![Hioki RM3542-50 Instruction Manual Download Page 185](http://html1.mh-extra.com/html/hioki/rm3542-50/rm3542-50_instruction-manual_2137361185.webp)
9.10 Device Compliance Documents
179
9
"Information on compliance to standards" based on the IEEE488.2 standard
9.10 Device Compliance Documents
Item
Description
1. IEEE 488.1 interface functions
See:
"GP-IB Specifications (Interface Functions) (RM3542-
51 only)" (p. 110)
2. Operation with a device address other than 0
through 30
A setting outside the 0 to 30 range cannot be performed.
3. Timing of changed device address recognition
A change of address is recognized immediately after changing.
4. Device settings at power on
Status information is cleared. Others will be backed up. How-
ever, the header on/off setting, response message separator
and terminator are all reinitialized.
5. List of message exchange options
•
Input buffer capacity and operation
See:
Queries to which multiple response message units are re-
turned.
:CALCulate:STATistics:NUMBer?
.................2
:CALCulate:STATistics:MAXimum?
..............2
:CALCulate:STATistics:MINimum?
..............2
:CALCulate:STATistics:LIMit?
....................4
:CALCulate:STATistics:DEViation?
.........2
:CALCulate:STATistics:CP?
............................2
:MEMory:DATA?
..................... Number of stored values
:CALCulate:LIMit:ABS?
......................................2
:CALCulate:LIMit:PERCent?
............................2
:SYSTem:DATE?
...........................................................3
:SYSTem:TIME?
...........................................................3
•
Queries producing responses when syntax is checked:
All queries produce responses when syntax checking is
performed.
•
Whether any queries produce responses when read:
There are no queries which produce response messages at
the instant they are read in by the controller.
•
Whether any commands are coupled:
There are no relevant commands.
6. Summary of functional elements for use when
constructing device specific commands, and
whether compound commands or program
headers can be used:
The followings can be used.
•
Program message
•
Program message terminator
•
Program message unit
•
Program message unit separator
•
Command message unit
•
Query message unit
•
Command Program Headers
•
Query Program Header
•
Program data
•
Character program data
•
Decimal program data
•
Compound commands and program headers
7. Buffer capacity limitations for block data
Block data is not used.
Summary of Contents for RM3542-50
Page 1: ......
Page 2: ......
Page 6: ...Table of Contents iv...
Page 26: ...1 3 Screen Organization 20...
Page 32: ...2 3 Turning the Power On and Off 26...
Page 48: ...3 8 Confirming Faulty Measurements 42...
Page 72: ...4 14 Compensating for Thermal EMF Offset Offset Voltage Compensation OVC 66...
Page 84: ...5 7 Initializing Reset 78...
Page 94: ...6 4 Auto Exporting Measurement Values at End of Measurement Data Output Function 88...
Page 206: ...11 4 Disposing of the Instrument 200...
Page 216: ...Appendix 5 Dimensional diagram A10 Appendix 5 Dimensional diagram Unit mm...
Page 230: ...Index Index 4...
Page 231: ...HIOKI E E CORPORATION...
Page 232: ......
Page 233: ......
Page 234: ......