139
Part 4 Commands
Operation type in the output field
CC: Command was executed successfully, ZR: Operation result is zero,
PE: Operation is complete, CP: Command part has passed, TU: Time up
EQ: Operand 1 = Operand 2, NE: Operand 1
Operand 2,
GT: Operand 1 > Operand 2, GE: Operand 1
Operand 2,
LT: Operand 1 < Operand 2, LE: Operand 1
Operand 2
Command Page Condition
Operand 1
Operand 2
Output
Function
P
PRED
181
Optional Read axis pattern
Save destination
position number
CP
Read current axis position
PSET
309
Optional Palletizing number
Data
CC
Set palletizing position number directly
PSIZ
188
Optional Size assignment
variable number
CP
Confirm position size
PSLI
301
Optional Offset amount
(Count)
CP
Set zigzag
PSPL
238
Optional Start position number
End position number
PE
Move along spline
PTNG
308
Optional Palletizing number
Variable number
CP
Get palletizing position number
PTPD
221 Optional Prohibited Prohibited CP
Specify current arm as PTP target arm system
(SCARA only)
(Movement of the opposite arm system is prohibited
when the target value cannot be achieved) (No arm
operation)
PTPE
222 Optional Prohibited Prohibited CP
Specify current arm as PTP target arm system
(SCARA only)
(Movement of the opposite arm system is permitted
when the target value cannot be achieved) (No arm
operation)
PTPL
220 Optional Prohibited Prohibited CP
Specify left arm as PTP target arm system (SCARA
only)
(Movement of the opposite arm system is prohibited
when the target value cannot be achieved) (No arm
operation)
PTPR
219 Optional Prohibited Prohibited CP
Specify right arm as PTP target arm system (SCARA
only)
(Movement of the opposite arm system is prohibited
when the target value cannot be achieved) (No arm
operation)
PTRG
303
Optional Position number
Position number
CP
Set palletizing arch triggers (SCARA only)
PTRQ
258
Optional Axis pattern
Ratio
CC
Change push torque limit parameter
PTST
183
Optional Confirmation axis
pattern
Confirmation position
number
CP
Confirm position data
PUSH
239
Optional Target position number Prohibited
PE
Move by push motion
PVEL
184
Optional Speed
Assignment destination
position number
CP
Assign position speed
R
READ
279
Optional Channel number
Column number
CC
Read from channel
RIGH
217 Optional Prohibited Prohibited PE
Change current arm system to right arm
(SCARA only)
(Arm 2 may operate if the current arm system
is the opposite arm)
RSPG
176
Optional Resumption program
number
(Resumption program
number)
CC
Resume program
S
SCHA
283
Optional Character code
Prohibited
CP
Set end character
SCMP
285
Optional Column number
Column number,
character literal
EQ
Compare character strings
SCPY
284
Optional Column number
Column number,
character literal
CC
Copy character string
SCRV
200
Optional Ratio
Prohibited (S-motion
type)
CP
Set sigmoid motion ratio
SEIF
225 Optional Interference check zone
number
0 or 1 or 2 (Error type)
CP
Specify error type for simple interference
check zone (SCARA only)
SGET
286
Optional Variable number
Column number,
character literal
CP
Get character
SIN
146
Optional Sine assignment
variable
Operand
ZR Sine
SLCT
266
Optional Prohibited
Prohibited
CP
Declare start of multi-branching
SLEN
292
Optional Character string length
Prohibited
CP
Set length
SLTL
212 Optional Tool coordinate system
number
Prohibited
CP
Select tool coordinate system (SCARA only)
SLWK
215 Optional Load coordinate system
number
Prohibited
CP
Select load coordinate system (SCARA only)
SOIF
224 Optional Interference check zone
number
Output/global flag
number
CP
Specify output for simple interference check
zone (SCARA only)
140
Part 4 Commands
Operation type in the output field
CC: Command was executed successfully, ZR: Operation result is zero,
PE: Operation is complete, CP: Command part has passed, TU: Time up
EQ: Operand 1 = Operand 2, NE: Operand 1
Operand 2,
GT: Operand 1 > Operand 2, GE: Operand 1
Operand 2,
LT: Operand 1 < Operand 2, LE: Operand 1
Operand 2
Command Page Condition
Operand 1
Operand 2
Output
Function
S
SPUT
287
Optional Column number
Data
CP
Set character
SQR
150
Optional Root assignment
variable
Operand
ZR Root
SSPG
175
Optional Pause program number (Pause program
number)
CC
Pause program
STOP
237
Optional Axis stop pattern
Prohibited
CP
Decelerate and stop axis
STR
288
Optional Column number
Data
CC
Convert character string; decimal
STRH
289
Optional Column number
Data
CC
Convert character string; hexadecimal
SUB
143
Optional Minuend variable
Subtrahend
ZR Subtract
SV
229
Optional Operation axis pattern
Prohibited
PE
Servo [ON, OF]
SYST
272
Optional Variable number
Prohibited
CP
Get system status
T
TAG
169 Prohibited Declaration tag number
Prohibited
CP
Declare jump destination
TAN
148
Optional Tangent assignment
variable
Operand
ZR Tangent
TIMC
156
Optional Program number
Prohibited
CP
Cancel waiting
TIMR
373
Optional Local flag number
Timer setting
CP
Timer relay for ladder
TIMW
155
Optional Wait time
Prohibited
TU Wait
TMLI
257
Optional Position number
Prohibited
PE
Move relatively between positions on tool
coordinate system via interpolation (SCARA
only)
TMPI
256
Optional Position number
Prohibited
PE
Move relatively between positions on tool
coordinate system (SCARA only)
TMRW
281
Optional Read timer setting
(Write timer setting)
CP
Set READ timeout value
TPCD
317 Prohibited 0 or 1
Prohibited
CP
Specify processing to be performed when
input condition is not specified
TRAN
141
Optional Copy destination
variable
Copy source variable
ZR
Copy
TSLP
318 Prohibited Time
Prohibited
CP
Task sleep
V
VAL
290
Optional Variable number
Column number,
character literal
CC
Convert character string data; decimal
VALH
291
Optional Variable number
Column number,
character literal
CC
Convert character string data; hexadecimal
VEL
192
Optional Speed
Prohibited
CP
Set speed
VELS
193 Optional Ratio
Prohibited
CP
Set speed ratio in PTP operation (SCARA
only)
VLMX
199
Optional Prohibited
Prohibited
CP
Specify VLMX speed (Linear movement axis
only)
W
WGHT
227
Optional Mass
(Inertial moment)
CP
Set tip load mass/inertial moment
WH
267 Prohibited Comparison variable
Comparison value
CP
Branch value [EQ, NE, GT, GE, LT, LE]
WRIT
282
Optional Channel number
Column number
CC
Output to channel
WS
268 Prohibited Column number
Column number,
character literal
CP
Branch character string [EQ, NE]
WT
161
Optional I/O, flag
(Wait time)
TU
Wait for I/O, flag [ON, OF]
WZFA
276
Optional Zone number
Axis pattern
CP
Wait for zone OFF, with AND (Linear
movement axis only)
WZFO
277
Optional Zone number
Axis pattern
CP
Wait for zone OFF, with OR (Linear
movement axis only)
WZNA
274
Optional Zone number
Axis pattern
CP
Wait for zone ON, with AND (Linear
movement axis only)
WZNO
275
Optional Zone number
Axis pattern
CP
Wait for zone ON, with OR (Linear movement
axis only)
143