adjustment by the manufacturer
72 For future extension
(Change prohibited)
0
Reference only
DRVVR
For adjustment by the manufacturer
73 For future extension
(Change prohibited)
0
Reference only
DRVVR
For adjustment by the manufacturer
74 For future extension
0
Reference only
For adjustment by the manufacturer
75 For future extension
0
Reference only
For adjustment by the manufacturer
76 For future extension
(Change prohibited)
0
0H ~
FFFFFFFFH
(Change prohibited)
0: P21 = Phase-Z evacuation distance at
incremental home return
P12 = Ideal phase-Z position coordinate
1: Automatically acquire P32 even when P33 = 0.
P33 = 0 “= Actual distance”
P21 = Offset travel distance at home return
P12 = Coordinate after offset travel at home
return
P26 is invalid (to make adjustment easy).
77 Synchro S pulse of linear
movement axis
0,
0,
0,
0,
3,
3
0 ~ 99999
Reference only
for SCARA axes
(axes 1 to 4)
Pulse
* Valid for linear movement axes (axes 5 and 6
(6-axis type)) only.
(Main application version 0.12 or later)
78 Maximum takeoff
command amount
0
-3000 ~ 3000
0.001 mm Maximum lift command amount before brake
unlock (Input with sign)
(Suppression of momentary drop upon servo ON
when a heavy object is placed)
* Important: Input using the same sign as the
rising coordinate direction. (0.100
mm to 0.500 mm in absolute value
as a guideline)
* The servo-ON check time (axis-specific
parameter No. 30) must also be extended
(approx. 1000 to 1500 msec) to provide a
sufficient time for rise-direction torque to
follow. (This setting is valid only when a brake
is equipped.)
79 Actual takeoff check
distance
5
0 ~ 3000
0.001 mm Absolute value input
80 Maximum forced-feed
range of linear movement
axis
0
0 ~ 9999
Reference only
for SCARA axes
(axes 1 to 4)
0.001 mm For reduction of settling time.
(Invalid range if “0” is set)
(Approx. 1.000 mm as a guideline)
* Valid for linear movement axes (axes 5 and 6
(6-axis type)) only.
(Main application version 0.12 or later)
81 Minimum forced-feed
range of linear movement
axis
0,
0,
0,
0,
200,
200
0 ~ 9999
Reference only
for SCARA axes
(axes 1 to 4)
0.001 mm * Valid for linear movement axes (axes 5 and 6
(6-axis type)) only.
(Main application version 0.12 or later)
454
Appendix
Axis-Specific Parameters
No.
Parameter name
Default value
(Reference)
Input range
Unit
Remarks
82 Middle forced-feed range
of linear movement axis
0,
0,
0,
0,
600,
600
0 ~ 9999
Reference only
for SCARA axes
(axes 1 to 4)
0.001 mm * Valid for linear movement axes (axes 5 and 6
(6-axis type)) only.
(Main application version 0.12 or later)
83 Cancellation of absolute
synchro slave-axis
coordinate initialization
(linear movement axis)
0
0 ~ 5
Reference only
for SCARA axes
(axes 1 to 4)
Valid only for the synchro slave axis.
* Valid for linear movement axes (axes 5 and 6
(6-axis type)) only.
(Main application version 0.15 or later)
84 Maximum synchronization
correction speed of
synchro slave axis (linear
movement axis)
0,
0,
0,
0,
5,
5
0 ~ 100
Reference only
for SCARA axes
(axes 1 to 4)
mm/sec Maximum travel speed for synchronization
position correction of the slave axis.
Valid only for the synchro slave axis.
* Valid for linear movement axes (axes 5 and 6
(6-axis type)) only.
* Note: Not limited by the safety speed.
(Main application version 0.15 or later)
85 Acceleration/deceleration
at movement to absolute
reset position/home return
0,
0,
15,
0,
15,
15
1 ~ 300
Reference only
for SCARA axes
(axes 1 to 4)
0.01 G, (Used for SCARA axis 3 (Zc) and linear
movement axes (axes 5 and 6 (6-axis type)))
86 Zone 1 MAX of linear
movement axis
0
-99999999 ~
99999999
Reference only
for SCARA axes
(axes 1 to 4)
0.001 mm Valid only when MAX > MIN. * Must be inside
the range for at least 3 msec.
* Valid for linear movement axes (axes 5 and 6
(6-axis type)) only.
(Main application version 0.15 or later)
87 Zone 1 MIN of linear
movement axis
0
-99999999 ~
99999999
Reference only
for SCARA axes
(axes 1 to 4)
0.001 mm Valid only when MAX > MIN. * Must be inside
the range for at least 3 msec.
* Valid for linear movement axes (axes 5 and 6
(6-axis type)) only.
(Main application version 0.15 or later)
88 Zone 1 output number for
linear movement axis
0
0 ~ 899
Reference only
for SCARA axes
(axes 1 to 4)
Physical output port or global flag (Output is
invalid if “0” is input; multiple specification is
invalid)
* Valid for linear movement axes (axes 5 and 6
(6-axis type)) only.
(Main application version 0.15 or later)
89 Zone 2 MAX of linear
movement axis
0
-99999999 ~
99999999
Reference only
for SCARA axes
(axes 1 to 4)
0.001 mm Valid only when MAX > MIN. * Must be inside
the range for at least 3 msec.
* Valid for linear movement axes (axes 5 and 6
(6-axis type)) only.
(Main application version 0.15 or later)
90 Zone 2 MIN of linear
movement axis
0
-99999999 ~
99999999
Reference only
for SCARA axes
(axes 1 to 4)
0.001 mm Valid only when MAX > MIN. * Must be inside
the range for at least 3 msec.
* Valid for linear movement axes (axes 5 and 6
(6-axis type)) only.
(Main application version 0.15 or later)
91 Zone 2 output number for
linear movement axis
0
0 ~ 899
Reference only
for SCARA axes
(axes 1 to 4)
Physical output port or global flag (Output is
invalid if “0” is input; multiple specification is
invalid)
* Valid for linear movement axes (axes 5 and 6
(6-axis type)) only.
(Main application version 0.15 or later)
92 Zone 3 MAX of linear
movement axis
0
-99999999 ~
99999999
Reference only
for SCARA axes
(axes 1 to 4)
0.001 mm Valid only when MAX > MIN. * Must be inside
the range for at least 3 msec.
* Valid for linear movement axes (axes 5 and 6
(6-axis type)) only.
(Main application version 0.15 or later)
457
Summary of Contents for X-SEL PX
Page 1: ...Operation ManualSeventh Edition X SEL Controller PX QX Type Tenth Edition ...
Page 2: ......
Page 8: ......
Page 14: ......
Page 410: ...383 Appendix 386 ...
Page 452: ...425 Appendix 5 428 ...
Page 559: ......