background image

www.grassvalley.com

UCP

-

3901

Unified Compute Processor for Densité

IQUCP25 / IQUCP50

Unified Compute Processor for IQ Modular

User Manual

13-03084-010-M00 AD

2022-02-23

Summary of Contents for IQUCP25

Page 1: ...www grassvalley com UCP 3901 Unified Compute Processor for Densité IQUCP25 IQUCP50 Unified Compute Processor for IQ Modular User Manual 13 03084 010 M00 AD 2022 02 23 ...

Page 2: ...hout notice Terms and Conditions Please read the following terms and conditions carefully By using UCP 3901 documentation you agree to the following terms and conditions Grass Valley hereby grants permission and license to owners of UCP 3901 to use their product manuals for their own internal business use Manuals for Grass Valley products may not be reproduced or transmitted in any form or by any ...

Page 3: ...t se produire lorsque des composants électroniques ne sont pas manipulés de manière adéquate ce qui peut entraîner des défaillances intermittentes ou endommager irrémédiablement un circuit électrique Au moment de remplacer une carte dans un châssis prenez toujours les mesures de protection antistatique appropriées Assurez vous que le châssis est relié électriquement à la terre par le cordon d alim...

Page 4: ...tal Information European CE WEEE directive This symbol on the product s means that at the end of life disposal it should not be mixed with general waste Visit www grassvalley com for recycling information Grass Valley believes this environmental information to be correct but cannot guarantee its completeness or accuracy since it is based on data received from sources outside our company All specif...

Page 5: ...ct exposure to the laser beam Even though the power of these lasers is low the beam should be treated with caution and common sense because it is intense and concentrated Laser radiation can cause irreversible and permanent damage of eyesight Please read the following guidelines carefully Make sure that a fiber is connected to the board s fiber outputs before power is applied If a fiber cable e g ...

Page 6: ...d Connectors Grass Valley products are designed to meet or exceed the requirements of the appropriate European EMC standards In order to achieve this performance in real installations it is essential to use cables and connectors with good EMC characteristics WARNING This equipment is compliant with Class A of CISPR 32 In a residential environment this equipment may cause radio interference Note Th...

Page 7: ...ll SIGNAL DATA PORTS For unconnected signal data ports on the unit fit shielding covers For example fit EMI blanking covers to SFP type ports and fit 75 Ω RF terminators to HD BNC type ports COAXIAL CABLES Coaxial cables connections particularly serial digital video connections shall be made with high quality double screened coaxial cables such as Belden 8281 or BBC type PSF1 2M Belden 1694A for 3...

Page 8: ...8 Notices ...

Page 9: ...e Upgrade Licenses for IQUCP25 IQUCP50 25 Supported SFP28 Cartridges for IQUCP25 IQUCP50 26 Supported Multiviewer Media Network Input Capacity 26 2 UCP 3901 Card Installation and Operation 27 Front Card edge Interface 27 SFP Socket Status Indicators 30 Fiber Optic Handling 30 Installation 31 Getting Organized Unpacking 31 Required Tools 31 Required Material 31 Installation of the Rear Connector Pa...

Page 10: ...Multiviewer SDC Mosaic Output to a 4K Display Input Cable Connection 57 About HDMI Type Signal Connections 57 5 Connecting to the Card s Configuration Interface 59 Installing RollCall 59 IP Address and Network Port Usage 59 Connecting to the UCP 3901 IQUCP25 IQUCP50 Card with RollCall 60 First Time Connection to the UCP 3901 IQUCP25 IQUCP50 Card with RollCall60 Connecting to the Multiviewer SDC wi...

Page 11: ...RTP Receiver 105 Ethernet RTP Receiver Video Stats 107 Ethernet RTP Receiver Audio Stats 108 Ethernet RTP Receiver Meta Stats 109 Link Control 110 Configuring the Streams for use with 4K UHD Two Sample Interleave Division111 Configuring the Streams for use with 4K UHD SQDS 112 HDR Receiver Control 114 Destination Timing 116 Frame Sync 117 Audio V Fade 119 Input Loss Control 120 Spigot Pages 121 In...

Page 12: ...180 Histogram Panel 182 Visible Clocks Panel 183 Counters 184 FEC 185 NMOS 187 Label Patterns 189 Defining a Label Pattern 189 Ethernet Pages 1 and 2 192 Ethernet 1 and 2 RTP Sender 195 Ethernet 1 and 2 RTP Receiver 196 Ethernet RTP Receiver Audio Stats 198 Audio V Fade 199 Spigot Pages 200 MADI Signal Conversion Direction by Spigot Number 200 Pairing Inputs and Outputs for Redundancy 200 Input Sp...

Page 13: ...er SDC Video Wall 253 STEP 1 Preliminary Multiviewer SDC Configuration 253 STEP 1 1 Preliminaries UCP 3901 Templates 253 STEP 1 2 Preliminaries Multiviewer SDC Templates 254 STEP 2 UCP 3901 Media Interface s Setup Video IP Streams 255 Manual Configuration of the Media Interfaces 256 STEP 3 Make a Change to the Video Wall 257 Introduction 257 Assumptions 257 Get Orbit Multiviewer Project from the M...

Page 14: ...der 289 Ethernet 1 and 2 RTP Receiver 289 Ethernet RTP Receiver Video Stats 289 Ethernet RTP Receiver Audio Stats 289 Ethernet RTP Receiver Meta Stats 289 Link Control 290 Destination Timing 291 Audio V Fade 291 Input Loss Control 292 Spigot Pages 292 Spigot 1 to 4 Multiviewer Head Outputs 292 Spigot 5 to 16 Multiviewer Inputs 292 Logging Configuration 293 Logging SDI Info 293 Logging System 293 L...

Page 15: ...nits 319 Replacing Cards 319 Replacing a rear panel 320 Removing a card 320 Installing a Card 320 Cooling Fan Operational Assessment 320 Diagnostics 320 Critical Temperature Alarm Corrective Actions 321 Fan Noise 321 Fan Alarm and Fan Noise Corrective Actions 321 Replacing the UCP 3901 s Fan 322 Fan Replacement Kit 322 Required Tools 322 Cooling Fan Replacement Procedure 322 To remove a fan 323 To...

Page 16: ...1 Essence Processing EP Ethernet Media Ports SFP1 SFP2 332 MADI Gateway MD Ethernet Media Ports SFP1 SFP2 333 Multiviewer MV Ethernet Media Ports SFP1 SFP2 333 RollCall Features 334 Communication 334 Status LEDs 334 Power Consumption 334 Appendix A Installing the SFP Ethernet Module 335 Introduction 335 Installing an SFP module 335 Connecting the fiber optic cables 336 Removing the fiber optic cab...

Page 17: ...eway MD SDC on 10G 25G networks only NMOS IS 04 discovery and registration with group hint tag support NMOS IS 05 device connection management In band or out of band control of NMOS for a UCP 3901 In band control of NMOS for a IQUCP25 IQUCP50 Essence Processing EP SDC For SDI to IP gateway type applications See Essence Processing SDC on page 71 for information on how to configure this option SDI I...

Page 18: ...viewer head display outputs Multiviewer video wall layouts are designed using the Grass Valley Orbit software tool The multiviewer SDC requires the multiviewer license Flexible configurations 12 x 1 UHD quad link or 12 x 4 3G IP inputs IP outputs and SDI HD BNC copy outputs Audio metering support UMD and Tally support Clocks and Timers See Multiviewer SDC on page 277 for information on how to conf...

Page 19: ...01 25 EP Universal Compute Processor Functional Block Diagram Document Number Software Defined Core Title Multiviewer Essence Processing MADI Gateway 3084 2927 001 AA UCP 3901 IQUCP25 IQUCP50 User Manual this document 3084 2928 001 AA UCP 3901 IQUCP25 IQUCP50 Release Notes RollCall V4 Suite RollCall Lite Installation Guide RollCall Control Panel User Manual RollMechanic Operator s Manual 13 03082 ...

Page 20: ...erence Rx Tx SFP 1 25 10GbE Rx Tx SFP 2 25 10GbE Rx Tx SFP 1 25 10GbE Rx Tx SFP 2 25 10GbE NMOS IS 04 IS 05 ST 2059 ST 2110 30 ST 2110 30 ST 2110 30 ST 2110 30 IP Decap With 7 Dual Rx Hitless Reference Audio Channel Config ST 2110 30 ST 2110 30 ST 2110 30 ST 2110 30 IP Encap With 7 Dual TX MADI 9 11 13 15 Management 8 MADI to IP Channels 8 IP to MADI Channels MADI TDM MUX MADI 10 12 14 16 MADI TDM...

Page 21: ...C for Densité See Rear Panel and Connectors on page 32 Software Upgrade Selection For use with card Description UCP 3901 25G EP UCP 3901 Essence processing license for SDI to from IP with synchronization For use up to 25G option 2 x 25G SFP UCP 3901 50G EP UCP 3901 Essence processing license for SDI to from IP with synchronization For use up to 50G option 4 x 25G SFP UCP 3901 25G MD UCP 3901 MADI ...

Page 22: ...2 MMF 33m link with OM1 MMF 850 nm multi mode optical transceiver that supports signals up to 10 5 Gb s for bidirectional serial data communications such as 10GBASE SR and 10GBASE SW SFP ETH10G RT S13 LC Long range optical 10GBase Ethernet SFP cartridge with LC PC fiber connector 10 000m 1310 nm single mode optical transceiver that supports signals up to 10 5 Gb s for bidirectional serial data com...

Page 23: ...f 12G to IP and two blocks of IP to 12G or there may be as many blocks needed for your HD 3G configurations These will include quad stream to single 12G SDI or 2SI quad link to single stream UHD Single stream UHD only supported in SMPTE ST 2110 0 to 16 SDI to IP Channels 0 to 16 IP to SDI Channels Network Intelligence Control Monitoring IQUCP5000 EP Essence Processing Block Diagram PTP Bi Tri Leve...

Page 24: ...l TX Depending on the FPGA configuration loaded there may be four blocks of 12G to IP or four blocks of IP to 12G or there may be as many blocks needed for your HD 3G configurations These will include quad stream to single 12G SDI or 2SI quad link to single stream UHD Single stream UHD only supported in SMPTE ST 2110 0 to 16 SDI to IP Channels 0 to 16 IP to SDI Channels Network Intelligence Contro...

Page 25: ... x 25 GbE I O on SFP connectors Includes IQFAN rear panel for additional cooling required if using with IQH3B enclosures IQUCP5000 2B3 16 x 3G SDI I O 4 of which support 12G SDI 2 x 50 GbE I O on a single 100 GbE QSFP connector Suitable for use with IQH4B enclosures IQUCP5001 3B3 16 x 3G SDI I O 4 of which support 12G SDI 2 x 50 GbE I O on a single 100 GbE QSFP connector Includes IQFAN rear panel ...

Page 26: ...LR 10GBASE LR long range SFP for SMF single mode fiber supported for IQUCP MD essence only FCS 25GE SR 25GBASE SR short range SFP for MMF multi mode fiber FCS 25GE LR 25GBASE LR long range SFP for SMF single mode fiber CABQ4S100G2M Copper Breakout Cable 2M 100GbE QSFP to 4x25GbE CABQ4S100G3M Copper Breakout Cable 3M 100GbE QSFP to 4x25GbE CABQ4S100G5M Copper Breakout Cable 5M 100GbE QSFP to 4x25Gb...

Page 27: ... SELECT button is pressed These multi color LEDs indicate the status of the UCP 3901 Card by color and by flashing steady illumination Ejector Tab SELECT Button USB unused Densité LED UCP 3901 Card Right Side UCP 3901 Card Left Side DIAG SDI IN 9 SDI IN 1 SDI IN 10 SDI IN 2 SDI IN 11 SDI IN 3 SDI IN 12 SDI IN 4 BOARD SDI IN 13 SDI IN 5 PTP SDI IN 14 SDI IN 6 CPU SDI IN 15 SDI IN 7 REF SDI IN 16 SD...

Page 28: ...port status Green Valid flow is detected Yellow Test pattern generator has been activated Red Flow is not found or invalid Off Output Spigot not in use See also Spigot Pages on page 121 and Logging SDI Info on page 138 for more information For UHD Quad Link Modes Banks of four adjacent LEDs for example 1 4 5 8 and so on will light simultaneously to denote the 4 x 3G streams being received on a 12G...

Page 29: ...roperly inserted See Replacing the Micro SD Card on page 324 Yellow level 2 Card is booting Green level 1 Card has finished booting Normal operation Flashing Yellow level 5 Card has been selected for local control using the Densité frame s control panel by having pressed the card s SELECT button Press the card s SELECT button again to remove local control Alternating Red Green level 4 Card s firmw...

Page 30: ...ith side shields See also Keep Fiber Connections Clean on page 327 SELECT Button Press to select this card for local control using the Densité frame s control panel Through the Densité frame s control panel you can set the card s IP addresses of the Ethernet interfaces See Local control using the Densité frame control panel to set the Card s IP Addresses on page 38 USB Socket Unused Reset Button P...

Page 31: ...ector Panel and Card Grass Valley Densité series cards are each associated with a rear connector panel which must be installed in the Densité frame before the card can be inserted The UCP 3901 card is designed to fit into Grass Valley s Densité 3 or Densité 3 frame See UCP 3901 Ordering Information on page 21 for details about the cards and rear panels that are available See Rear Panel and Connect...

Page 32: ...g rear connector panel has been installed install the UCP 3901 card as follows 1 Open the front panel of the frame 2 Slide the UCP 3901 card into the slot and push gently on the handle to seat the connectors When using a double slot width rear panel the card should be inserted into the right most of the two slots Inserting the card into the wrong slot will not damage the card and will be flagged b...

Page 33: ...ect See Understanding IQUCP25 IQUCP50 Configuration Use Cases on page 78 and Technical Specifications on page 329 Connector Nomenclature Count UCP 3901 3 DRP Rear Connector Type Used for SDC application 12G 3G HD SD SDI I O 4 HD BNC Essence Processing MADI Gateway 3G HD SD SDI I O 12 HD BNC Essence Processing MADI Gateway Multiviewer head display outputs 1 to 4 on HD BNCs 13 14 15 and 16 only ...

Page 34: ...sing EP Connect a serial digital video signal to the HD BNC labeled 12G 3G HD SD SDI I O 1 to 12G 3G HD SD SDI I O 4 conforming to the SMPTE 2082 10 standard for a 12 G input signal SMPTE 425 1 standard for a 3G input signal SMPTE 292 1 standard for an HD input signal For EP SDC v17 2 only SMPTE 425 5 standard for link 1 to 4 of a quadlink3GHDsignalsto transmita4KUHDsignal Foraquadlink configurati...

Page 35: ...mita4KUHDsignal Foraquadlink configuration see Link Control on page 110 For outputs see the spigot configuration MADI Gateway MD Connect a serial digital signal to the HD BNC Inputs labeled 3G HD SD SDI I O 5 to 3G HD SD SDI I O 8 conforming to AES10 2008 Obtain a serial digital signal from the HD BNC Outputs labeled 3G HD SD SDI I O 9 to 3G HD SD SDI I O 16 conforming to AES10 2008 Inputs and out...

