135
Part 4 Commands
RC Gateway Function Commands (Controllers with Gateway Function Only)
* For the RC gateway function commands, refer to “Operation Manual for X-SEL Controller P/Q/PX/QX
RC Gateway Function.”
Operation type in the output field
CC: Command was executed successfully,
ZR: Operation result is zero, PE: Operation is complete,
CP: Command part has passed, TU: Time up
EQ: Operand 1 = Operand 2, NE: Operand 1
Operand 2,
GT: Operand 1 > Operand 2, GE: Operand 1
Operand 2,
LT: Operand 1 < Operand 2, LE: Operand 1
Operand 2
RC position
data use mode
Category Condition Command In X-
SEL In RC
Operand 1
Operand 2
Output
Function
Optional RPGT
X
RC axis number
Position number
CC
Assign RC axis position to
variable 199
Optional RPPT
X
RC axis number
Position number
CP
Assign variable 199 to RC axis
position
Optional RPCR
X
RC axis number
Variable number
CP
Clear RC axis position data
Optional RPCP
X
RC axis number
Variable number
CP
Copy RC axis position data
Optional RPRD
X
Position number
Prohibited
CP
Read current RC axis position
Optional RPRQ
RC axis number
Variable number
CP
Read current RC axis position (1
axis, direct)
Optional RPVL
X
RC axis number
Position number
CP
Assign variable 199 to RC axis
position speed
Optional RPAD
X
RC axis number
Position number
CP
Assign variable 199 to RC axis
position acceleration/deceleration
Optional RPIP
X
RC axis number
Position number
CP
Assign variable 199 to RC axis
position positioning band
Optional RPTQ
X
RC axis number
Position number
CP
Assign variable 199 to RC axis
position current-limiting value
Optional RGVL
X
RC axis number
Position number
CP
Assign RC axis position speed to
variable 199
Optional RGAD
X
RC axis number
Position number
CP
Assign RC axis position
acceleration/deceleration to
variable 199
Optional RGIP
X
RC axis number
Position number
CP
Assign RC axis position
positioning band to variable 199
RC axis
position
operation
Optional RGTQ
X
RC axis number
Position number
CP
Assign RC axis position current-
limiting value to variable 199
Optional RAXS
Axis pattern, upper Axis pattern,
lower
CP
Set RC axis pattern
Optional RSON
Prohibited
Prohibited
PE
Turn RC axis servo ON
Optional RSOF
Prohibited
Prohibited
PE
Turn RC axis servo OFF
Optional RHOM
Prohibited
Prohibited
PE
Return RC axis to its home
Optional RMVP
Position number
Prohibited
PE
Move by RC axis position
specification
Optional RMPI
X
Position number
Prohibited
PE
Incremental move by RC axis
position specification
Optional RMVD
X
RC axis number
Variable number
PE
Move by RC axis direct
specification
Optional RMDI
X
RC axis number
Variable number
PE
Incremental move by RC axis
direct specification
Optional RPUS
X
RC axis number
Position number
PE
Move by RC axis push-motion
operation
RC
actuator
control
command
Optional RSTP
Prohibited Prohibited PE
Decelerate RC axis to stop
RC axis
information
acquisition
Optional RCST
Variable number
RC axis number
PE
Get RC axis status
136
Part 4 Commands
2.
