3. Creating an HDLM Environment
264
Table 3-55:
Formula for Calculating MISSCOUNT
•
When using Oracle RAC 10g 10.2.0.2.0 or later or Oracle RAC 11g:
In addition to the value of
MISSCOUNT
shown above, also change the value
of
DISKTIMEOUT
. As with
MISSCOUNT
, the value to be specified in
DISKTIMEOUT
is determined by the type of storage system. To make the
change, use the following table to obtain the value to be specified, and then
change the current value to a value equal to or greater than the value you have
obtained.
Table 3-56:
Formula for Calculating DISKTIMEOUT
For details on how to change
MISSCOUNT
and
DISKTIMEOUT
, contact the
company with which you have a contract for Oracle Support Services.
Note that when you uninstall HDLM from the above configuration, you must
reset the values of
MISSCOUNT
and
DISKTIMEOUT
to their original values.
Therefore, make a note of the original values of
MISSCOUNT
and
DISKTIMEOUT
before changing them.
Storage system type
Formula for obtaining the value of MISSCOUNT
•
Lightning 9900 series
•
Lightning 9900V series
•
Hitachi USP
•
Universal Storage Platform V/VM
•
Virtual Storage Platform
number-of-paths-connected-to-the-voting-disk
x
60 seconds
•
Hitachi AMS2000/AMS/WMS/SMS
series
•
Thunder 9500V series
number-of-paths-connected-to-the-voting-disk
x
30 seconds
Storage system type
Number of
paths
connected
to the
voting disk
Formula for obtaining the value of
DISKTIMEOUT
•
Lightning 9900 series
•
Lightning 9900V series
•
Hitachi USP
•
Universal Storage Platform V/VM
•
Virtual Storage Platform
3 or less
You do not need to change the value of
DISKTIMEOUT
.
4 or more
number-of-paths-connected-to-the-voting-disk
x
60 seconds
•
Hitachi AMS2000/AMS/WMS/SMS
series
•
Thunder 9500V series
6 or less
You do not need to change the value of
DISKTIMEOUT
.
7 or more
number-of-paths-connected-to-the-voting-disk
x
30 seconds
Summary of Contents for Dynamic Link Manager
Page 1: ...Hitachi Dynamic Link Manager Software User s Guide for Linux R 3000 3 F04 60 E ...
Page 4: ......
Page 16: ......
Page 154: ...3 Creating an HDLM Environment 130 Figure 3 1 Flow of HDLM Environment Setup ...
Page 162: ...3 Creating an HDLM Environment 138 ...
Page 309: ...3 Creating an HDLM Environment 285 Figure 3 33 Example of Creating an ext2 File System ...
Page 352: ......
Page 362: ...4 HDLM Operation 338 A Fibre Channel switch s zone setting is changed ...
Page 375: ...4 HDLM Operation 351 ...
Page 410: ......
Page 546: ......
Page 549: ...8 Messages 525 HDLM driver filter component HDLM alert driver HDLM management target ...
Page 590: ...8 Messages 566 dd dd Maintenance information hexadecimal number Action None ...
Page 594: ...8 Messages 570 aa aa Name of file where error was detected Action Reinstall an HDLM ...
Page 713: ...8 Messages 689 utility see 7 2 DLMgetras Utility for Collecting HDLM Error Information ...
Page 714: ......
Page 738: ......