Page 36: ...ard To support the following protocols PTP NMOS IS 04 and IS 05 These fiber optic interfaces consists of two parts A socket on the rear panel into which an optional SFP interface module is plugged 3G HD SD SDI I O 8 8 3G HD SD SDI I O 8 MADI In 8 Not used 3G HD SD SDI I O 9 9 3G HD SD SDI I O 9 MADI Out 9 Not used 3G HD SD SDI I O 10 10 3G HD SD SDI I O 10 MADI Out 10 Not used 3G HD SD SDI I O 11 ...

Page 37: ...card s configuration SFP1 is identified as Ethernet 1 and SFP2 is identified as Ethernet 2 in the SFP Configuration page see SFP Configuration on page 170 See Installing the SFP Ethernet Module on page 335 for instructions on installing and removing the SFP interface module and for plugging and unplugging the LC terminated fibers See Supported SFP28 Cartridges for IQUCP25 IQUCP50 on page 26 for th...

Page 38: ...anel buttons to navigate through the menu The menu allows you to view and set the UPC 3901 card s current MANAGEMENT Ethernet port IP address that you use in RollCall to connect to the card See also Ethernet Gb on page 165 SFP1 and SFP2 Ethernet port IP addresses that you use for media streams See also Ethernet Pages 1 and 2 on page 101 The Ethernet port configuration parameters are The Ethernet p...

Page 39: ...alue is shown pushing this button once enables modification of the value using the and buttons a second push confirms the new value ESC Cancels the effect of parameter value changes that have not been confirmed pushing ESC causes the parameter to revert to its former value Pushing ESC moves you back up to the previous menu level At the main menu ESC does not exit the menu system To exit re push th...

Page 40: ...sing Grass Valley s RollCall This manual describes the control panels associated with the UCP 3901 and their use Please consult the RollCall User s Guide for information about setting up and operating RollCall In RollCall double click the UCP 3901 in the tree to open the configuration panel See Connecting to the Card s Configuration Interface on page 59 ...

Page 41: ...tion Front Card edge Interface The LEDs on the front edge of the module indicate its operating status Front Panel Front Edge STATUS IDENT button BOARD CPU PTP REF 8 16 7 15 6 14 5 13 4 12 3 11 2 10 1 9 SFP 2 QSFP 2 SFP 1 QSFP 1 RESET button ...

Page 42: ...LED Future use REF status LED Shows the following state Flashing Green Watchdog timer OK SDI IN 1 to SDI IN 16 status LEDs As an input this shows the following port status Green Signal is detected Yellow Test pattern generator has been activated Red Signal loss Off Input Spigot not in use As an output this shows the following port status Green Valid flow is detected Yellow Test pattern generator h...

Page 43: ...LED Status Indicator Red Fault 3V3 regulator failure Green 10G OK Blue 25G OK 50G Ethernet QSFP Socket Link LED Status Indicator Red Fault 3V3 regulator failure Blue 50G 100G OK SFP 1 to SFP 4 status LEDs Shows the SFP 1 2 3 and 4 link status Blue Link OK 25G 50G 100G SFP Blue flashing SFP detected link down fiber not connected different FEC selection from host Unlit SFP not detected See also Ethe...

Page 44: ...order SFP modules as per order Required Tools In addition to the above you will need the following tools field supplied Phillips 2 screwdriver to remove and install rear panels Required Material In addition to the above you will need the following field supplied Client PC Optionally for a multiviewer display cables converter to connect your multiviewer to displays At least one IQ B style frame wit...

Page 45: ... being changed remove it as described above 2 Remove the existing panel either blank or belonging to an existing card that is being changed by releasing the screw s 3 Position the new panel and secure it in place with the screw s Step 2 To install the IQUCP25 IQUCP50 Card Once a matching rear connector panel has been installed install the IQUCP card as follows 1 Open the front panel of the frame 2...

Page 46: ...l not damage the card and will be flagged by the on card status LED flashing red to indicate that there is no connection to the rear panel 3 Close the front panel of the frame Installation of the Optical Interface option See Installing the SFP Ethernet Module on page 335 Rear Panel and Connectors Images of Rear Panel Connectors The rear panel is shown below and its various inputs and outputs are d...

Page 47: ...47 UCP 3901 User Manual IQUCP2504 2B3 IQUCP2505 3B3 IQUCP5000 2B3 ...

Page 48: ...48 IQUCP Card Installation and Operation Rear Panel and Connectors IQUCP5001 3B3 IQUCP5002 2B3 IQUCP5003 3B3 ...

Page 49: ...rial inputs outputs 16 Connector Nomenclature Count Rear Connector Type Used for SDC application Serial inputs outputs 16 HD BNC Essence Processing MADI Gateway Multiviewer head display outputs 1 to 4 on HD BNCs 13 14 15 and 16 only SFP1 to SFP2 4 QSFP Essence Processing MADI Gateway Multiviewer SDC application Supported Signal Types Essence Processing EP Connect a serial digital video signal to t...

Page 50: ... Serial inputs outputs 2 2 12G 3G HD SD SDI I O 2 MADI In 2 Not used Serial inputs outputs 3 3 12G 3G HD SD SDI I O 3 MADI In 3 Not used Serial inputs outputs 4 4 12G 3G HD SD SDI I O 4 MADI In 4 Not used Serial inputs outputs 5 5 3G HD SD SDI I O 5 MADI In 5 Not used Serial inputs outputs 6 6 3G HD SD SDI I O 6 MADI In 6 Not used Serial inputs outputs 7 7 3G HD SD SDI I O 7 MADI In 7 Not used Ser...

Page 51: ...ation on page 170 See Installing the SFP Ethernet Module on page 335 for instructions on installing and removing the SFP interface module and for plugging and unplugging the LC terminated fibers See Supported SFP28 Cartridges for IQUCP25 IQUCP50 on page 26 for the SFP modules supported by the IQUCP25 IQUCP50 Control options The IQUCP25 IQUCP50 can be controlled in the following ways Grass Valley s...

Page 52: ...52 IQUCP Card Installation and Operation Remote control using RollCall ...

Page 53: ... UCP 3901 Multiviewer Network CablingFigure 4 1 on page 53 UCP 3901 EP SDC Multimode Fiber Cat5 Typical Stream Source PC with RollCall SFP1 Media Network Switch Management Network Switch MANAGEMENT NMOS Registry UCP 3901 MV SDC Multimode Fiber Cat5 Typical Stream Source PC with RollCall SFP1 Media Network Switch Management Network Switch MANAGEMENT Mosaic Outputs HD BNC SDI Optional NMOS Registry ...

Page 54: ...Essence Processing Network Cabling Fig 4 4 Typical IQUCP25 IQUCP50 Multiviewer Network CablingFigure 4 1 on page 53 IQUCP25 IQUCP50 EP SDC Multimode Fiber Cat5 Typical Stream Source PC with RollCall SFP1 Media Network Switch Management Network Switch NMOS Registry IQ Modular Chassis Ethernet Port IQ Modular Chassis IQ Modular Chassis Ethernet Port IQUCP25 IQUCP50 MV SDC Multimode Fiber Cat5 Typica...

Page 55: ...This process is seamless because switching between the streams is instantaneous and does not impact content PREREQUISITES At least two DCNM compliant switches must be used for this application Contact Grass Valley for more information about switch compatibility See Grass Valley Technical Support on page 106 For the UCP 3901 IQUCP25 IQUCP50 in both Rollcall s Input Spigot panel and Output Spigot pa...

Page 56: ...in greater detail below for IQUCP25 IQUCP50 Media Network Switch Red Multimode Fiber Cat5 PC with RollCall SFP2 SFP1 Media Network Switch Blue Management Network Switch MANAGEMENT NMOS Registry IQUCP25 IQUCP50 Media Network Switch Red Multimode Fiber Cat5 PC with RollCall SFP2 SFP1 Media Network Switch Blue Management Network Switch NMOS Registry IQ Modular Chassis Ethernet Port IQ Modular Chassis...

Page 57: ...ength is required Contact Technical Support to purchase long range active cables that have been tested to work with this multiviewer See Grass Valley Technical Support on page 338 About HDMI Type Signal Connections HDMI type multiviewer outputs are compatible with HDMI cables and display devices with HDMI compliant inputs The performance of HDMI cables has been standardized for each generation of ...

Page 58: ...58 Connections and Cabling About HDMI Type Signal Connections ...

Page 59: ...nect to it See Local control using the Densité frame control panel to set the Card s IP Addresses on page 38 Once you have connected to the card with RollCall you can change the card s IP configuration through RollCall see Ethernet Gb on page 165 and Ethernet Pages 1 and 2 on page 101 Certain ports must be open on the management IQ modular chassis network This information can be found under Port U...

Page 60: ...CP 3901 IQUCP25 IQUCP50 card is supplied with software which contains each of the available Software Defined Cores SDC unlicensed By default a new UCP 3901 IQUCP25 IQUCP50 card starts up with the Essence Processing core selected but it is unlicensed You must then license the SDCs you will use 1 For a UCP 3901 card only set the IP address for the MANAGEMENT Ethernet port See Local control using the...

Page 61: ...install the required licenses for the SDCs you will be using for your installation See Available Upgrade Licenses for IQUCP25 IQUCP50 on page 25 for a list of available licenses See Installing a License into a UCP 3901 IQUCP25 IQUCP50 on page 314 to install the license s 6 Configure the card according to the model and the software defined core Card model Software Defined Core Description Multiview...

Page 62: ...iguration parameter you can access both configuration components at the same IP address using a single network connection to the card You will still use two different port numbers to individually access the card s two configuration components See also Figure 4 2 on page 53 Proceed as follows 1 Set the UCP 3901 s IP address for the MANAGEMENT SFP1 and SFP2 Ethernet port IP addresses See Local contr...

Page 63: ...mple if the card s management IP address is 10 37 17 160 then connect to the Multiviewer SDC on port 2051 as follows 10 37 17 160 2051 4 Navigate to Multiviewer Configuration template page and set Multiviewer Control Interface to 1G ...

Page 64: ... UCP 3901 Card at the MANAGEMENT IP address at port 2050 default Configures items associated with the UCP 3901 Card through RollCall See RollCall Templates UCP 3901 Card Configuration on IP port 2050 on page 278 Multiviewer SDC Connect with RollCall to the Multiviewer SDC of the UCP 3901 Card at the MANAGEMENT IP address at port 2051 Interface used by Grass Valley Orbit Client tool to setup IP rou...

Page 65: ...ar chassis IP address at port 2050 default Multiviewer SDC at the SFP1 IP address at port 2051 PREREQUISITE The Multiviewer SDC license must have been installed 1 Connect to the IQUCP25 IQUCP50 card through it default port 2050 See First Time Connection to the UCP 3901 IQUCP25 IQUCP50 Card with RollCall on page 60 2 Navigate to the high speed Ethernet configuration pages for SFP1 and SFP2 See Ethe...

Page 66: ... example if the card s SFP1 IP address is 10 37 17 160 then connect to the Multiviewer SDC on port 2051 as follows 10 37 17 160 2051 6 Navigate to Multiviewer Configuration template page and set Multiviewer Control Interface to Ethernet 1 or Ethernet 2 according to the high speed media network your PC has network connectivity to ...

Page 67: ...port 2050 default Configures items associated with the UCP 3901 Card through RollCall See RollCall Templates UCP 3901 Card Configuration on IP port 2050 on page 278 Multiviewer SDC Connect with RollCall to the Multiviewer SDC of the IQUCP25 IQUCP50 card at the SFP1 or SFP2 IP address at port 2051 Interface used by Grass Valley Orbit Client tool to setup IP routing to from the module push pull mult...

Page 68: ...See Upgrading the UCP 3901 IQUCP25 IQUCP50 s SDC Application on page 309 Terminology Used with RollCall Term Description Essence A general term used to describe an SDI component video audio and data are all essences Spigot Generic term for a source or destination of a Video IP stream on an IP network Flow SMPTE ST 2022 2110 20 2110 30 and 2110 40 are all flow types An SDI input can be used to crea...

Page 69: ...he pages will also open a page view list allowing quick access to any of the pages Setting Values in RollCall Many of the settings within the templates have values either alpha or numeric When setting a value in a field the value whether text or a number must be set by pressing the Enter key or clicking the Save Value button Clicking an associated Preset Value button returns the value to the facto...

Page 70: ...70 Connecting to the Card s Configuration Interface Setting Values in RollCall ...

Page 71: ...cast allowing point to point operation or transmission in multicast groups and forward error correction Standards supported 3G SDI to SMPTE 424M 425M level A compatible HD SDI to SMPTE292M 274M 296M SD SDI to SMPTE259M C 25GbE Ethernet to IEEE 802 3 RollCall control and monitoring compatible with standard logging and reporting features Essence Processing Features Handles up to 16 SDI signals over ...

Page 72: ...net 1 and 2 RTP Receiver on page 105 Ethernet RTP Receiver Video Stats on page 107 Ethernet RTP Receiver Audio Stats on page 108 Ethernet RTP Receiver Meta Stats on page 109 Link Control on page 110 HDR Receiver Control on page 114 Destination Timing on page 116 Audio V Fade on page 119 Input Loss Control on page 120 Spigot Pages on page 121 Input Spigots on page 122 Output Spigots on page 127 Aud...

Page 73: ...73 UCP 3901 User Manual Setup on page 163 Ethernet Gb on page 165 Interop on page 168 SFP Configuration on page 170 ...

Page 74: ...he Video Selection and Information Select panes to the right of the Information display Figure 6 1 Information and Selection Panes Selecting the Information to Display Select the inputs to display data for from the Video Selection drop down list Select Video Input Status Video Output Status Network Status or Spigot Link Status from the Information Select pane as required The selected information t...

Page 75: ...sic card parameters to be set Figure 6 2 Configuration Page Note SDC functionality options are set here See also Upgrading the UCP 3901 IQUCP25 IQUCP50 s SDC Application on page 309 and Installing a License into a UCP 3901 IQUCP25 IQUCP50 on page 314 for more information ...

Page 76: ... confirm the change Interface Configuration Displays the IP address for each of the Ethernet interfaces Card Firmware Software Version Each software version contains multiple firmware images These allow different spigot input output and flow standard combinations to be selected Select the required software from the Software Version pane then select the firmware which provides the required combinat...

Page 77: ...that Restore and Restart buttons are displayed only when an item not currently installed is selected 2 Enable the Reset to Defaults on Restart checkbox This will cause existing details stored on the module other than network IP settings to be cleared down prior to restarting the module See Defaults on page 164 for more information 3 Click Restart to restart the module and implement any changes mad...

Page 78: ...ST2110 4 ST2022 This is an extension of use case 1 but takes into account that spigots can be grouped together in blocks of 4 This behavior is controlled by the Link page see Link Control on page 110 Use Case 3 12G SDI 1 ST2110 12G SDI effectively carries 4 3G SDI sub images links over a 12G physical interface Here Link 1 is considered to be the master and Links 2 3 and 4 are considered to be slav...

