283
Part 4 Commands
SCHA (Set end character)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional SCHA
Character
code
Prohibited CP
[Function] Set the end character to be used by a READ or WRIT command.
Any character from 0 to 255 (character code used in BASIC, etc.) can be specified.
[Example] Refer to the sections on READ and WRIT commands.
284
Part 4 Commands
1.19 String Operation
SCPY (Copy character string)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional SCPY Column
number
Column
number,
character literal
CC
[Function] Copy the character string in the column specified in operand 2 to the column specified in
operand 1.
Copy will be performed for the length set by a SLEN command.
If a character literal is specified in operand 2, copy will be performed for the entire length of
the literal.
[Example]
SCPY 1
‘ABC’ Copy ‘ABC’ to column 1.
SLEN
10
Set the copying length to 10 bytes.
SCPY
100
200
Copy 10 bytes from column 200 to column 100.