5.7 Initializing (Reset)
76
Default Settings
Display
Setting value
Default value
Settings
MENU
TRG
INT/ EXT/ MANU
EXT
Trigger setting function
(p. 31)
RANGE
↑
/
↓
[When low-power resistance mea-
surement is set to OFF]
100 m
Ω
/ 1000 m
Ω
/ 3
Ω
/
10
Ω
/ 100
Ω
/ 300
Ω
/ 1000
Ω
/ 10 k
Ω
/
30 k
Ω
/ 100 k
Ω
/
300 k
Ω
/ 1000 k
Ω
/ 3 M
Ω
/
10 M
Ω
/ 30 M
Ω
/ 100 M
Ω
(default)
[When low-power resistance mea-
surement is set to ON]
1000 m
Ω
/ 3
Ω
/ 10
Ω
/ 100
Ω
/ 300
Ω
/
1000
Ω
100 M
Ω
Range switching function
(p. 32)
SPEED
SLOW/ MED/ FAST
FAST
Measurement speed (p. 29)
0ADJ
OFF/ ON
OFF
Zero adjustment function (p. 34)
COMP
OFF/ ON
ON
Comparator function (p. 36)
LOCK
OFF/ FULL / MENU
OFF
MISC
MEAS/ DATA/ SYSTEM
(Miscellaneous settings)
MISC
MEAS
DELAY1
0 to 100 ms (all ranges)
0 ms
Probe delay setting (p. 44)
DELAY2
0 to 100 ms
0 ms
DUT response setting (p. 44)
SCALING
OFF/ON
Coefficient A
Offset B
OFF
A:1
B:0
Scaling function (p. 46)
INT (FAST)
0.1 ms to 100 ms
1PLC to 6PLC (60 Hz)
1PLC to 5PLC (50 Hz)
Depends on measure-
ment range
INT (MED)
INT (SLOW)
CONT CHECK
OFF/ ON
ON, 200
Ω
Contact check (p. 50)
50
Ω
/ 100
Ω
/ 150
Ω
/ 200
Ω
/ 300
Ω
/
400
Ω
/ 500
Ω
CONT IMP
OFF/ ON/ PULSE
17 mA/ 25 mA/ 35 mA/ 50 mA
ON, 35 mA (ranges from
100 m
Ω
to 100 k
Ω
)
PULSE, 35 mA (ranges
from 300 k
Ω
to 100 M
Ω
)
VOLT MONITOR
OFF/ ON/ ALLOFF
ON, NORMAL (LOOSE
when 100 M
Ω
range)
Voltage Monitor Function (p. 55)
LOOSE/ NORMAL/ SEVERE
CURRENT MODE
CONT/ PULSE
PULSE
Current mode setting function (p. 56)
DATA
AUTO MEMORY
OFF/ ON
OFF
Auto-Memory function (p. 81)
STATISTICS
OFF/ ON
OFF
Statistical calculation function (p. 84)
DATA OUT
OFF/ ON
OFF
Data output function (p. 87)
Summary of Contents for RM3542-50
Page 1: ......
Page 2: ......
Page 6: ...Table of Contents iv...
Page 26: ...1 3 Screen Organization 20...
Page 32: ...2 3 Turning the Power On and Off 26...
Page 48: ...3 8 Confirming Faulty Measurements 42...
Page 72: ...4 14 Compensating for Thermal EMF Offset Offset Voltage Compensation OVC 66...
Page 84: ...5 7 Initializing Reset 78...
Page 94: ...6 4 Auto Exporting Measurement Values at End of Measurement Data Output Function 88...
Page 206: ...11 4 Disposing of the Instrument 200...
Page 216: ...Appendix 5 Dimensional diagram A10 Appendix 5 Dimensional diagram Unit mm...
Page 230: ...Index Index 4...
Page 231: ...HIOKI E E CORPORATION...
Page 232: ......
Page 233: ......
Page 234: ......