Page 79: ... so would subsequently fail 2 PLUS if the card is in Make Before Break mode then for every simultaneous change the stream count is 2 not 1 for duration of the change 3 PLUS there is an IP Receiver hardware limitation on the IQUCP25 and IQUCP50 as to the number of streams that can be processed concurrently This is captured in the table below Use Case 5 4 SD HD 3G 1 ST2110 In this use case a UHD sig...

Page 80: ... The following configurations are available when using the IQUCP2500 rear I O FECa a 10GbE interfaces do not support FEC SDI Format SDI Interface Number of IP Interfacesb b This applies in both directions unless specified otherwise RX IP Receive side only TX IP Transmit side only Options 0 16 0 4 4 12 8 8 8 0 12 4 16 0 None RS RS FEC FC FC FEC SD 3G SD HD 3G SD UHD SD HD 3G 12G 1 SDI 1 BNC 4 SDI 4...

Page 81: ...urations Use Case Available Configurations Use Case 1 Use Case 2 Linked Mode 8 8 FC SD 3G 1 SDI 1 2022 6 1 2110 20 30 40 16 0 FC SD 3G 1 SDI 1 2022 6 1 2110 20 30 40 8 0 FC SD 3G 1 SDI 1 VC2 1 2110 30 40 0 8 FC SD 3G 1 SDI 1 VC2 1 2110 30 40 12 4 FC SD 3G 1 SDI 1 2022 6 1 2110 20 30 40 4 12 FC SD 3G 1 SDI 1 2022 6 1 2110 20 30 40 4 4 FC SD 3G 1 SDI 1 VC2 1 2110 30 40 8 8 RS SD 3G 1 SDI 1 2022 6 1 ...

Page 82: ...D UHD 1 SDI 1 2110 20 30 40 2 2 RS SD UHD 1 SDI 1 2110 20 30 40 Use Case 4 2 2 FC SD UHD 1 SDI 4 2110 20 30 40 2 2 RS SD UHD 1 SDI 4 2110 20 30 40 Use Case 5 2 2 FC SD UHD 4 SDI 2SI 1 2110 20 30 40 2 2 RS SD UHD 4 SDI 2SI 1 2110 20 30 40 Use Case Available Configurations ...

Page 83: ...D 3G 1 SDI 1 2022 6 1 2110 20 RX 30 40 8 0 RS SD 3G 1 SDI 1 2110 20 30 40 FS 8 8 RS SD 3G 1 SDI 1 2022 6 RX 1 2110 20 30 40 16 0 RS SD 3G 1 SDI 1 2110 20 30 40 0 16 RS SD 3G 1 SDI 1 2022 6 1 2110 20 30 40 12 4 RS SD 3G 1 SDI 1 2022 6 RX 1 2110 20 30 40 4 12 RS SD 3G 1 SDI 1 2022 6 RX 1 2110 20 30 40 8 8 RS SD 3G 1 SDI 1 2022 6 1 2110 20 RX 30 40 16 0 RS SD 3G 1 SDI 1 2022 6 1 2110 30 40 12 4 RS SD...

Page 84: ...HD 1 SDI 4 2022 6 RX 4 2110 20 30 40 4 0 RS SD UHD 1 SDI 4 2110 20 30 40 0 4 RS SD UHD 1 SDI 4 2022 6 4 2110 20 30 40 2 2 RS SD UHD 1 SDI 4 2022 6 4 2110 20 RX 30 40 4 0 RS SD UHD 1 SDI 4 2022 6 4 2110 30 40 Use Case 5 2 2 FC SD UHD 4 SDI 2SI 1 2110 20 30 40 4 0 FC SD UHD 4 SDI 2SI 1 2110 20 30 40 0 4 FC SD UHD 4 SDI 2SI 1 2110 20 30 40 2 2 RS SD UHD 4 SDI 2SI 1 2110 20 30 40 4 0 RS SD UHD 4 SDI 2...

Page 85: ...eck boxes to enable the network interfaces on which PTP is supported Enable check boxes as required Ethernet 1 represents the rear panel SFP1 connection Ethernet 2 represents the rear panel SFP2 connection See Connections and Cabling on page 53 for connector information The Preference pulldown sets the primary interface to use If the primary interface fails the alternate interface if enabled will ...

Page 86: ... it fails over again Ethernet 1 If Ethernet 1 is available it has priority Thus if we have failed from Ethernet 1 to Ethernet 2 as soon as Ethernet 1 becomes available again we will switch back Ethernet 2 as per Ethernet 1 but for Ethernet 2 PTP Configuration Select values from the PTP Domain and PTP Delay Request Frequency drop down lists as required Type the appropriate IP number into the PTP Mu...

Page 87: ...t Lock Time when PTP last lost lock 1 Step syncs Increments on reception of Sync message that has the twoStepFlag false 2 Step Syncs Increments on reception of Sync message that has the twoStepFlag true Follow Ups Increments on reception of every follow_up message Delay Requests Increments on reception of every delay_req message Delay Responses Increments on reception of every delay_resp message A...

Page 88: ...andmaster and the UCP local clock If locked this number will be small Sync Interval From IEEE1588 7 7 2 1 For each of the message types Announce Sync Delay_Req and Pdelay_Req the mean time interval between successive messages shall be represented as the logarithm to the base 2 of this time interval measured in seconds on the local clock of the device sending the message The values of these logarit...

Page 89: ...ndmasters in the system Clock Blips This increments if the local clock offset is 300ns 300ns Delay Blips This increments if the network delay is 120 or 80 of the previous value Correction Blips Uses the correctionField in the header of delay_resp message from the grandmaster From IEEE1588 13 3 2 7 The correctionField is the value of the correction measured in nanoseconds and multiplied by 65536 Fo...

Page 90: ...eak around the 0ns level The Histogram Panel is located to the below the Status panel Figure 6 5 Time Sync Status Information Histogram Visible Clocks Panel Located to the below the Histogram panel this shows a list of available network clocks and the operational parameters for each clock ...

Page 91: ...flow Parameter Description TPG Select the video standard of the moving color bars test pattern to apply to the spigot from the drop down list Select None to turn off the test pattern Audio Freq Select the audio frequency to apply to the spigot from the drop down list Caption Type a caption max 19 characters to optionally be displayed with the test pattern Audio dB Select the dB level to apply to t...

Page 92: ...on a spigot by spigot basis Figure 6 7 Receiver TPG Page The following options are available for each spigot If a test pattern is applied the spigot cannot be used for streaming any other IP flow Parameter Description TPG Enable Set to enable TPG on this spigot Caption Enter a caption for the spigot optional Show Caption Set to overlay the caption on the video essence ...

Page 93: ...rors Clear All RTP Counts Counts jumps in an Real time Transport Protocol RTP packet ID sequence in an IP flow This indicates any lost dropped or out of sequence RTP packets These counters are found on RTP Receiver and Ethernet pages Clear All MAC Error Counts Counts packets marked as bad for example for a data packet CRC error Such an error is normally also accompanied by an RTP error because a p...

Page 94: ... available The FEC to be used is selected through the Card Firmware Software Version options on the Configuration page see Configuration on page 75 for more information Figure 6 9 FEC Page 1 Ensure the network switch you plan to use supports CL91 RS FEC For example for Cisco products see https www cisco com c en us td docs switches datacenter aci apic sw kb b_Cisco_ACI_and_Forward_ Error_Correctio...

Page 95: ...tium Schedule 3 Status Displays lock status for each SFP FEC Stats When Enable Stats is set this displays the number of corrected and uncorrected errors received through the SFPs Click Clear Count to zero the counters FEC Logging Information on several parameters can be made available to a logging device connected to the RollCall network Individually set the log fields to activate logging as requi...

Page 96: ...IS 05 for connection management Furthermore it supports AMWA BCP 002 recommendations for Grouping NMOS Resources UCP 3901 IQUCP25 IQUCP50 relies on an external NMOS registry that is used to register NMOS devices PREREQUISITE A working NMOS registry service must be available on the network Entries for your NMOS registries have been added to the network DNS server This enables automatic DNS SD disco...

Page 97: ...NMOS registry Interface Select the network interface to be used to connect to the NMOS registry Auto Searches through each network interface looking for the NMOS registry This mode automatically fails over to the next available network interface if connection to the NMOS registry is lost Ethernet 1 Represents the cards s SFP1 connection Ethernet 2 Represents the card s SFP2 connection Ethernet Gb ...

Page 98: ...t fields 3 When all the required values have been entered click Restart to power cycle the UCP 3901 IQUCP Card IP Senders and Receivers will then automatically generate labels as defined The Sender Pattern Receiver Pattern Fields Leaving the Sender Pattern Receiver Pattern fields empty will result in the default text string labels for IP Senders Receivers being used If a minimum of one variable is...

Page 99: ...t number starting from s_snum or r_snum flow Flow number flowalt Flow number with alternate formatting Restarts at 1 for each flow format type fmt Flow format type Uses one of sf_v1 sf_v2 sf_v3 sf_a sf_d rf_v1 rf_a or rf_d See below for more information Variable Description sf_v1 Sender 2022 6 format description Default Video sf_v2 Sender 2110 20 format description Default VideoAlt sf_v3 Sender VC...

Page 100: ...Default Values The default description values listed above may be updated if required To do this simply overwrite the default value as displayed in the Sender Receiver Variables fields with the required value This new value will then become the default ...

Page 101: ...UCP25 IQUCP50 defaults to use DHCP for Ethernet port address negotiation but this can be overridden and a static IP address can be specified if required The Ethernet configuration for these ports can also be set through the frame s control panel This is useful when the card is first installed in the frame to make it quickly operational See Local control using the Densité frame control panel to set...

Page 102: ...k Restart Click when the New Mode setting is changed for this to take effect Only make this change during off hours as this can take up to 30 seconds to complete MAC Address Shows the Ethernet port s MAC Address Mode Shows the Ethernet port s current operating mode DHCP or Static See New Mode to set the operating mode Link Status Shows the Ethernet port s connections status with the network switch...

Page 103: ...o the network IP switch ID Shows the IP switch ID Port ID Shows the IP switch port ID Port VLAN Shows the VLAN ID number used by the network interface All Traffic Shows the Ethernet port s bandwidth Capacity current data rate Actual Used and the remaining available Free Click Enable Stats to activate CPU Traffic Shows information about traffic going through the card Parameter Description ...

Page 104: ...net 1 and 2 RTP Sender The RTP Sender page displays the amount of data transmitted on a spigot by spigot basis Units are megabits per second Figure 6 12 Ethernet 1 2 RTP Sender Page Parameter Description Enable Stats Set to display the amount of data transmitted ...

Page 105: ... loss plus any unwanted multicast traffic on a spigot by spigot basis Units are megabits per second Figure 6 13 Ethernet 1 2 RTP Receiver Page Parameter Description Enable Stats Set to display the amount of data received Clear RTP Count Click to zero RTP Sequence Discontinuity counters Clear Error Count Click to zero Error counters ...

Page 106: ...xample A 172 19 164 21 B 172 19 166 22 GV Orbit RollCall assigns a source address for a flow based on the media interface address and if you tried to route a source from such a misconfigured card the destination card then complains that the source being on 164 instead of 166 If you see unexpected mutlicast traffic you need to identify and resolve the offending source flows Multicast Drop Rate The ...

Page 107: ...tion on the reception of video IP flows on network interfaces 1 and 2 on a spigot by spigot basis Units are megabits per second Figure 6 14 Ethernet RTP Receiver Video Stats Page Parameter Description Enable Stats Set to display values Clear All RTP Count Click to zero RTP Discontinuity counters for each Ethernet input ...

Page 108: ...ys information on the RTP data received on network interfaces 1 and 2 on a spigot by spigot basis Units are megabits per second Figure 6 15 Ethernet RTP Receiver Audio Stats Page Parameter Description Enable Stats Set to display values Clear ETH 1 RTP Counts Clear ETH 2 RTP Counts Click to zero RTP Discontinuity counters for each Ethernet input ...

Page 109: ...isplays information on the metadata received through RTP on each Ethernet input Units are megabits per second Figure 6 16 Ethernet RTP Receiver Meta Stats Page Parameter Description Enable Stats Set to display values Clear All RTP Counts Click to zero RTP Discontinuity counters for each Ethernet input ...

Page 110: ...ble on the rear panel see For the UCP 3901 12G 3G HD SD SDI I O Serial digital video inputs outputs 4 on page 34 and 3G HD SD SDI I O Serial digital video inputs outputs 12 on page 35 For the IQUCP25 IQUCP50 Images of Rear Panel Connectors on page 46 Enable Enable the quartet of spigots to be used for UHD Quad Links as required Set Enable For non 12G configurations where link control is to treat e...

Page 111: ...ots 13 to 16 3 Deselect the SDQS check boxes to use two sample Interleave 2SI Disable SDI Sync Bit Some older SDI receiving equipment may not support sync bit insertion When transmitting signals to these devices sync bit insertion can be disabled by setting the boxes as required UHD ST352 2SI SDQS Set the quad link signal type when UHD Links is set to Enable 2SI The linked output is handled as 2SI...

Page 112: ...ay between the four streams that would create visible glitches between the four quadrants The following shows the typical video stream composition of a 4K quad link display PREREQUISITES Configure each of the four UCP 3901 IQUCP25 IQUCP50 spigots that are to receive send the four quad link images These links are assigned in groups of 4 as shown by the Spigots parameter For example Spigots 1 to 4 S...

Page 113: ... For the UCP 3901 12G 3G HD SD SDI I O Serial digital video inputs outputs 4 on page 34 and 3G HD SD SDI I O Serial digital video inputs outputs 12 on page 35 For the IQUCP25 IQUCP50 Images of Rear Panel Connectors on page 46 ...

Page 114: ... video signal meets the BT 2100 standard HDR PQ the Perceptual Quantizer input video signal meets the SMPTE ST 2084 standard Other Other than an option shown above Colorimetry BT709 the input video signal s color gamut meets the Rec 709 standard BT2020 the input video signal s color gamut meets the Rec 2020 standard Other Other than an option shown above Color Space YCbCr the input video signal s ...

Page 115: ...ng to SMPTE RP 2077 This is also called computer RGB 10 bit the standard 64 to 940 image mapping range This is also called studio RGB Take Click to apply new setting The HDR parameters can be set for receiver spigots only Sender spigots show the current stream s status Parameter Description ...

Page 116: ...chosen video reference signal See Genlock in Configuration on page 75 Genlock Timing H Offset Horizontal timing offset in pixels with respect to the chosen video reference signal See Genlock in Configuration on page 75 Receiver Packet Buffer Frames Delay The receiver packet buffer provides additional buffering for a received IP flow Typically this is required where the IP flow is bursty in nature ...

Page 117: ... The input signals will be synchronized and realigned with respect to the chosen video reference signal See Genlock in Configuration on page 75 Parameter Description Enable Set to enable frame synchronization on this spigot V Offset lines Vertical timing offset in lines with respect to the chosen video reference signal See Genlock in Configuration on page 75 H Offset pixels Horizontal timing offse...

