4. HDLM Operation
379
4.
Refer to
/var/opt/DynamicLinkManager/log/dlmcfgmgr1.log
or
execute the
dlmcfgmgr
utility (
dlmcfgmgr -v
) or the view operation
(
dlnkmgr view -path
) of the HDLM command to make sure that the relevant
device is now managed by HDLM.
The following is an example of executing the
dlmcfgmgr
utility:
# /sbin/dlmcfgmgr -v
(8) Restoring the Path of an HDLM Device Started in Disconnected Status (When
a Restart Is Required)
This subsection describes how to restore the path to an HDLM device that was in
disconnected status (the cable was pulled out or broken) when the host first started. In
this method, the host is restarted. Note that this operation is applicable to an HDLM
device managed by HDLM only. Also note that the target path of restoration can be a
single, multiple, or all paths to the relevant HDLM device.
To restore the path of an HDLM device started in disconnected status (this procedure
restarts the host):
1.
Execute the HDLM-configuration definition utility (
dlmcfgmgr -v
) or the
view
operation (
dlnkmgr view -drv
) of the
dlnkmgr
command to check if the host
was started while the path to the relevant HDLM device was in disconnected
status.
The following are examples of executing the command or utility:
When executing the
dlmcfgmgr
utility with the
-v
option:
# /sbin/dlmcfgmgr -v
When executing the
view
operation with the
-drv
option:
# /opt/DynamicLinkManager/bin/dlnkmgr view -drv
If the SCSI device name mapped with the path to the relevant HDLM device is
represented with a hyphen (-) in the execution result, this means that the path was
in disconnected status.
Perform this operation if necessary. If it is not necessary to check this, go to step 2.
2.
Connect the cable.
If the cable is broken, replace it.
3.
Restart the host on which the HDLM is installed.
The SCSI device is recreated, the path to the HDLM device, which was
determined in step 1 to be in disconnected status when the host was started, is
restored automatically, and the status changes to online.
4.
Refer to
/var/opt/DynamicLinkManager/log/dlmcfgmgr1.log
or
execute the
dlmcfgmgr
utility (
dlmcfgmgr -v
) to check if the path to the
Summary of Contents for Dynamic Link Manager
Page 1: ...Hitachi Dynamic Link Manager Software User s Guide for Linux R 3000 3 F04 60 E ...
Page 4: ......
Page 16: ......
Page 154: ...3 Creating an HDLM Environment 130 Figure 3 1 Flow of HDLM Environment Setup ...
Page 162: ...3 Creating an HDLM Environment 138 ...
Page 309: ...3 Creating an HDLM Environment 285 Figure 3 33 Example of Creating an ext2 File System ...
Page 352: ......
Page 362: ...4 HDLM Operation 338 A Fibre Channel switch s zone setting is changed ...
Page 375: ...4 HDLM Operation 351 ...
Page 410: ......
Page 546: ......
Page 549: ...8 Messages 525 HDLM driver filter component HDLM alert driver HDLM management target ...
Page 590: ...8 Messages 566 dd dd Maintenance information hexadecimal number Action None ...
Page 594: ...8 Messages 570 aa aa Name of file where error was detected Action Reinstall an HDLM ...
Page 713: ...8 Messages 689 utility see 7 2 DLMgetras Utility for Collecting HDLM Error Information ...
Page 714: ......
Page 738: ......