18. Movement by Position Number Specification
Description
Read an external BCD code input as a position number to move the actuator.
How to Use
Use an INB command to read a position number as a BCD code via an input port. A position number
consisting of up to three digits can be specified.
Flow Chart Input
assignment Output
Application Program
Start
Default setting
Start input
Read a BCD
Movement complete
signal turns OFF
Move to the
specified position
number
Movement complete
signal turns ON
Port
Description
Completion of movement by 303
1
Start input
15
Position specification 1
16
Position specification 2
17
Position specification 4
18
Position specification 8
19
Position specification 10
20
Position specification 20
21
Position specification 40
22
Position specification 80
23
Position specification 100
24
Position specification 200
25
Position specification 400
26
Position specification 800
Set a speed.
Destination of GOTO
Wait for a start input.
Read a position number.
Moving complete signal turns OFF
Move to the position number.
Movement complete signal turns ON
Jump to TAG1.
402
Appendix
19. Movement by External Position Data Input (for Linear Axes)
Description
Receive from the host device an absolute value indicating the position data to be used in the movement,
and move the actuator accordingly.
Example of Use
Use an INB command to read position data as a BCD via an input port. The BCD value to be received has
four digits, with the last digit specifying a decimal place. Axis 1 is moved.
Example: If the value of BCD is “1234,” the axis will move to the position at 123.4 mm.
Flow Chart Input
assignment Output
Application Program
Comment
Home return
Set a speed.
Destination of GOTO
Wait for a start input.
Read the position to move to.
Copy to a real variable to add a decimal point.
Divide by 10 to add a decimal point.
Assign the data to axis 1 corresponding to position
No. 1000
.
Moving complete signal turns OFF
Move to the assigned position.
Movement complete signal turns ON
Jump to TAG1.
Port
Description
Completion of movement by 303
1
Start input
15
0.1 mm
16
0.2 mm
17
0.4 mm
18
0.8 mm
19
1 mm
20
2 mm
21
4 mm
22
8 mm
23
10 mm
24
20 mm
25
40 mm
26
80 mm
27
100 mm
28
200 mm
29
400 mm
30
800 mm
Start
Default setting
Start input
Read a BCD
Movement complete
signal turns OFF
Movement complete
signal turns ON
Move to the
specified position
405