Page 118: ...kip RepeatPeriod Freeze on Input Error OFF Input ALL ALL ALL N A None 3G Level B DL 12G 1 frame Last valid frame 3G Level A 1 frame Last valid frame Quad Link 3G Level A 1 frame Last valid frame 3G Level B DL 2 frames Last valid frame Quad Link 3G Level B DL 2 frames Last valid frame Audio PCM N A Tracking during 15 seconds per frame Muted Non PCM N A Instant catch up Muted Metadata ALL N A Lost w...

Page 119: ...for example at receiving or destination spigots When the video input switches to another source an audio V fade can be used to reduce audio disturbances at switch over When Enable is set the audio will fade down on input loss and perform an audio V fade down then up during input switching Figure 6 21 Audio V Fade Page ...

Page 120: ...e to signal loss Select as required Figure 6 22 Input Loss Control Page Options upon signal loss are Option Operation Freeze Picture will freeze Black Picture will cut to black TPG Picture will be replaced by a test pattern output as set on the Sender TPG page See Sender TPG Test Pattern Generator on page 91 for more information ...

Page 121: ... BNC input output each spigot is available on the rear panel see For the UCP 3901 12G 3G HD SD SDI I O Serial digital video inputs outputs 4 on page 34 and 3G HD SD SDI I O Serial digital video inputs outputs 12 on page 35 For the IQUCP25 IQUCP50 Images of Rear Panel Connectors on page 46 Note The pages shown here may differ from those seen on your particular system dependingonthemodelandconfigura...

Page 122: ...ing SDC Input Spigots Input Spigots Input spigots are defined by selecting the appropriate firmware version on the Configuration page See Configuration on page 75 for more information Figure 6 23 Typical Input Spigot Page ...

Page 123: ...27 for this mode of operation BNC Associated HD BNC connector on the rear panel See also For the UCP 3901 12G 3G HD SD SDI I O Serial digital video inputs outputs 4 on page 34 and 3G HD SD SDI I O Serial digital video inputs outputs 12 on page 35 For the IQUCP25 IQUCP50 Images of Rear Panel Connectors on page 46 Status Current spigot s status OK signal good FAIL signal not detected WARN TPG a test...

Page 124: ...r of audio flows on this spigot to use Options are 1 flow of 16 channels 2 flows of 8 channels each 4 flows of 4 channels each Note these flows are contiguous so selecting 1 means Flow 1 is used selecting 2 means Flows 1 and 2 are used and selecting 4 means Flows 1 to 4 are used This setting impacts how Audio Shuffling works See Audio Shuffle on page 131 for more information Sender Ext Headers Ext...

Page 125: ...tails to be defined for the selected spigot IP flow settings may be set through GV Orbit The Current column shows the present value To manually set the multicast details for the spigot set the value in the New column and click to save the details or to return to the preset default value Enter Multicast IP and Multicast Port details as required Enter the appropriate details in the Source IP and Sou...

Page 126: ...ils 1 Enter IP address and IP port number details in the New settings column as required Click S or press the enter key to enter each new value 2 Select the Flow Type 3 Click Packetizer Stats to view network statistics for an outgoing flow if required 4 Click Take ...

Page 127: ...cting the appropriate firmware version on the Configuration page See Configuration on page 75 for more information Figure 6 24 Typical Output Spigot Page Note If spigots are linked for UHD traffic only the Master spigots are shown on the main menu Slave spigots are not shown ...

Page 128: ...trl GV Orbit RCStart The default at module startup Streaming Set the Ethernet connectors to use for this spigot This will also determine the bandwidth to be used Options are Dual Full redundancy to support SMPTE ST 2022 7 both Primary SFP1 and Secondary SFP2 Ethernet connectors are used All bandwidth of both Ethernet connectors are used See Cabling to Support SMPTE ST 2022 7 on page 55 To support ...

Page 129: ...ition but requires more bandwidth Break before Make simply swaps the output s destination without buffering Select the required mode from the drop down list Num Audio Flows Select the number of audio flows on this spigot to use Options are 1 flow of 16 channels 2 flows of 8 channels each 4 flows of 4 channels each Note these flows are contiguous so selecting 1 means Flow 1 is used selecting 2 mean...

Page 130: ...chieved by either explicitly setting the UCP 3901 IQUCP Card to receive a flow from itself or by using the UCP 3901 IQUCP Card s loop back router facility See Loopback Router on page 162 Flow Panes for Video Audio and Metadata Displays Video Audio and Metadata status and allows multicast IP and port details to be defined for the selected spigot IP flow settings may be set through GV Orbit The Curr...

Page 131: ...ute Tone sources Mapping presets Figure 6 25 Audio Shuffle Configuration Page showing a pass though setting Parameter Description Spigot Select Select the spigot on which you want to configure the audio options Num Audio Flows Shows the number of audio flows present on the currently selected spigot See the Num Audio Flows parameter in Input Spigots on page 122 and Output Spigots on page 127 ...

Page 132: ...etween the input audio channel and the output audio channel NOTE If a preset is selected and the routing then changed manually the Custom option will be highlighted as described above However if the routing is then changed to match a preset the Custom option remains highlighted the matching preset is NOT detected or highlighted Audio Shuffle Source Destination Channel Set the audio option Shuffle ...

Page 133: ...to account the multi flow audio operation which is set with the Num Audio Flows parameter in Input Spigots on page 122 and Output Spigots on page 127 The table below shows the source and destination mappings of the audio channels in respect to the audio shuffle page for different flow configurations SDI Audio Channel Map Num Audio Flows parameter setting Flow 1 Flow 2 Flow 3 Flow 4 1 1 to 16 2 1 t...

Page 134: ... 30 IP Out SMPTE ST 2110 30 IP In to SDI Out SDI In ST 2110 30 Out 16 16 Tone Mute Audio Shuffle Flow 1 Flow 1 Flow 2 Flow 1Flow 2Flow 3Flow 4 Num Audio Flows Parameter Setting 16 16 Mute Audio Shuffle SDI Out ST 2110 30 In Flow 1 Flow 2 Flow 1 Flow 4 Flow 3 Flow 2 Flow 1 Num Audio Flows Parameter Setting ...

Page 135: ... 6 7 8 9 10 12 12 13 14 15 16 Mute Tone 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Source Destination IP Out Flow 1 Audio Channels 1 8 IP Out Flow 2 Audio Channels 1 8 SDI In Audio Channels 1 16 Source 1 2 3 4 5 6 7 8 9 10 12 12 13 14 15 16 Mute Tone 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Source Destination IP In Flow 1 Audio Channels 1 4 IP In Flow 2 Audio Channels 1 4 IP In Flow 3 Audio Channels 1 4...

Page 136: ...onfiguration Page configuration example Source Audio Channel Description 1 to 3 5 to 7 9 13 to 15 Sent to destination channels 1 to 3 pass through Sent to destination channels 5 to 7 pass through Sent to destination channel 9 pass through Sent to destination channels 13 to 15 pass through 4 Sent to destination channels 4 8 12 and 16 10 Is muted 11 Test tone activated ...

Page 137: ... log server to use for logging Any LogServer Logging is sent to any LogServer that is discovered on the network Logging Disabled No logging is generated Logging Interface Set the network interface that has network connectivity to the log server 1G The Gb management Ethernet network This option is not to be used with IQUCP25 IQUCP50 cards Ethernet 1 The Ethernet network connected to SFP 1 Ethernet ...

Page 138: ...rmation below describes the various parameters available for logging For the UCP 3901 logging must be configured and enabled see Logging Configuration UCP 3901 Only on page 137 Figure 6 28 Logging SDI Info Page The logging page comprises three columns Logging Page Column Description SDI Change Time pane Logs the time at which the SDI input changed SDI Change Counts pane Logs number of times that t...

Page 139: ...mation should be collected Log Field Displays the name of the logging field INPUT_N_CHANGE_TIME Logs the time at which the SDI input changed INPUT_N_SDI_CHANGE_CNT Logs number of times that the SDI input has changed Where N is the input number To identify SFP 1 2 see Rear Panel and Connectors on page 32 Log Value Displays the current log value ...

Page 140: ...nd log values are listed in the Log Field and Log Value columns respectively Information on several parameters can be made available to a logging device connected to the RollCall network For the UCP 3901 logging must be configured and enabled see Logging Configuration UCP 3901 Only on page 137 Figure 6 29 Logging System Page ...

Page 141: ... version number HARDWARE_MOD Logs the hardware modification number HARDWARE_BUILD Logs the hardware build number FEATUREBOARD_VERSION Not applicable Logs the rear card daughter board version number FEATUREBOARD_MOD Not applicable Logs the rear card daughter board modification number FEATUREBOARD_BUILD Not applicable Logs the rear card daughter board build number FIRMWARE_VERSION Logs the FPGA vers...

Page 142: ...ence to any other source PTP Multicast Card is synchronizing to a PTP grandmaster clock using multicast network messages PTP Unicast As PTP Multicast but using the delay request Reply messages are unicast to minimize network traffic NTP Card clock is synchronized to an NTP clock Generally less precise than PTP TIMESYNC_N_NETWORK Logs the network port currently being used for synchronization for UC...

Page 143: ...nd the grandmaster time Should be close to zero once card has synchronized TIMESYNC_N_STDV_ERROR Logs the standard deviation in the average error TIMESYNC_N_GRANDMASTER Logs the identity of network clock acting as PTP grandmaster This is the source of the PTP synchronization messages used by all PTP slave clocks on the network If there are multiple grandmasters they should negotiate between themse...

Page 144: ...isconnected Urgent maintenance procedures must be considered If this alarm has been raised the fan on the UCP 3901 card may have to be replaced See Cooling Fan Operational Assessment on page 320 DENSITE_CONTROLLER_STATUS For the UCP 3901 Card only Reports the connection status of the Densité frame s controller card to the UCP 3901 card OK The UCP 3901 card has successfully connected to the Densité...

Page 145: ...the RollCall network For the UCP 3901 logging must be configured and enabled see Logging Configuration UCP 3901 Only on page 137 Figure 6 30 Logging Network Page The logging page comprises three columns Enable check boxes to activate log fields as required Logging Page Column Description Log Enable Select the check boxes that correspond to the parameters for which log information should be collect...

Page 146: ...T_N_STATE Logs the Ethernet connection state Valid values are Active WARN Inactive LAN_PORT_N_TRAFFIC_IN Logs speed of traffic received by the Ethernet port Values are reported in kbps Mbps or Gbps as appropriate LAN_PORT_N_TRAFFIC_OUT Logs speed of traffic transmitted by the Ethernet port Values are reported in Kbps Mbps or Gbps as appropriate LAN_PORT_N_CPU_TRAF_IN_STATE Logs whether the flow of...

Page 147: ... Valid values are UP DOWN LAN_PORT_N_SWITCH_NAME Logs name of the network switch that the card is connected to LAN_PORT_N_SWITCH_CHASSIS_ID Logs name of the network switch s chassis ID that the card is connected to LAN_PORT_N_SWITCH_PORT_ID Logs Port ID of the network switch the card is connected to LAN_PORT_N_SWITCH_PORT_VLAN Logs name of the VLAN that the card is connected to Parameter Descripti...

Page 148: ...QUCP25 IQUCP50 cards as this port is unused with these models Figure 6 31 Logging Network Page The logging page comprises three columns Enable check boxes to activate log fields as required Logging Page Column Description Log Enable Select the check boxes that correspond to the parameters for which log information should be collected Log Field Displays the name of the logging field Log Value Displ...

Page 149: ...c received by the Ethernet port Values are reported in kbps Mbps or Gbps as appropriate LAN_PORT_3_TRAFFIC_OUT Logs speed of traffic transmitted by the Ethernet port Values are reported in Kbps Mbps or Gbps as appropriate LAN_PORT_3_CPU_TRAF_IN_STATE Logs whether the flow of data into the CPU is satisfactory Valid values are OK WARN LOW DATA FAIL LAN_PORT_3_CPU_TRAF_OUT_STAT E Logs whether the flo...

Page 150: ...ected to the RollCall network For the UCP 3901 logging must be configured and enabled see Logging Configuration UCP 3901 Only on page 137 Figure 6 32 Logging SFP Page The logging page comprises three columns for each SFP Enable check boxes to activate log fields as required Logging Page Column Description Log Enable Select the check boxes that correspond to the parameters for which log information...

Page 151: ... of Lock FAIL TX LOL TX Loss of Lock SFP_N_STATUS continued QSFPs OK WARN Temp WARN VCC WARN RX PWR LO WARN RX PWR HI WARN TX PWR LO WARN TX PWR HI FAIL SFP Not Ready FAIL RX LOS RX Failure FAIL TX LOS TX Failure FAIL EQ Fault EQ Failure FAIL RX LOL RX Loss of Lock FAIL TX LOL TX Loss of Lock FAIL Temp FAIL VCC FAIL RX PWR LO FAIL RX PWR HI FAIL TX BIAS LO FAIL TX BIAS HI TX PWR LO TX PWR HI SFP_N...

Page 152: ...Logs voltage sensor name VOLTAGE_N_VALUE Logs current voltage reading VOLTAGE_N_STATE Logs temperature sensor state Valid values are OK WARN Low Low but in tolerance WARN High High but in tolerance SFP_N_WAVELENGTH Logs transmit wavelength in nm SFP_N_X_LASER_BIAS Logs bias level in mA SFP_N_X_TX_POWER Logs transmit power level in dBm SFP_N_X_TX_POWER_STATE Logs transmit power level Valid values a...

Page 153: ...e The logging page comprises three columns Enable check boxes to activate log fields as required Where N is the input number Logging Page Column Description Log Enable Select the check boxes that correspond to the parameters for which log information should be collected Log Field Displays the name of the logging field Log Value Displays the current log value Parameter Description TEMP_N_NAME Repor...

Page 154: ...iguration UCP 3901 Only on page 137 An additional field is provided for you to optionally specify a name for the input output Figure 6 34 Input Spigot Logging Page Figure 6 35 Output Spigot Logging Page The logging page comprises three columns Enable check boxes to activate log fields as required Logging Page Column Description Log Enable Select the check boxes that correspond to the parameters fo...

Page 155: ...ar panel See 12G 3G HD SD SDI I O Serial digital video inputs outputs 4 on page 34 and 3G HD SD SDI I O Serial digital video inputs outputs 12 on page 35 OUTPUT_N_NAME Name of the output that you have defined OUTPUT_N_STATE Valid values are OK output signal good FAIL output signal not detected WARN Freeze WARN Pattern WARN Black OUTPUT_N_TYPE Valid values are SD SDI HD SDI HD SD 3G SDI OUTPUT_N_ST...

Page 156: ...ging field Log Value Displays the current log value Parameter Description NMOS_STATUS Displays the current NMOS status Valid values are OK Off NMOS functionality is disabled OK Registered the module has been successfully added to the NMOS registry WARN Registering the module is currently being registered FAIL Unregistered the registration process has failed NMOS_REGISTRATION The current card s NMO...

