211
Part 4 Commands
DFTL (Dedicated SCARA command: Define tool coordinate system)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional DFTL
Tool coordinate
system number
Position
number
CP
[Function] Set the position data specified in operand 2 as the offset data for the tool coordinate system
specified in operand 1.
The offset data for tool coordinate system corresponding to all SCARA axes will be set in
the position data, but the position data for invalid axes will be set as “zero offset.”
(Note 1)
The tool and load coordinate systems are dedicated SCARA functions.
(Note 2)
Tool coordinate system No. 0 is reserved for a condition where no tool offset is applicable.
Therefore, setting this coordinate system number will generate an "Error No. B71:
Coordinate system number error."
(Note 3)
GRP commands are invalid with respect to this command.
[Example]
DFTL 1
150
Position data
212
Part 4 Commands
SLTL (Dedicated SCARA command: Select tool coordinate system)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional SLTL
Tool coordinate
system number
Prohibited CP
[Function] Set the value specified in operand 1 as the selected tool coordinate system number.
Refer to 3, "Coordinate System," in Chapter 3 of Part 4.
(Note 1)
The tool and load coordinate systems are dedicated SCARA functions.
(Note 2)
The number declared last in the system becomes valid.
The selected tool coordinate system number will remain valid after the program ends, or
even after reconnection of power if a system-memory backup battery is installed.
(Note 3)
Only one tool coordinate system number can be selected in the system.
(Note 4)
Expressly declare SLTL in the program to prevent problems that may occur when the
coordinate system number changed via the PC software or teaching pendant was not
returned to the original setting.
(Set SLTL = 0, if tool coordinate system is not used.)
215