431
Appendix
I/O Parameters
No. Parameter name
Default value
(Reference)
Input range
Unit
Remarks
34 Input function selection
004
0
0 ~ 5
0: General-purpose input
1: All servo axis soft interlock (OFF level) (Valid for all
commands other than the servo OFF command)
(Operation is held upon interlock actuation during
automatic operation; operation is terminated upon
interlock in non-AUTO mode)
35 Input function selection
005
0
0 ~ 5
0: General-purpose input, 1: Operation-pause reset
signal (ON edge)
36 Input function selection
006
0
0 ~ 5
0: General-purpose input
1: Operation-pause reset signal (OFF level) (Valid only
during automatic operation)
* Cancel pause when an operation-pause reset
signal is received.
37 Input function selection
007
1
0 ~ 5
0: General-purpose input, 1: Program number specified
for program start (least significant bit)
38 Input function selection
008
1
0 ~ 5
0: General-purpose input, 1: Program number specified
for program start
39 Input function selection
009
1
0 ~ 5
0: General-purpose input, 1: Program number specified
for program start
40 Input function selection
010
1
0 ~ 5
0: General-purpose input, 1: Program number specified
for program start
41 Input function selection
011
1
0 ~ 5
0: General-purpose input, 1: Program number specified
for program start
42 Input function selection
012
1
0 ~ 5
0: General-purpose input, 1: Program number specified
for program start
43 Input function selection
013
1
0 ~ 5
0: General-purpose input
1: Program number specified for program start
2: Error reset (ON edge)
44 Input function selection
014
0
0 ~ 5
0: General-purpose input (Cancel cutoff when the drive-
source cutoff factor is removed)
1: Drive-source cutoff reset input (ON edge) (Valid
when the factor has been removed)
* Drive-source cutoff reset control is not available for
axes whose motor drive power unit is not housed
inside this controller or axes whose drive-source
cutoff circuit is not controlled by this controller.
45 Input function selection
015
0
0 ~ 5
0: General-purpose input
1: Move/return all linear movement axes to the absolute
reset position/home (ON edge) (Each servo must be
turned ON first = I/O parameter No. 32, axis-specific
parameter No. 13)
* Valid only for the 6-axis type.
(Main application version 0.15 or later)
2: Return all incremental linear movement axes to the
home (ON edge) (Each servo must be turned ON
first = I/O parameter No. 32, axis-specific parameter
No. 13)
* Valid only for the 6-axis type.
(Main application version 0.15 or later)
46 Output function selection
300
2
0 ~ 20
0: General-purpose output
1: Output error of operation-cancellation level or higher
(ON)
2: Output error of operation-cancellation level or higher
(OFF)
3: Output error of operation-cancellation level or higher
+ emergency stop (ON)
4: Output error of operation-cancellation level or higher
+ emergency stop (OFF)
47 Output function selection
301
3
0 ~ 20
0: General-purpose output
1: READY output (PIO trigger program can be run)
2: READY output (PIO trigger program can be run and
error of operation-cancellation level or higher is not
present)
3: READY output (PIO trigger program can be run and
error of cold-start level or higher is not present)
432
Appendix
I/O Parameters
No.
Parameter name
Default value
(Reference)
Input range
Unit
Remarks
48 Output function selection
302
2
0 ~ 20
0: General-purpose output
1: Emergency-stop output (ON)
2: Emergency-stop output (OFF)
49 Output function selection
303
0
0 ~ 5
0: General-purpose output
1: AUTO mode output
2: Output during automatic operation (Other
parameter No. 12)
50 Output function selection
304
0
0 ~ 5
0: General-purpose output
1: Output when all valid linear movement axes are at
the home (= 0)
* Valid only for the 6-axis type.
(Main application version 0.15 or later)
2: Output when all valid linear movement axes have
completed home return (coordinates are
confirmed)
* Valid only for the 6-axis type.
(Main application version 0.15 or later)
3: Output when all valid linear movement axes are at
the preset home coordinates
* To move an absolute-encoder linear movement
axis to coordinate 0 or to the preset home
coordinates, use a MOVP command instead of a
HOME command.
* Valid only for the 6-axis type.
(Main application version 0.15 or later)
51 Output function selection
305
0
0 ~ 5
0: General-purpose output
1: For future extension
2: Output when axis-1 servo is ON (System monitor
task output)
3: For future extension
52 Output function selection
306
0
0 ~ 5
0: General-purpose output
1: For future extension
2: Output when axis-2 servo is ON (System monitor
task output)
3: For future extension
53 Output function selection 307
0
0 ~ 5
0: General-purpose output
1: For future extension
2: Output when axis-3 servo is ON (System monitor task
output)
3: For future extension
54 Output function selection 308
0
0 ~ 5
0: General-purpose output
1: For future extension
2: Output when axis-4 servo is ON (System monitor task
output)
3: For future extension
55 Output function selection 309
0
0 ~ 5
0: General-purpose output
1: For future extension
2: Output when axis-5 servo is ON (F-ROM 16-Mbit
version only)
3: For future extension
* The synchro slave axis will follow the synchro master
axis.
* Valid only for the 6-axis type.
56 Output function selection 310
0
0 ~ 5
0: General-purpose output
1: For future extension
2: Output when axis-6 servo is ON (F-ROM 16-Mbit
version only)
3: For future extension
* The synchro slave axis will follow the synchro master
axis.
* Valid only for the 6-axis type.
57 Output function selection 311
0
0 ~ 5
0: General-purpose output, 1 to 3: For future extension
58 Output function selection 312
0
0 ~ 5
0: General-purpose output ,1 to 3: For future extension
59 Output function selection 313
1
0 ~ 5
0: General-purpose output
1: System-memory backup battery voltage-low warning
level or lower
434