Page 157: ...Y_PORT The current port number being used to connect to the NMOS registry for making queries NMOS_REGISTRATION_PORT The current port number being used to connect to the NMOS registry for making device registrations Parameter Description ...

Page 158: ... required Logging Page Column Description Log Enable Select the check boxes that correspond to the parameters for which log information should be collected Log Field Displays the name of the logging field Log Value Displays the current log value Parameter Description NVRAM_FS Logs whether the installed file system is QNX6 PowerSafe or FAT32 TOTAL_AVAILABLE_MEMORY Logs total amount of CPU memory av...

Page 159: ..._RESTORE Logs where system memory was restored from Valid values are FAT32 restored from FAT32 OK restored from QNX6 PowerSafe FAIL memory restoration failed PMIC_VERSION Logs name of the on board power management chip Parameter Description ...

Page 160: ... disabled Index This slider allows up to 32 distinct RollTrack outputs to be set up Dragging the slider selects the RollTrack Index number displayed below the slider Clicking selects the default preset value Source The source of information that triggers transmission of data is selected with this control Dragging the slider selects the RollTrack source displayed below the slider Clicking selects t...

Page 161: ...Track Output Index destination The command may be changed by typing a code into the text field and then selecting to save the selection Clicking returns to the default preset command A RollTrack command consists of two sets of numbers for example 84 156 The first number 84 is the actual RollTrack command The second number 156 is the value sent with the RollTrack command Sending A message is displa...

Page 162: ...k flows are not transmitted externally The loop back routing is all local to the UCP 3901 IQUCP Card Figure 6 39 Loopback Router Page To use the Loopback Router 1 Use the matrix radio buttons to specify which inputs should be routed to which outputs 2 Select the Video Flow to Use SMPTE 2022 2110 20 or VC2 VC2 is currently unsupported 3 Select the Primary Secondary IP fabric to use main backup 4 Wh...

Page 163: ...ay be asked for these details by Grass Valley support if you need technical assistance Parameter Description Product Name of the card Software Version Currently installed software version number Firmware Version Currently installed firmware version number Serial No Card serial number SW Build Factory software build number This number identifies all parameters of the card OS Operating system versio...

Page 164: ...wer cycles the card This will produce disturbances on the output picture Note Restarting the card will affect all outputs Defaults Provides options to reset the card to its defaults Default Settings All settings are reset to their default values except for network configuration and IP addresses Factory Defaults All settings are reset to their default values including network configuration and IP a...

Page 165: ...panel This is useful when the card is first installed in the frame to make it quickly operational See Local control using the Densité frame control panel to set the Card s IP Addresses on page 38 For a IQUCP25 IQUCP50 The Ethernet Gb page displays details and the status of the card front Ethernet port of the IQUCP25 IQUCP50 card This is for Grass Valley engineering use only The IQUCP25 IQUCP50 def...

Page 166: ...he Ethernet port s connection mode DHCP The Ethernet port uses automatic configuration obtained from the network s DHCP server Static You set a fixed Ethernet port configuration IP Address Default Gateway and Subnet Mask New settings are applied when Restart is clicked Restart Click when the New Mode setting is changed for this to take effect Only make this change during off hours as this can take...

Page 167: ...167 UCP 3901 User Manual Ethernet Arcnet Not currently used ...

Page 168: ...C Interop Interop The Interop page allows certain parameters to be changed in order to improve interoperability with third party equipment including disabling extended headers and setting payload types Figure 6 42 Interop Page ...

Page 169: ...eo Meta Frame Delay Allows a frame delay for metadata received on the spigots shown to be set Use the sliders to adjust as required Click to use the preset default value RTP Payload Types Payload Selection Set 1 Set 2 Select the appropriate set of standards to be used The set contents are displayed on the Payload Format pane Payload Format Hexadecimal code used to identify payload types SMPTE2022 ...

Page 170: ...FP Configuration Page The majority of SFPs will operate correctly with UCP 3901 IQUCP25 IQUCP50 cards without any need for adjustment Some however may need to have card parameters set a little differently If difficulties are encountered with an SFP not working as expected proceed as follows 1 Select the appropriate SFP type from the SFP Database List and click Take Verify whether the SFP is now wo...

Page 171: ...icast transmission in multicast groups and forward error correction RollCall control and monitoring compatible with standard logging and reporting features Seamless integration with GV Orbit Control Configuration Monitoring software including logging and reporting MADI Gateway MD Features Handles up to 16 MADI signals 8 in 8 out over dual 10GbE or 25GbE IP links with the option to provide MADI lin...

Page 172: ...o V Fade on page 199 Spigot Pages on page 200 Input Spigots on page 201 Output Spigots on page 206 Audio Shuffle on page 210 Logging Configuration UCP 3901 Only on page 216 Logging Input Info on page 217 Logging System on page 219 Logging Network on page 224 Logging Network 1G on page 227 Logging SFP on page 229 Logging FPGA on page 232 Logging Spigot 1 to n on page 233 Logging FEC on page 235 Log...

Page 173: ... of the Information display Figure 7 1 Information and Selection Panes Selecting the Information to Display Select MADI Status or Network Status from the Information Select pane as required The selected information type is displayed on the Information display pane When MADI Status is selected the Information display pane shows the following for each of the card s inputs and outputs M MADI signal p...

Page 174: ...lows basic card parameters to be set Figure 7 2 Configuration Page Note SDC functionality options are set here See also Upgrading the UCP 3901 IQUCP25 IQUCP50 s SDC Application on page 309 and Installing a License into a UCP 3901 IQUCP25 IQUCP50 on page 314 for more information ...

Page 175: ...m the change Interface Configuration Displays the IP address for each of the Ethernet interfaces Card Firmware Software Version Each software version contains multiple firmware images These allow different spigot input output and flow standard combinations to be selected Select the required software from the Software Version pane then select the firmware which provides the required combination of ...

Page 176: ...New pane Note that Restore and Restart buttons are displayed only when an item not currently installed is selected 2 Enable the Reset to Defaults on Restart checkbox This will cause existing details stored on the module other than network IP settings to be cleared down prior to restarting the module See Defaults on page 243 for more information 3 Click Restart to restart the module and implement a...

Page 177: ...erface and Number of IP Interfaces values are enclosed by brackets and separated by a comma and a space If required RX TX values are also enclosed by brackets and inserted after the Number of IP Interfaces values For example 8 8 25G RS 1x 2x MADI 2110 30 I O FECa a 10GbE interfaces do not support FEC SDI Format SDI Interface Number of IP Interfacesb b This applies in both directions unless specifi...

Page 178: ...ce Set the check boxes to enable the network interfaces on which PTP is supported Enable check boxes as required Ethernet 1 represents the rear panel SFP1 connection Ethernet 2 represents the rear panel SFP2 connection See Connections and Cabling on page 53 for connector information The Preference pulldown sets the primary interface to use If the primary interface fails the alternate interface if ...

Page 179: ...er again Ethernet 1 If Ethernet 1 is available it has priority Thus if we have failed from Ethernet 1 to Ethernet 2 as soon as Ethernet 1 becomes available again we will switch back Ethernet 2 as per Ethernet 1 but for Ethernet 2 PTP Configuration Select values from the PTP Domain and PTP Delay Request Frequency drop down lists as required Type the appropriate IP number into the PTP Multicast addr...

Page 180: ... locked Lost Lock Time when PTP last lost lock 1 Step syncs Increments on reception of Sync message that has the twoStepFlag false 2 Step Syncs Increments on reception of Sync message that has the twoStepFlag true Follow Ups Increments on reception of every follow_up message Delay Requests Increments on reception of every delay_req message Delay Responses Increments on reception of every delay_res...

Page 181: ...d the UCP local clock If locked this number will be small Sync Interval From IEEE1588 7 7 2 1 For each of the message types Announce Sync Delay_Req and Pdelay_Req the mean time interval between successive messages shall be represented as the logarithm to the base 2 of this time interval measured in seconds on the local clock of the device sending the message The values of these logarithmic attribu...

Page 182: ...ple grandmasters in the system Clock Blips This increments if the local clock offset is 300ns 300ns Delay Blips This increments if the network delay is 120 or 80 of the previous value Correction Blips Uses the correctionField in the header of delay_resp message from the grandmaster From IEEE1588 13 3 2 7 The correctionField is the value of the correction measured in nanoseconds and multiplied by 6...

Page 183: ...the 0ns level The Histogram Panel is located to the below the Status panel Figure 7 5 Time Sync Status Information Histogram Visible Clocks Panel Located to the below the Histogram panel this shows a list of available network clocks and the operational parameters for each clock ...

Page 184: ...d Clear All RTP Counts Counts jumps in a Real time Transport Protocol RTP packet ID sequence in an IP flow This indicates any lost dropped or out of sequence RTP packets These counters are found on RTP Receiver and Ethernet pages Clear All MAC Error Counts Counts packets marked as bad for example for a data packet CRC error Such an error is normally also accompanied by an RTP error because a packe...

Page 185: ...ts CL91 RS FEC For example for Cisco products see https www cisco com c en us td docs switches datacenter aci apic sw kb b_Cisco_ACI_and_Forward_ Error_Correction html Parameter Description FC FEC displayed only if a relevant configuration is in use See Configuration on page 174 for more information Allows low latency FC FEC error correction to be used Options are On Off RS FEC displayed only if a...

Page 186: ...several parameters can be made available to a logging device connected to the RollCall network Individually set the log fields to activate logging as required Fec N Corrected Errors Number of corrected errors for FEC N Fec N Uncorrected Errors Number of uncorrected errors for FEC N The available log fields are shown in the table below Log Field Description FEC_N_CORRECTED_ERRORS Number of correcte...

Page 187: ...for connection management Furthermore it supports AMWA BCP 002 recommendations for Grouping NMOS Resources UCP 3901 IQUCP25 relies on an external NMOS registry that is used to register NMOS devices PREREQUISITE A working NMOS registry service must be available on the network Entries for your NMOS registries have been added to the network DNS server This enables automatic DNS SD discovery Contact y...

Page 188: ...r the NMOS registry Interface Select the network interface to be used to connect to the NMOS registry Auto Searches through each network interface looking for the NMOS registry This mode automatically fails over to the next available network interface if connection to the NMOS registry is lost Ethernet 1 Represents the cards s SFP1 connection Ethernet 2 Represents the card s SFP2 connection Ethern...

Page 189: ...on below the input fields 3 When all the required values have been entered click Restart to power cycle the UCP 3901 IQUCP Card IP Senders and Receivers will then automatically generate labels as defined The Sender Pattern Receiver Pattern Fields Leaving the Sender Pattern Receiver Pattern fields empty will result in the default text string labels for IP Senders Receivers being used If a minimum o...

Page 190: ...he following optional variables are available Variable Description dev Device label For example Camera1 spig Spigot number starting from s_snum or r_snum flow Flow number flowalt Flow number with alternate formatting Restarts at 1 for each flow format type fmt Flow format type Uses one of sf_v1 sf_v2 sf_v3 sf_a sf_d rf_v1 rf_a or rf_d See below for more information Variable Description sf_v1 Sende...

Page 191: ...ly overwrite the default value as displayed in the Sender Receiver Variables fields with the required value This new value will then become the default s_pad Sender number padding Prefixes small numbers with leading zeroes Default 2 r_pad Receiver number padding Prefixes small numbers with leading zeroes Default 2 Variable Description ...

Page 192: ...aces The UCP 3901 IQUCP25 defaults to use DHCP for Ethernet port address negotiation but this can be overridden and a static IP address can be specified if required The Ethernet configuration for these ports can also be set through the frame s control panel This is useful when the card is first installed in the frame to make it quickly operational See Local control using the Densité frame control ...

Page 193: ...ck when the New Mode setting is changed for this to take effect Only make this change during off hours as this can take up to 30 seconds to complete MAC Address Shows the Ethernet port s MAC Address Mode Shows the Ethernet port s current operating mode DHCP or Static See New Mode to set the operating mode Link Status Shows the Ethernet port s connections status with the network switch UP Connectio...

Page 194: ... assigned to the network IP switch ID Shows the IP switch ID Port ID Shows the IP switch port ID Port VLAN Shows the VLAN ID number used by the network interface All Traffic Shows the Ethernet port s bandwidth Capacity current data rate Actual Used and the remaining available Free Click Enable Stats to activate CPU Traffic Shows information about traffic going through the card Parameter Descriptio...

Page 195: ... Sender The RTP Sender page displays the amount of data transmitted on a spigot by spigot basis Units are megabits per second Figure 7 10 Ethernet 1 2 RTP Sender Page Parameter Description Enable Stats Set to display the amount of data transmitted ...

Page 196: ...ails of packet loss plus any unwanted multicast traffic on a spigot by spigot basis Units are megabits per second Figure 7 11 Ethernet 1 2 RTP Receiver Page Parameter Description Enable Stats Set to display the amount of data received Clear RTP Count Click to zero RTP Sequence Discontinuity counters Clear Error Count Click to zero Error counters ...

Page 197: ...164 21 B 172 19 166 22 GV Orbit RollCall assigns a source address for a flow based on the media interface address and if you tried to route a source from such a misconfigured card the destination card then complains that the source being on 164 instead of 166 If you see unexpected mutlicast traffic you need to identify and resolve the offending source flows Multicast Drop Rate The wasted network b...

Page 198: ... information on the RTP data received on network interfaces 1 and 2 on a spigot by spigot basis Units are megabits per second Figure 7 12 Ethernet RTP Receiver Audio Stats Page Parameter Description Enable Stats Set to display values Clear ETH 1 RTP Counts Clear ETH 2 RTP Counts Click to zero RTP Discontinuity counters for each Ethernet input ...

Page 199: ...for example at receiving or destination spigots When the video input switches to another source an audio V fade can be used to reduce audio disturbances at switch over When Enable is set the audio will fade down on input loss and perform an audio V fade down then up during input switching Figure 7 13 Audio V Fade Page ...

Page 200: ... of Rear Panel Connectors on page 46 Pairing Inputs and Outputs for Redundancy Inputs and outputs can be paired together to provide redundancy Each pair can be individually enabled The pairings when enabled link Inputs 1 2 3 4 5 6 7 8 and link Outputs 9 10 11 12 13 14 15 16 To enable pairing see the Pairing parameter on each odd numbered spigot page Note The pages shown here may differ from those ...

Page 201: ... User Manual Input Spigots Input spigots are defined by selecting the appropriate firmware version on the Configuration page See Configuration on page 174 for more information Figure 7 14 Typical Input Spigot Page ...

Page 202: ...eaming Set the redundancy options for this spigot This will also determine the bandwidth to be used Options are Dual Full redundancy to support SMPTE ST 2022 7 both Primary SFP1 and Secondary SFP2 Ethernet connectors are used Bandwidth is split between the Primary and Secondary See Cabling to Support SMPTE ST 2022 7 on page 55 To support redundancy you must set the Flow Type to 2110 for both the p...

