DCFM Professional User Manual
209
53-1001773-01
SNMP trap and informs registration and forwarding
8
Enabling SNMP informs
NOTE
SNMP Informs is only supported on Fabric OS 6.3 or later switches discovered through SNMP v3. For
information about discovery through SNMP v3, refer to
“Discovering fabrics”
on page 37.
You can enable SNMP informs on all Informs-capable Fabric OS switches.
To enable Informs, complete the following steps.
1. Select Monitor > SNMP Setup.
The SNMP Setup dialog box displays.
2. Click the Informs tab.
3. Select the Enable informs option.
4. Select the fabric on which you want to enable Informs from the Fabric list.
NOTE
If you want to enable Informs only on specific switches in a Fabric, you must configure Informs
using the Element Manager on each switch or through the command line interface.
All Informs-capable switches display in the SNMP Informs Capable Switch in the Fabric table.
5. Click OK on the SNMP Setup dialog box.
SNMP Informs will be enabled on all switches in the SNMP Informs Capable Switch in the
Fabric table.
Disabling SNMP informs
To disable Informs, complete the following steps.
1. Select Monitor > SNMP Setup.
The SNMP Setup dialog box displays.
2. Click the Informs tab.
3. Select the Disable informs option.
4. Select the fabric on which you want to disable Informs from the Fabric list.
All Informs-capable switches display in the SNMP Informs Capable Switch in the Fabric table.
5. Click OK on the SNMP Setup dialog box.
SNMP Informs will be disabled on all switches in the SNMP Informs Capable Switch in the
Fabric table.
Summary of Contents for Brocade BladeSystem 4/12
Page 1: ...53 1001773 01 14 April 2010 DCFM Professional User Manual Supporting DCFM 10 4 X ...
Page 3: ...DCFM Professional User Manual iii 53 1001773 01 ...
Page 4: ...iv DCFM Professional User Manual 53 1001773 01 ...
Page 88: ...56 DCFM Professional User Manual 53 1001773 01 Seed switch 2 ...
Page 146: ...114 DCFM Professional User Manual 53 1001773 01 Customizing the main window 4 ...
Page 152: ...120 DCFM Professional User Manual 53 1001773 01 Launching HCM Agent 5 ...
Page 246: ...214 DCFM Professional User Manual 53 1001773 01 Syslog forwarding 8 ...
Page 262: ...230 DCFM Professional User Manual 53 1001773 01 Generating zoning reports 10 ...
Page 662: ...630 DCFM Professional User Manual 53 1001773 01 ...