3. Creating an HDLM Environment
277
# /opt/DynamicLinkManager/bin/dlnkmgr set -elfs 1000
Specify the size of the error log file in KB.
(8) Setting the Number of Error Log Files
The number of the error log files (the HDLM manager log (
dlmmgr
n
.log
(
n
indicates
a file number from
1
to
16
))) can be set.
You can specify a value from 2 to 16 for the number of HDLM manager log files.
By specifying both the log file size and the number of log files, you can collect up to
32000000KB (approximately 30GB) of error logs.
The following is an example of using a command to set the number of error log files.
# /opt/DynamicLinkManager/bin/dlnkmgr set -elfn 5
Specify the number of error log files by a number.
(9) Setting the Trace File Size
Trace files for which a trace file size can be set are
hdlmtr
n
.log
(
n
indicates a file
number from
1
to
64
). The length of a trace file is fixed, regardless of how much trace
information is actually in the file.
For the trace file size, you can specify a value (in kilobytes) from 100 to 16000. If you
specify a value smaller than the setting value, the KAPL01097-W message will be
displayed to confirm the execution, and the trace file will be temporarily deleted.
When all the trace files become full, the oldest file is overwritten with any new trace
data.
By specifying both the trace file size and the number of trace files, you can collect up
to 1024000 KB of trace data.
The following is an example of using a command to set the trace file size:
# /opt/DynamicLinkManager/bin/dlnkmgr set -systfs 2000
Specify the size of the trace file in KB.
(10) Setting the Number of Trace Files
Trace files for which the number of files can be set are
hdlmtr
n
.log
(
n
indicates a
file number from
1
to
64
).
For the number of trace files, you can specify a value from 2 to 64. If you specify a
value smaller than the value that has already been specified, the KAPL01097-W
Summary of Contents for Dynamic Link Manager
Page 1: ...Hitachi Dynamic Link Manager Software User s Guide for Linux R 3000 3 F04 60 E ...
Page 4: ......
Page 16: ......
Page 154: ...3 Creating an HDLM Environment 130 Figure 3 1 Flow of HDLM Environment Setup ...
Page 162: ...3 Creating an HDLM Environment 138 ...
Page 309: ...3 Creating an HDLM Environment 285 Figure 3 33 Example of Creating an ext2 File System ...
Page 352: ......
Page 362: ...4 HDLM Operation 338 A Fibre Channel switch s zone setting is changed ...
Page 375: ...4 HDLM Operation 351 ...
Page 410: ......
Page 546: ......
Page 549: ...8 Messages 525 HDLM driver filter component HDLM alert driver HDLM management target ...
Page 590: ...8 Messages 566 dd dd Maintenance information hexadecimal number Action None ...
Page 594: ...8 Messages 570 aa aa Name of file where error was detected Action Reinstall an HDLM ...
Page 713: ...8 Messages 689 utility see 7 2 DLMgetras Utility for Collecting HDLM Error Information ...
Page 714: ......
Page 738: ......