Page 203: ...ved on this spigot Audio Tone Set the tone frequency and level to be used when a test tone is enabled in the Audio Shuffle page See Audio Shuffle on page 210 Sender Ext Headers Extended header operation can be set for TR 03 TR 04 compatibility Extended headers provide in band metadata regarding the flow and its format and are applicable to ST 2110 only If third party equipment is unable to support...

Page 204: ... connection usually SFP2 Flow Panes for Audio Displays Audio status and allows multicast IP and port details to be defined for the selected spigot IP flow settings may be set through GV Orbit The Current column shows the present value To manually set the multicast details for the spigot set the value in the New column and click to save the details or to return to the preset default value Enter Mul...

Page 205: ...205 UCP 3901 User Manual 3 Click Packetizer Stats to view network statistics for an outgoing flow if required 4 Click Take ...

Page 206: ...age 174 for more information Figure 7 15 Typical Output Spigot Page Parameter Description Spigot pane The Spigot pane provides basic configuration for the selected Spigot Click Take to apply any changes made in this pane Direction Displays spigot direction Input This spigot is a sender See Input Spigots on page 201 for this mode of operation Output This spigot is a receiver ...

Page 207: ...ither Ethernet connector SFP1 SFP2 and so half of the available bandwidth A Primary SFP1 Ethernet connector only and so half of the available bandwidth B Secondary SFP2 Ethernet connector only and so half of the available bandwidth off The stream is disabled See Rear Panel and Connectors on page 32 for SFP connector locations Receiver MADI Format Set the number of MADI channels to process 64 chann...

Page 208: ...ns Flows 1 to 4 are used Pairing Set the pairing of output connections for redundancy n the current main odd numbered spigot n 1 the next available even numbered spigot that provides redundancy Only odd numbered spigots can be paired with the next even numbered spigot No The output is non redundant Yes The output is paired with the next output for redundancy Active Channels Shows the current numbe...

Page 209: ...Loop back can be achieved by explicitly setting the UCP 3901 IQUCP Card to receive a flow from itself Flow Panes for Audio Displays Audio status and allows multicast IP and port details to be defined for the selected spigot IP flow settings may be set through GV Orbit The Current column shows the present value To manually set the multicast details for the spigot set the value in the New column and...

Page 210: ...ction by Spigot Number on page 200 Mapping presets Figure 7 16 Audio Shuffle Configuration Page showing a pass though setting Parameter Description Spigot Select Select the spigot on which you want to configure the audio options Num Audio Flows Shows the number of audio flows present on the currently selected spigot See the Num Audio Flows parameter in Input Spigots on page 201 and Output Spigots ...

Page 211: ...huffle is enabled There is no longer a 1 1 correspondence between the input audio channel and the output audio channel NOTE If a preset is selected and the routing then changed manually the Custom option will be highlighted as described above However if the routing is then changed to match a preset the Custom option remains highlighted the matching preset is NOT detected or highlighted Audio Shuff...

Page 212: ...low audio operation which is set with the Num Audio Flows parameter in Input Spigots on page 201 and Output Spigots on page 206 The table below shows the source and destination mappings of the audio channels in respect to the audio shuffle page for different flow configurations MADI Audio Channel Map Num Audio Flows parameter setting Flow 1 Flow 2 Flow 3 Flow 4 1 1 to 64 2 1 to 32 33 to 64 4 1 to ...

Page 213: ...PTE ST 2110 30 IP In to MADI Out MADI In ST 2110 30 Out 64 64 Tone Mute Audio Shuffle Flow 1 Flow 1 Flow 2 Flow 1Flow 2Flow 3Flow 4 Num Audio Flows Parameter Setting 64 64 Mute Audio Shuffle MADI Out ST 2110 30 In Flow 1 Flow 2 Flow 1 Flow 4 Flow 3 Flow 2 Flow 1 Num Audio Flows Parameter Setting ...

Page 214: ... 14 15 16 Source IP Out Flow 1 Audio Channels 1 to 32 IP Out Flow 2 Audio Channels 33 to 64 SDI In MADI Audio Channels 1 to 64 64 Use the Scroll Bars to view all input and output channels Destination IP In Flow 1 Audio Channels 1 to 16 IP In Flow 2 Audio Channels 1 to 16 IP In Flow 3 Audio Channels 1 to 16 IP In Flow 4 Audio Channels 1 to 16 SDI Out MADI Audio Channels 1 to 64 Source 1 2 3 4 5 6 7...

Page 215: ... Page configuration example Source Audio Channel Description 1 to 3 5 to 7 9 13 to 15 Sent to destination channels 1 to 3 pass through Sent to destination channels 5 to 7 pass through Sent to destination channel 9 pass through Sent to destination channels 13 to 15 pass through 4 Sent to destination channels 4 8 12 and 16 10 Is muted 11 Test tone activated ...

Page 216: ...fic name of the log server to use for logging Any LogServer Logging is sent to any LogServer that is discovered on the network Logging Disabled No logging is generated Logging Interface Set the network interface that has network connectivity to the log server 1G The Gb management Ethernet network This option is not to be used with IQUCP25 cards Ethernet 1 The Ethernet network connected to SFP 1 Et...

Page 217: ...on below describes the various parameters available for logging For the UCP 3901 logging must be configured and enabled see Logging Configuration UCP 3901 Only on page 216 Figure 7 19 Logging SDI Info Page The logging page comprises three columns Logging Page Column Description Input Change Time pane Logs the time at which the input changed Input Change Counts pane Logs number of times that the in...

Page 218: ...h log information should be collected Log Field Displays the name of the logging field INPUT_N_CHANGE_TIME Logs the time at which the SDI input changed INPUT_N_CHANGE_CNT Logs number of times that the SDI input has changed Where N is the input number To identify SFP 1 2 see Rear Panel and Connectors on page 32 Log Value Displays the current log value ...

Page 219: ...alues are listed in the Log Field and Log Value columns respectively Information on several parameters can be made available to a logging device connected to the RollCall network For the UCP 3901 logging must be configured and enabled see Logging Configuration UCP 3901 Only on page 216 Figure 7 20 Logging System Page ...

Page 220: ...re modification number HARDWARE_BUILD Logs the hardware build number FEATUREBOARD_VERSION Not applicable Logs the rear card daughter board version number FEATUREBOARD_MOD Not applicable Logs the rear card daughter board modification number FEATUREBOARD_BUILD Not applicable Logs the rear card daughter board build number FIRMWARE_VERSION Logs the FPGA version number UPTIME Logs the time since the la...

Page 221: ... to a PTP grandmaster clock using multicast network messages PTP Unicast As PTP Multicast but using the delay request Reply messages are unicast to minimize network traffic NTP Card clock is synchronized to an NTP clock Generally less precise than PTP TIMESYNC_N_NETWORK Logs the network port currently being used for synchronization for UCP 3901 IQUCP25 cards dependent on the choice of interfaces m...

Page 222: ... time and the grandmaster time Should be close to zero once card has synchronized TIMESYNC_N_STDV_ERROR Logs the standard deviation in the average error TIMESYNC_N_GRANDMASTER Logs the identity of network clock acting as PTP grandmaster This is the source of the PTP synchronization messages used by all PTP slave clocks on the network If there are multiple grandmasters they should negotiate between...

Page 223: ...ted Urgent maintenance procedures must be considered If this alarm has been raised the fan on the UCP 3901 card may have to be replaced See Cooling Fan Operational Assessment on page 320 DENSITE_CONTROLLER_STATUS For the UCP 3901 Card only Reports the connection status of the Densité frame s controller card to the UCP 3901 card OK The UCP 3901 card has successfully connected to the Densité frame s...

Page 224: ...cted to the RollCall network For the UCP 3901 logging must be configured and enabled see Logging Configuration UCP 3901 Only on page 216 Figure 7 21 Logging Network Page The logging page comprises three columns Enable check boxes to activate log fields as required Logging Page Column Description Log Enable Select the check boxes that correspond to the parameters for which log information should be...

Page 225: ... Logs the Ethernet connection state Valid values are Active WARN Inactive LAN_PORT_N_TRAFFIC_IN Logs speed of traffic received by the Ethernet port Values are reported in kbps Mbps or Gbps as appropriate LAN_PORT_N_TRAFFIC_OUT Logs speed of traffic transmitted by the Ethernet port Values are reported in Kbps Mbps or Gbps as appropriate LAN_PORT_N_CPU_TRAF_IN_STATE Logs whether the flow of data int...

Page 226: ...et link Valid values are UP DOWN LAN_PORT_N_SWITCH_NAME Logs name of the network switch that the card is connected to LAN_PORT_N_SWITCH_CHASSIS_ID Logs name of the network switch s chassis ID that the card is connected to LAN_PORT_N_SWITCH_PORT_ID Logs Port ID of the network switch the card is connected to LAN_PORT_N_SWITCH_PORT_VLAN Logs name of the VLAN that the card is connected to Parameter De...

Page 227: ...P25 card as this port is unused with this model Figure 7 22 Logging Network Page The logging page comprises three columns Enable check boxes to activate log fields as required Logging Page Column Description Log Enable Select the check boxes that correspond to the parameters for which log information should be collected Log Field Displays the name of the logging field Log Value Displays the curren...

Page 228: ...of traffic received by the Ethernet port Values are reported in kbps Mbps or Gbps as appropriate LAN_PORT_3_TRAFFIC_OUT Logs speed of traffic transmitted by the Ethernet port Values are reported in Kbps Mbps or Gbps as appropriate LAN_PORT_3_CPU_TRAF_IN_STATE Logs whether the flow of data into the CPU is satisfactory Valid values are OK WARN LOW DATA FAIL LAN_PORT_3_CPU_TRAF_OUT_STAT E Logs whethe...

Page 229: ...o the RollCall network For the UCP 3901 logging must be configured and enabled see Logging Configuration UCP 3901 Only on page 216 Figure 7 23 Logging SFP Page The logging page comprises three columns for each SFP Enable check boxes to activate log fields as required Logging Page Column Description Log Enable Select the check boxes that correspond to the parameters for which log information should...

Page 230: ... LOL RX Loss of Lock FAIL TX LOL TX Loss of Lock QSFPs OK WARN Temp WARN VCC WARN RX PWR LO WARN RX PWR HI WARN TX PWR LO WARN TX PWR HI FAIL SFP Not Ready FAIL RX LOS RX Failure FAIL TX LOS TX Failure FAIL EQ Fault EQ Failure FAIL RX LOL RX Loss of Lock FAIL TX LOL TX Loss of Lock FAIL Temp FAIL VCC FAIL RX PWR LO FAIL RX PWR HI FAIL TX BIAS LO FAIL TX BIAS HI FAIL TX PWR LO FAIL TX PWR HI SFP_N_...

Page 231: ...ltage sensor name VOLTAGE_N_VALUE Logs current voltage reading VOLTAGE_N_STATE Logs temperature sensor state Valid values are OK WARN Low Low but in tolerance WARN High High but in tolerance SFP_N_WAVELENGTH Logs transmit wavelength in nm SFP_N_X_LASER_BIAS Logs bias level in mA SFP_N_X_TX_POWER Logs transmit power level in dBm SFP_N_X_TX_POWER_STATE Logs transmit power level Valid values are OK W...

Page 232: ...GA Page The logging page comprises three columns Enable check boxes to activate log fields as required Where N is the input number Logging Page Column Description Log Enable Select the check boxes that correspond to the parameters for which log information should be collected Log Field Displays the name of the logging field Log Value Displays the current log value Parameter Description TEMP_N_NAME...

Page 233: ...P 3901 Only on page 216 An additional field is provided for you to optionally specify a name for the input output Figure 7 25 Input Spigot Logging Page Figure 7 26 Output Spigot Logging Page The logging page comprises three columns Enable check boxes to activate log fields as required Logging Page Column Description Log Enable Select the check boxes that correspond to the parameters for which log ...

Page 234: ...n the rear panel See 12G 3G HD SD SDI I O Serial digital video inputs outputs 4 on page 34 and 3G HD SD SDI I O Serial digital video inputs outputs 12 on page 35 OUTPUT_N_NAME Name of the output that you have defined OUTPUT_N_STATE Valid values are OK output signal good FAIL output signal not detected WARN Freeze WARN Pattern WARN Black OUTPUT_N_TYPE Valid values are SD SDI HD SDI HD SD 3G SDI OUT...

Page 235: ...ing device connected to the RollCall network Figure 7 27 FEC Page Enable check boxes to activate log fields as required Where N is the SFP number To identify SFP 1 2 see Rear Panel and Connectors on page 32 Log Field Description FEC_N_CORRECTED_ERRORS Number of corrected errors for FEC N FEC_N_UNCORRECTED_ERRORS Number of uncorrected errors for FEC N ...

Page 236: ...ng field Log Value Displays the current log value Parameter Description NMOS_STATUS Displays the current NMOS status Valid values are OK Off NMOS functionality is disabled OK Registered the module has been successfully added to the NMOS registry WARN Registering the module is currently being registered FAIL Unregistered the registration process has failed NMOS_REGISTRATION The current card s NMOS ...

Page 237: ...Y_PORT The current port number being used to connect to the NMOS registry for making queries NMOS_REGISTRATION_PORT The current port number being used to connect to the NMOS registry for making device registrations Parameter Description ...

Page 238: ...equired Logging Page Column Description Log Enable Select the check boxes that correspond to the parameters for which log information should be collected Log Field Displays the name of the logging field Log Value Displays the current log value Parameter Description NVRAM_FS Logs whether the installed file system is QNX6 PowerSafe or FAT32 TOTAL_AVAILABLE_MEMORY Logs total amount of CPU memory avai...

Page 239: ..._RESTORE Logs where system memory was restored from Valid values are FAT32 restored from FAT32 OK restored from QNX6 PowerSafe FAIL memory restoration failed PMIC_VERSION Logs name of the on board power management chip Parameter Description ...

Page 240: ...isabled Index This slider allows up to 32 distinct RollTrack outputs to be set up Dragging the slider selects the RollTrack Index number displayed below the slider Clicking selects the default preset value Source The source of information that triggers transmission of data is selected with this control Dragging the slider selects the RollTrack source displayed below the slider Clicking selects the...

Page 241: ...Track Output Index destination The command may be changed by typing a code into the text field and then selecting to save the selection Clicking returns to the default preset command A RollTrack command consists of two sets of numbers for example 84 156 The first number 84 is the actual RollTrack command The second number 156 is the value sent with the RollTrack command Sending A message is displa...

Page 242: ...se details by Grass Valley support if you need technical assistance Parameter Description Product Name of the card Software Version Currently installed software version number Firmware Version Currently installed firmware version number Serial No Card serial number SW Build Factory software build number This number identifies all parameters of the card OS Operating system version number Rear ID Re...

Page 243: ...ce disturbances on the output picture Restarting the card will affect all outputs Defaults Provides options to reset the card to its defaults Default Settings All settings are reset to their default values except for network configuration and IP addresses Factory Defaults All settings are reset to their default values including network configuration and IP addresses Remove Licenses Click to remove...

