Password:
hpinvent
•
Password Confirm:
hpinvent
5.
For Account Privileges, select
Yes
for all listed privileges.
6.
Press
F10
.
7.
Repeat these steps for each HP StoreAll node.
NOTE:
iLO creates a default, self-signed certificate for SSL connections, but it can result in an
"invalid certificate" error when accessing iLO web pages. You can safely ignore this error and
continue with the login process. If your environment requires the use of a valid certificate, see
"Administering SSL certificates" in the HP iLO 4 User Guide (available at
http://
h20628.www2.hp.com/km-ext/kmcsdirect/emr_na-c03334051-10.pdf
) for information about
importing certificates.
Verifying LUNs and component firmware
Before your run the StoreAll Installation wizard, you must verify LUNs and component firmware.
Verifying LUNs
Verify volumes by entering the following command on one node in the couplet:
hpsp_spt -lv
Verify that the name of each LUN is unique. If not unique, run the following command on one node
in the couplet, which fixes the names:
hpsp_spt -fn
NOTE:
You only need to run this command if you are assembling the hardware components on
site. If you have a complete factory-assembled rack, do not run this command.
Verifying component firmware
To ensure you are running the latest firmware:
1.
Verify the firmware and save the output to a file for review verification later.
•
Run this command on one node in each couplet:
hpsp_fmt -fr storage >/local/fwstorage.out
NOTE:
You do not need to run
hpsp_fmt -fr storage
on HP StoreAll 8200 systems.
•
Run this command on the servers:
hpsp_fmt -fr server >/local/fwserver.out
2.
Create a hardware report. The hardware report will show status information about both servers
and storage.
•
Run this command on every server/node, and if you run this on multiple servers, be sure
to create a unique file name each time:
hpspmonControl --server --filter text >/local/monsvr_x.out
Run this command to show the output on the screen:
more /local/monsvr.out
•
Run this command on one node in a couplet:
hpspmonControl --storage --filter text >/local/storage_x.out
Run this command to show the output on the screen:
76
Installing the HP StoreAll OS Software and configuring the HP StoreAll Storage system