6. Command Reference
458
Status
-
Status of the path
Online
: Online
Offline(C)
: Offline status caused by a command operation
Offline(E)
: Offline due to an error
Online(E)
: Failure has occurred (If none of the paths accessing
one Dev have an
Online
status, one of those paths is changed to
the
Online(E)
status.)
Paths that are
Offline(E)
or
Online(E)
require corrective
action. The appropriate action can be determined by referring to
5.3 What To Do for a Path Error
.
Type
#1
-
Attribute of the path
Own
: Owner path
Non
: Non-owner path
When connecting to Lightning 9900 series, Lightning 9900V
series, Hitachi USP, Universal Storage Platform V/VM, Virtual
Storage Platform, Hitachi AMS2000 series, or Hitachi SMS, all
paths are owner paths.
IO-Count
#1
-
Total I/O count for a path. The maximum value that can be
displayed is 2
32
- 1 (4294967295). If the total I/O count reaches the
maximum value, it is reset, and the count is re-started from 0.
To reset the
IO-Count
value to 0, execute the
dlnkmgr
command's
clear
operation. Executing the
clear
operation also
resets the number of I/O errors (
IO-Errors
) to 0. For details about
the
clear
operation, see
6.2 clear (Returns the Path Statistics to
the Initial Value)
.
IO-Errors
#1
-
Total I/O error count for a path. The maximum value that can be
displayed is 2
32
- 1 (4294967295). If the total I/O error count
reaches the maximum value, it is reset, and the count is re-started
from 0.
To reset the
IO-Errors
value to 0, execute the
dlnkmgr
command's
clear
operation. Executing the
clear
operation also
clears the number of I/O operations (
IO-Count
) to 0.
For details about the
clear
operation, see
6.2 clear (Returns the
Path Statistics to the Initial Value)
.
DNum
#1
-
Dev number, where 0 (fixed) is displayed.
This item pertains to a partition number.
Displayed item
Description
No summary
displayed
Summary
displayed
Summary of Contents for Dynamic Link Manager
Page 1: ...Hitachi Dynamic Link Manager Software User s Guide for Linux R 3000 3 F04 60 E ...
Page 4: ......
Page 16: ......
Page 154: ...3 Creating an HDLM Environment 130 Figure 3 1 Flow of HDLM Environment Setup ...
Page 162: ...3 Creating an HDLM Environment 138 ...
Page 309: ...3 Creating an HDLM Environment 285 Figure 3 33 Example of Creating an ext2 File System ...
Page 352: ......
Page 362: ...4 HDLM Operation 338 A Fibre Channel switch s zone setting is changed ...
Page 375: ...4 HDLM Operation 351 ...
Page 410: ......
Page 546: ......
Page 549: ...8 Messages 525 HDLM driver filter component HDLM alert driver HDLM management target ...
Page 590: ...8 Messages 566 dd dd Maintenance information hexadecimal number Action None ...
Page 594: ...8 Messages 570 aa aa Name of file where error was detected Action Reinstall an HDLM ...
Page 713: ...8 Messages 689 utility see 7 2 DLMgetras Utility for Collecting HDLM Error Information ...
Page 714: ......