Page 244: ...e frame s control panel This is useful when the card is first installed in the frame to make it quickly operational See Local control using the Densité frame control panel to set the Card s IP Addresses on page 38 For a IQUCP25 The Ethernet Gb page displays details and the status of the card front Ethernet port of the IQUCP Card This is for Grass Valley engineering use only The IQUCP25 defaults to...

Page 245: ...rnet port s connection mode DHCP The Ethernet port uses automatic configuration obtained from the network s DHCP server Static You set a fixed Ethernet port configuration IP Address Default Gateway and Subnet Mask New settings are applied when Restart is clicked Restart Click when the New Mode setting is changed for this to take effect Only make this change during off hours as this can take up to ...

Page 246: ...246 MADI Processing SDC Ethernet Arcnet Ethernet Arcnet Not currently used ...

Page 247: ... RTP Payload Types Payload Selection Set 1 Set 2 Select the appropriate set of standards to be used The set contents are displayed on the Payload Format pane Payload Format Hexadecimal code used to identify payload types 2022 6 SMPTE ST 2022 6 payload type Not applicable 2110 10 SMPTE ST 2110 20 payload type Not applicable VC2 VC2 payload type VC2 is currently unsupported 2110 30 SMPTE ST 2110 30 ...

Page 248: ... SFP Configuration Page The majority of SFPs will operate correctly with UCP 3901 IQUCP25 cards without any need for adjustment Some however may need to have card parameters set a little differently If difficulties are encountered with an SFP not working as expected proceed as follows 1 Select the appropriate SFP type from the SFP Database List and click Take Verify whether the SFP is now working ...

Page 249: ...ewer head outputs 4 source spigots for mosaic IP stream outputs IP Tx 4 mosaic SDI video HD BNC copy outputs available on the rear panel See 12G 3G HD SD SDI I O Serial digital video inputs outputs 4 on page 34 and 3G HD SD SDI I O Serial digital video inputs outputs 12 on page 35 Multiviewer Input Scaling There are 12 image scaling blocks within the multiviewer This means that There is only one s...

Page 250: ...The layout and style of the Multiviewer SDC multiviewer video walls are designed with the Grass Valley Orbit software application Wall designs are stored as individual projects Grass Valley Orbit projects which are then pushed to an Multiviewer SDC device for use Multiple wall layout designs may be generated and stored on a PC Different wall designs can then be pushed to or pulled from the multivi...

Page 251: ...hould be meaningful concise and unique for each device for each multiviewer When a project is opened in Orbit the project name may be edited if required This forms a new separate Orbit project Opening an Orbit Multiviewer Project Orbit aims to keep a project up to date If there are any differences between a project open in Orbit and the same named project on a connected device then you must resolv...

Page 252: ... multiviewer video wall This procedure includes STEP 1 Preliminary Multiviewer SDC Configuration on page 253 STEP 2 UCP 3901 Media Interface s Setup Video IP Streams on page 255 STEP 3 Make a Change to the Video Wall on page 257 Assumptions It is assumed that The UCP 3901 is new and from the factory The UCP 3901 Card has been installed into the frame See UCP 3901 Card Installation and Operation on...

Page 253: ...ll templates Configuration items include Basic configuration of the media Ethernet interfaces Video reference selection RollCall settings including domain Multiviewer head display output video standard selection STEP 1 1 Preliminaries UCP 3901 Templates This sub section uses the MANAGEMENT IQ modular chassis Ethernet interface to access the UCP 3901 Card s RollCall templates 1 Open the UCP 3901 te...

Page 254: ...tion template see Time Sync Configuration on page 85 configure the PTP Network Interface to use and the PTP Configuration items including PTP Domain PTP Delay Request Frequency and PTP Multicast IP address 5 Click Restart and wait for the module to reboot approximately 75 seconds Wait for the module to restart and the SFP 1 and SFP 2 rear Ethernet interfaces are now ready to be used in a target sy...

Page 255: ...restarts for all the settings changes to take effect Wait for the module to complete its restart approximately 75 seconds STEP 2 UCP 3901 Media Interface s Setup Video IP Streams After the rear SFP 1 and SFP 2 Ethernet interfaces are set up in STEP 1 Preliminary Multiviewer SDC Configuration on page 253 the various spigots of the UCP 3901 need configuring for Sending Spigots 1 to 4 These are the s...

Page 256: ...tes see Spigot 1 to 4 Multiviewer Head Outputs on page 292 configure the following settings for both the primary and secondary flows For video flows set the Flow Type to 2110 20 For audio flows set the Flow Type to 2110 30 For all Flows configure the following settings Multicast IP address Multicast IP port Source IP address Source IP port Flow type For each parameter set the value in the New colu...

Page 257: ... video wall See Quick Edit of Project on page 260 Push the amended project back to the unit and see the change See Push a Project from Orbit to a Device on page 263 Pull a project from the Multiviewer SDC See Pull a Project into Orbit from a Device on page 265 Assumptions This sub section assumes that The UCP 3901 is connected to a media network and receiving sending video IP streams IP addresses ...

Page 258: ...owse to a new empty folder and click Choose Fig 8 5 New Project Dialog Connected Multiviewer Project 4 Click Next All accessible multiviewer devices are listed If the multicast auto discovery that populates this list does not work you can specify a host and do unicast discovery default domain 100 Fig 8 6 New Project Dialog Multiviewer List ...

Page 259: ... the new list and click OK Fig 8 7 New Project Dialog Multiviewer List Orbit connects to the device and pulls the Orbit multiviewer list from the device 9 At the login dialog enter the appropriate project Username and Password Note For the default project on a factory device this is admin and admin Fig 8 8 Login Dialog 10 Click Login A new Orbit project has been created from a connected multiviewe...

Page 260: ...reviously specified folder 11 Click File Save Project in the main menu or click the Save Project icon in the main tool bar Quick Edit of Project To make a visible change to the project 1 Click the large Walls icon and select a wall item in the list for example Output 1 The selected wall is opened in a Wall Editor Fig 8 10 Project Open in Orbit ...

Page 261: ...261 UCP 3901 User Manual Fig 8 11 Wall Editor 2 Double click on the Text Label Tile The tile is opened in the Tile Editor Fig 8 12 Tile Editor To make a change the tile Text Label Tile ...

Page 262: ...round Color property 5 Click on the icon to show the Background Color dialog See Figure 8 13 on page 262 6 Select a color and click OK Fig 8 13 Color Picked 7 Click the Save File icon in the main tool bar to save the tile change Fig 8 14 Tile with New Background Color 8 Click on the x on the tile tab to close the tile Alpha 255 entered fully opaque ...

Page 263: ... Changed Wall 1 Push a Project from Orbit to a Device To push a project from Orbit onto a multiviewer 1 Open a project in Orbit and click Multiviewer Properties 2 If the multiviewer details require changing enter the target device s IP address RollCall network number and unit number and Domain ID 3 Click OK ...

Page 264: ...nu 5 Select the project in the Choose Projects dialog see Figure 8 17 and click OK The project is pushed to the device Fig 8 17 Choose Projects Dialog If the device already has a project of the same name then a dialog is shown see Figure 8 18a Click Yes to overwrite with the project from Orbit When the push is complete a pushed successfully message is shown See Figure 8 18b Pull icon Push icon Sel...

Page 265: ...ject into Orbit from a device 1 Open a multiviewer project in Orbit and click Multiviewer Properties 2 If the multiviewer details require changing enter the target device s IP address RollCall network number and unit number and Domain ID Click OK 3 Click the Pull icon in the main menu 4 Select the project in the Choose Projects dialog see Figure 8 19 and click OK The project is pulled from the dev...

Page 266: ...9 Choose Projects Dialog 5 When the pull is complete a pulled successfully message is shown See Figure 8 20 Fig 8 20 Pull Message The Orbit project of the same name in as the one pulled from the device has now been updated It is now the same as that on the device Select the project to pull ...

Page 267: ...gn on a multiviewer device may be changed through the use of Orbit walls layouts and themes Procedure The procedure for video wall design and deployment is similar to the procedure for Grass Valley s MV 8 Series of multiviewers MV 800 etc A basic video wall is described in the Orbit documentation and includes For further Orbit instruction and details on using Orbit for multiviewer wall layouts see...

Page 268: ...ifying Multiviewer TSL Tally Mode on page 268 Specify index parameters for each UMD on the video wall See Specifying Index Parameters for each UMD on page 269 Specifying Multiviewer TSL Tally Mode The multiviewer may get its TSL Tally information in one of two modes Server Mode Multiviewer SDC listens for Tally messages Specify the Multiviewer SDC IP address and network port to receive Tally messa...

Page 269: ...by each UMD are specifiable in the UMD properties Values can be set manually or values can be automatically assigned as part of assigning inputs to video tiles Refer to Orbit documentation UMD Properties TSL Protocol Version 3 1 TSL Protocol 3 1 is the original TSL protocol for sending data over a serial comms connection or through Ethernet The multiviewer supports an Ethernet connection Each mult...

Page 270: ...wer monitor screen is addressed by a Screen Index and each UMD within it by a Display Index Each UMD associated with a video tile must have two parameters set up 5 0 Screen Index Index number address of each display monitor 16 bit FFFF reserved 0 not used 5 0 Display Index Index number for each UMD in a display 16 bit FFFF reserved 0 based 1 Select Video Tile and Video Tile Properties are shown 2 ...

Page 271: ...271 UCP 3901 User Manual Fig 8 23 Orbit Video Tile UMD TSL 5 0 Properties UMD enabled TSL 5 0 properties Selected Video Tile Multiviewer Input 3 ...

Page 272: ...g 8 24 Monitor Display Screen Multiviewer SDC head display output Clock Widget UMD Widget Display screen Video Widget Audio Bars Widget Video Tiles Tile Grid for display output Logo image Head display output UCP 3901 IQUCP25 IQUCP50IQUCP Card with Multiviewer SDC Custom Tile UMD Widget ...

Page 273: ...ple a tile may display a video picture with audio level and other related status information Other information may be displayed in tiles for example time images labels and or text Tile Grid A multiviewer video wall screen is divided up into rectangular areas various sizes and arrangements are possible A tile grid can be used in Orbit for quick positioning of tile arrangements on a wall Fine Grid A...

Page 274: ...ing an error correcting code The redundancy allows the receiver to detect and correct errors Flow Another term for an elementary IP stream usually a sequence of real time data sent as an RTP IP data stream For example TR 03 describes how a media stream e g an original SDI stream may be sent as three flows Video Audio and Ancillary essence data IEEE 1588 A Precision Time Protocol PTP to synchronize...

Page 275: ...bit rate media Multicast Stream A one to many IP stream Devices receiving the stream subscribe to the multicast stream s IP address Network A group of two or more Ethernet enabled systems linked together through IP In the case of broadcast video IP network a local area network optimized for the transfer and broadcast of real time high bandwidth video IP streams Out of Band Control Method of sendin...

Page 276: ... each network A receiving device can switch between two received streams and recover the content of the original full stream SMPTE 2110 A standard for an extensible RTP IP streams essence streams including uncompressed video referenced to a common clock Includes support for a variable raster size up to 32Kx32K pixels HDR and a variety of color sampling schemes bit depths and frame rates Source Ori...

Page 277: ... UHD through quad link quadrants or signal interleaved as 2SI Multiviewer Head Display Outputs 4 head display outputs SDI HD BNC copies QSFP cages for video IP streams Standards supported SMPTE 2110 Resolution 1080p 4K UHD support with four outputs used together as quad link Reference Timing Using IEEE 1588v2 PTP compliant with SMPTE 2059 2 Multiviewer Video Walls Drag and Drop objects onto the sc...

Page 278: ...TPG Test Pattern Generator on page 286 Counters on page 287 FEC on page 288 NMOS on page 288 Ethernet Pages 1 and 2 on page 288 Ethernet 1 and 2 RTP Sender on page 289 Ethernet 1 and 2 RTP Receiver on page 289 Ethernet RTP Receiver Video Stats on page 289 Ethernet RTP Receiver Audio Stats on page 289 Ethernet RTP Receiver Meta Stats on page 289 Link Control on page 290 Destination Timing on page 2...

Page 279: ...oopback Router on page 294 Setup on page 295 Ethernet Gb on page 295 Interop on page 295 Interop on page 295 SFP Configuration on page 296 HDR Control on page 296 For Multiviewer SDC templates see RollCall Templates Multiviewer SDC Configuration on IP port 2051 on page 297 ...

Page 280: ...rmation to Display Select the inputs to display data for from the Video Selection drop down list Select Video Input Status Video Output Status Network Status or Spigot Link Status from the Information Select pane as required The selected information type is displayed on the Information display pane Note Video inputs are considered to be video signals from the Multiviewer SDC Thus SDI 1 to SDI 4 vi...

Page 281: ...281 UCP 3901 Multiviewer SDC Chapter User Manual Configuration The Configuration page allows basic card parameters to be set Fig 9 2 Configuration page ...

Page 282: ...e Software Version below for information on how to change this Where Am I Causes the front edge and rear panel LEDs to flash allowing the card to be easily identified Genlock Select Genlock type Network use the network s PTP clock See Time Sync Configuration on page 284 for further configuration settings External Reference use the reference signal found at the REF connector on the card s rear pane...

Page 283: ...rsion is not normally required for Multiviewer SDC Note Restore and Restart buttons are displayed only when an item not currently installed is selected Click Restart to restart the card and implement any changes made See Upgrading the UCP 3901 IQUCP25 IQUCP50 s SDC Application on page 309 for how to change the SDC application Installed 25G 50G Licensed Options Shows the currently installed license...

Page 284: ...rce signal to be used for synchronizing IP flows through the Multiviewer SDC and the configuration of any properties associated with the relevant source To use PTP first set Genlock to Network See Configuration on page 281 The configuration of this page is the same as for Essence Processing See Time Sync Configuration on page 85 ...

Page 285: ...to use to configure the Multiviewer SDC 1G Rear panel MANAGEMENT Ethernet interface This option is not to be used for IQUCP25 IQUCP50 cards Ethernet 1 Rear panel SFP1 Ethernet interface Ethernet 2 Rear panel SFP2 Ethernet interface The Multiviewer SDC interface uses port 2051 See Rear Panel and Connectors on page 32 See also Connecting to the Multiviewer SDC with RollCall for UCP 3901 Card on page...

Page 286: ...PG Select the video standard of the moving color bars test pattern to apply to the spigot from the drop down list Select None to turn off the test pattern Note Different video standards may be selected for the test pattern if required But for normal operation the multiviewer head display outputs from the Multiviewer SDC support high resolution video standards Refer to Multiviewer SDC IP Video Inpu...

Page 287: ...wer SDC multiviewer head display output video signals that is from the Multiviewer SDC to the UCP 3901 Card Clear All RTP Counts Counts jumps in an Real time Transport Protocol RTP packet ID sequence in an IP flow This indicates any lost dropped or out of sequence RTP packets These counters are found on RTP Receiver and Ethernet pages Clear All MAC Error Counts Counts packets marked as bad for exa...