Alphabetical Order
Operation type in the output field
CC: Command was executed successfully,
ZR: Operation result is zero, PE: Operation is complete,
CP: Command part has passed, TU: Time up
EQ: Operand 1 = Operand 2, NE: Operand 1
Operand 2,
GT: Operand 1 > Operand 2, GE: Operand 1
Operand 2,
LT: Operand 1 < Operand 2, LE: Operand 1
Operand 2
Command Page Condition
Operand 1
Operand 2
Output
Function
A
ABPG
174
Optional Stop program number
(Stop program number)
CC
Stop other program
ACC
195
Optional Acceleration
Prohibited
CP
Set acceleration
ACCS
196
Optional Ratio [%]
Prohibited
CP
Set acceleration ratio in PTP operation
(SCARA only)
ACHZ
305
Optional Axis number
Prohibited
CP
Declare arch motion Z-axis
ADD
143
Optional Augend variable
Addend
ZR Add
AEXT
307
Optional (Position number)
Prohibited
CP
Set arch motion composition (SCARA only)
AND
151
Optional AND operand variable
Operand
ZR
Logical AND
ARC
260
Optional Passing position number End position number
PE
Move along arc
ARC2
243
Optional Passing position number End position number
PE
Move along arc 2
ARCC
251
Optional Center position number
Center angle
PE
Move along arc via specification of center
position and center angle
ARCD
249
Optional End position number
Center angle
PE
Move along arc via specification of end
position and center angle
ARCH
315
Optional Position number
Position number
PE
Arch motion
ARCS
247
Optional Passing position number Passing position number
PE
Move along arc three-dimensionally
ATN
149
Optional Inverse tangent
assignment operation
Operand
ZR
Inverse tangent
ATRG
306
Optional Position number
Position number
CP
Set arch trigger
AXST
270
Optional Variable number
Axis number
CP
Get axis status
B
BASE
204
Optional Reference axis number
Prohibited
CP
Set reference axis
BGPA
293
Optional Palletizing number
Prohibited
CP
Declare start of palletizing setting
BGSR
170 Prohibited Declaration subroutine
number
Prohibited
CP
Start subroutine
BTPF
160
Optional Output port, flag
Timer setting
CP
Output OFF pulse
BTPN
159
Optional Output port, flag
Timer setting
CP
Output ON pulse
BT
158
Optional Start output, flag
(End output, flag)
CP
Output, flag [ON, OF, NT]
C
CANC
207
Optional (Input port to abort)
(CANC type)
CP
Declare port to abort
CHPR
317
Optional 0 or 1
Prohibited
CP
Change task level
CHVL
253
Optional Axis pattern
Speed
CP
Change speed (Linear movement axis only)
CIR
259
Optional Passing position 1
number
Passing position 2
number
PE
Move along circle
CIR2
241
Optional Passing position 1
number
Passing position 2
number
PE
Move along circle 2
CIRS
245
Optional Passing position 1
number
Passing position 2
number
PE
Move three dimensionally along circle
CLOS
278
Optional Channel number
Prohibited
CP
Close channel
CLR
142
Optional Start of clear variable
End-of-clear variable
ZR
Clear variable
COS
147
Optional Cosine assignment
variable
Operand
ZR Cosine
CP
154
Optional Comparison variable
Comparison value
EQ NE GT
GE LT LE
Compare
D
DCL
197
Optional Deceleration
Prohibited
CP
Set deceleration
DCLS
198
Optional Ratio [%]
Prohibited
CP
Set acceleration ratio in PTP operation
(SCARA only)
DEG
203
Optional Division angle
Prohibited
CP
Set division angle
DFIF
223 Optional Interference check zone
number
Psition number
CP
Define coordinates of simple interference
check zone (SCARA only)
DFTL
221 Optional Tool coordinate system
number
Psition number
CP
Define tool coordinate system (SCARA only)
DFWK
214 Optional Load coordinate system
number
Psition number
CP
Define load coordinate system (SCARA only)
DIS
208
Optional Distance
Prohibited
CP
Set spline division distance
DIV
144
Optional Dividend variable
Divisor
ZR Divide
DW
264
Optional Comparison variable
Comparison value
CP
Loop [EQ, NE, GT, GE, LT, LE]
139
Summary of Contents for X-SEL PX
Page 1: ...Operation ManualSeventh Edition X SEL Controller PX QX Type Tenth Edition ...
Page 2: ......
Page 8: ......
Page 14: ......
Page 410: ...383 Appendix 386 ...
Page 452: ...425 Appendix 5 428 ...
Page 559: ......