Page 288: ...P1 and Ethernet 2 is identified as SFP2 on the card s rear panel See Rear Panel and Connectors on page 32 The Ethernet pages show details and status for each of the Multiviewer s high speed media network interfaces The UCP 3901 defaults to use DHCP for Ethernet port address negotiation but this can be overridden and a static IP address can be specified if required The Ethernet configuration for th...

Page 289: ...ideo Stats page displays information on the reception of video IP flows on network interfaces 1 and 2 on a spigot by spigot basis The Multiviewer SDC receives video IP data packets on spigots 5 to 16 The configuration of this page is the same as for Essence Processing See Ethernet RTP Receiver Video Stats on page 107 Ethernet RTP Receiver Audio Stats The Ethernet RTP Receiver Audio Stats page disp...

Page 290: ...als See Spigot 1 to 4 Multiviewer Head Outputs on page 292 and Spigot 5 to 16 Multiviewer Inputs on page 292 On the rear panel see 3G HD SD SDI I O Serial digital video inputs outputs 12 on page 35 to know on which HD BNC input output each spigot is available Enable Enable the spigots to be used for UHD Quad Links as required Note that these controls are not available when using 12G TPG SDQS Set t...

Page 291: ...able is set the audio will fade down on input loss and perform an audio V fade down then up during input switching For the Multiviewer SDC spigots 5 to 16 are configured as destination spigots as they receive audio IP streams The configuration of this page is the same as for Essence Processing See Audio V Fade on page 119 TPG UHD ST352 Insertion Set the ST352 ancillary data type according to how t...

Page 292: ...l digital video inputs outputs 4 on page 34 and 3G HD SD SDI I O Serial digital video inputs outputs 12 on page 35 to know on which HD BNC input output each spigot is available Spigot 1 to 4 Multiviewer Head Outputs The Spigot pages 1 to 4 configure the multiviewer s head output mosaic streams The configuration of these pages are the same as for Essence Processing though only audio and video essen...

Page 293: ... types The configuration of this page is the same as for Essence Processing See Logging System on page 140 Logging Network The Logging Network page shows MEDIA network message types The configuration of this page is the same as for Essence Processing See Logging Network on page 145 Logging Network 1G UCP 3901 Only The Logging Network page shows MANAGEMENT network message types The configuration of...

Page 294: ... to view log fields of the Multiviewer SDC and select those log fields to be enabled The configuration of this page is the same as for Essence Processing See Logging Card Diagnostics on page 158 RollTrack The RollTrack page sets up RollTrack settings for the UCP 3901 Card allowing information action events to be triggered by the state of multiviewer head display outputs on spigots 1 to 4 The confi...

Page 295: ...pgrade as well as NMOS IS 04 and IS 05 communications with the NMOS registry The Ethernet configuration for this port can also be set through the frame s control panel This is useful when the card is first installed in the frame to make it quickly operational See Local control using the Densité frame control panel to set the Card s IP Addresses on page 38 For a IQUCP25 IQUCP50 The Ethernet Gb page...

Page 296: ... Multiviewer SDC without any need for adjustment Some SFP transceiver modules however may need to have some SFP parameters adjusted The configuration of this page is the same as for Essence Processing See SFP Configuration on page 170 HDR Control The HDR Control page allows multiviewer input HDR essences to be configured spigots 5 to 16 The configuration of this page is the same as for Essence Pro...

Page 297: ...nfiguration is typically performed once after Multiviewer SDC installation RollCall Control Panel may be used to configure and control various Multiviewer SDC items including selection of video wall layouts monitoring alarm status acknowledging alarms and control of timer widgets on the video wall RollCall templates for the Multiviewer SDC This section describes the RollCall templates for the Mult...

Page 298: ...ltiviewer SDC system status at the top of each template page OK the Multiviewer SDC multiviewer is working correctly Fail the Multiviewer SDC multiviewer has a problem Restart Required the Multiviewer SDC application requires a restart This is required after making changes in the template for certain configuration changes to take effect ...

Page 299: ...ltiviewer RollCall settings Multiviewer monitor output format Multiviewer name Fig 9 8 System Setup Template Note The Multiviewer SDC multiviewer must be System Reset for any saved setting changes on this template page to take effect See Carrying Out a System Reset on page 301 This should only be done during off hours when the system is not in use Booting takes about 75 seconds to complete during ...

Page 300: ...nit number must be unique for each Multiviewer being configured The initial default value is 01 See About the RollCall Address on page 301 for more information RollCall Port This parameter is not used RollCall IP Port This parameter is not used Domain ID Enter RollCall domain ID See About the RollCall Domain ID on page 301 for more information Output Format The Output Format of multiviewer head di...

Page 301: ...ltiviewer here Up to 64 characters can be displayed in the notes field Click or press return to save the name locally Parameter Description Note RollCall address This is not an IP network address A RollCall address has the form NNNN UU PP where NNNN is the RollCall network number UU is the RollCall unit number PP is the multiviewer input number 01 02 and so on Note RollCall Domain ID RollCall uses...

Page 302: ...iewer project Each video wall in an Orbit multiviewer project has a Name property which is set to Wall 1 Wall 2 and so on You can edit the wall name in GV Orbit Each wall layout in an GV Orbit multiviewer project has a Name property which is set to Layout1 Layout2 and so on You cannot edit this The wall layout to be used for each wall can be selected in the respective drop down box of the Layout t...

Page 303: ... type of on screen transition seen when changing between wall layouts Select for fade down to black then fade up to new layout Deselect for a cut from current to new wall layout Wall Designer Mode Overlay Information Not supported Identify Inputs Not supported Identify Outputs Not supported Table 9 1 Layout and Controls Settings continued Setting Description ...

Page 304: ... separately set up IP address and network port information Table 9 2 TSL Mode Settings Setting Description UDP 3 1 Port Enter the IP port to receive TSL 3 1 messages on 5 0 Port Enter the IP port to receive TSL 5 0 messages on Mode Select Server or Disabled TCP IP Address For Server Mode Enter the local IP address of the Multiviewer SDC to be used for TSL messages For Client Mode Enter the IP addr...

Page 305: ...r SDC Chapter User Manual Enter information as required then click to save 5 0 Port Enter IP port to receive TSL 5 0 messages on Mode Select Server Client or Disabled Table 9 2 TSL Mode Settings continued Setting Description ...

Page 306: ...le 9 3 Timer Control Settings Setting Description Running Start stop the timer Set to start the timer De select to stop the timer Reset Select to reset the timer Target time Enter the timer s target time When the target time is changed the timer is reset Target time format HH MM SS For example 12 30 00 Count Up Count Down Select to reset the timer and count up down Note On the multiviewer video wa...

Page 307: ...otocol Template Enter information as required then click to save Table 9 4 RollCall Timer Request Protocol Settings Setting Description IP Address Set the IP Address of an eTimer server device then press Port Set the associated port number to use for Timer Request Protocol messages Enabled Select to enable use of Timer Request Protocol messages Note Configuring an eTimer An Orbit Timer widget can ...

Page 308: ...308 Multiviewer SDC Timer Request Protocol ...

Page 309: ...cessary and quickly restore the configuration Save and restore are found by right clicking the unit name in the Network Browser Fig 10 1 UCP 3901 Menu For more information about how to use save and restore see the RollCall Control Panel User Manual available for download from the Grass Valley website See Related Documentation on page 19 Upgrading the UCP 3901 IQUCP25 IQUCP50 s SDC Application The ...

Page 310: ...chanic Operator s Manual See Related Documentation on page 19 A SDC Application upgrade is done in the following stages in RollCall Stage 1 To add import the upgrade package to RollCall Control Panel on page 310 Stage 2 To install the upgrade on the UCP 3901 IQUCP25 IQUCP50 on page 311 Stage 3 To delete RollCall s cache for the UCP 3901 IQUCP25 IQUCP50 on page 313 To add import the upgrade package...

Page 311: ...dded to the list of available upgrades and units may be upgraded accordingly See To install the upgrade on the UCP 3901 IQUCP25 IQUCP50 on page 311 To install the upgrade on the UCP 3901 IQUCP25 IQUCP50 A unit can only be upgraded if an appropriate upgrade package is available See To add import the upgrade package to RollCall Control Panel on page 310 1 Right click on the unit name in the Network ...

Page 312: ...ed that the Upgrade Changed Files Only setting is used to ensure a fast upgrade However some units may ignore this setting and always upgrade all files Post Upgrade After completion of the upgrade this panel displays the new unit name unit type unit ID unit version and loader version Software Releases This drop down list shows all of the software releases available for the unit type Note that befo...

Page 313: ...n the list of software releases If not a dialog displays prompting to save the unit s current software release before upgrading At the end of the upgrade if the unit does not come back online a dialog displays Further attempts are made to establish contact with the unit until it either comes back online or the Cancel button is pressed Cancelling this operation has no effect on the success or other...

Page 314: ...upon purchasing a license from Grass Valley They are small zip files Store the zip files in a network location that can be accessed by the Control Panel To obtain a license contact Grass Valley Technical Support See Grass Valley Technical Support on page 338 The process of installing a license to an UCP 3901 IQUCP25 IQUCP50 follows the standard process for a hardware card with licenses administere...

Page 315: ... on the UCP 3901 IQUCP25 IQUCP50 on page 315 To install the License on the UCP 3901 IQUCP25 IQUCP50 1 Right click on the unit and click on Unit License to open the Unit License dialog Fig 10 9 UCP 3901 Menu The Unit License dialog displays the currently installed licenses for both 3G and Licensed Options as well as any available licenses in the licensing database 2 Select the licenses to install a...

Page 316: ...ftware Version on the UCP 3901 IQUCP25 IQUCP50 The UCP 3901 Card is a generic card and its functionality is set by the licensing that has been enabled on it and by selecting a software version A UCP 3901 Card may have more than one license and software version for example Essence Processing and another application The required functionality is selected by selecting the corresponding licensed softw...

Page 317: ...tions and panes can be seen The Card Firmware pane displays the firmware option currently loaded Other available firmware versions are displayed in the New pane The Software Version pane displays details of the currently loaded SDC license Alternative SDCs available for loading are displayed in the New pane The Installed 25G 50G Licensed Options panes show all installed licenses See Configuration ...

Page 318: ...eturn to the current software version in effect 2 Click Restart The module will reboot and start with the new SDC functionality Booting takes about 75 seconds to complete 3 Select any required options from the Card Firmware New pane if available Click Restart once more if any options are selected 4 In the Configuration template check that the current software version shows as Licensed OK The modul...

Page 319: ... Each card has connectors which plug into a mid frame mother board for distribution of power and for connection to the controller card and a second connector which plugs directly into the rear panel to support rear panel connections Model Description Grass Valley Part Number See UCP 3901 Card IQUCP25 IQUCP50 Cooling fan UCP 3901 FAN Cooling Fan Operational Assessment on page 320 Micro SD Card 93 0...

Page 320: ...t the fan makes a distinctive sound and it rotates at a slower speed thereby reducing airflow which undermines its ability to remove heat from the UCP 3901 Under this condition fan replacement is required Also dust contained in the ambient air can accumulate on the fan and on surfaces around the fan and heatsink thereby reducing airflow and preventing air from coming into direct contact with the h...

Page 321: ...n page 153 then undertake the following diagnostic steps in the following order 1 Confirm that the room temperature is within UCP 3901 s operating temperature range specification If necessary take corrective actions by for example increasing the amount of air conditioning made available to the Densité frame 2 Confirm that air flow around the Densité frame is not obstructed If necessary take correc...

Page 322: ... the fan is worn out and it must be replaced with a new one Replacing the UCP 3901 s Fan Fan Replacement Kit The replacement fan kit is available by contacting Technical Support See Grass Valley Technical Support on page 338 Required Tools The following field supplied material is required Compressed air to remove dust from the UCP 3901 Needle nose pliers to separate push pins from the PCB Curved t...

Page 323: ...he two pushpins so that they unlatch Push the pin through the card to release it from the assembly 4 Flip the card back to the component fan side Insert the pliers under the one of the pushpin heads Press down on the center of the fan assembly to prevent it from flipping on its side and gently pry the pin from the heatsink assembly Repeat for the second pushpin 5 Using curved tweezers disconnect t...

Page 324: ... this ensure that The Fan Status Check alarm is inactive See Logging System on page 140 for more information If the Fan Status Check alarm is active ensure the fan is plugged into Power Connector J14 The critical temperature alarm is inactive See TEMP_N_STATE in Logging FPGA on page 153 for more information Replacing the Micro SD Card When the UCP 3901 does not boot the Micro SD card must be repla...

Page 325: ...the micro SD card socket 5 Insert the UCP 3901 card into the Densité frame Troubleshooting Following a methodical process of elimination try the following steps 1 Are you using the latest UCP 3901 IQUCP25 IQUCP50 firmware To upgrade an UCP 3901 IQUCP25 IQUCP50 s firmware see Upgrading the UCP 3901 IQUCP25 IQUCP50 s SDC Application on page 309 2 The Status Indicators on the UCP 3901 IQUCP25 IQUCP50...

Page 326: ... seated in the SFP cartridge Make sure the media network switch is a powered up Make sure the total loss in the optical path is not greater than 2 5 dB due to any combination of factors mentioned here Measure the loss if necessary Check the fiber for any damage The fiber cannot have small circumference loops Check the fiber connectors for dirt and debris See Keep Fiber Connections Clean on page 32...

Page 327: ...ream for all input and output spigots Keep Fiber Connections Clean Safety First Never assume a fiber is dark Never look directly into the end of a fiber cable All people in the area must wear laser safety glasses with side shields After the card has had its firmware upgraded the menus for UCP 3901 in RollCall are empty or configuration information is missing or incoherent See To delete RollCall s ...

Page 328: ...r ends to verify cleanliness Grass Valley strongly urges you to select a cleaning method that meets your needs and to use it rigorously and consistently A few tips When an optical fiber is disconnected from the SFP module s optical port always Insert a dust plug into the empty SFP module s optical port Install caps on the open end of the fiber optic cable This keeps airborne particles from settlin...

Page 329: ...or ST425 5 3G SDI to SMPTE 424M 425M level A compatible HD SDI to SMPTE292M 274M 296M SD SDI to SMPTE259M C Input cable length UCP 3901 Belden 4794A UHD 12G 60m Belden 1694A 2HD 3G 120m Belden 1694A HD 1 5G 165m Belden 1694A SD 270M 400m Input cable length IQUCP25 IQUCP50 Belden 1694A 3 Gbit s 80m Belden 1694A 1 5 Gbit s 140m Belden 1694A 270 Mbit s 350m Return loss UCP 3901 15 dB up to 1 5 GHz 10...

Page 330: ... Electrical Transport Stream Connector Format HD BNC 75Ω panel jack on standard connector panel Conforms to AES10 2008 Input cable length UCP 3901 Belden 4794A UHD 12G 60m Belden 1694A 2HD 3G 120m Belden 1694A HD 1 5G 165m Belden 1694A SD 270M 400m Input cable length IQUCP25 IQUCP50 Belden 1694A 3 Gbit s 80m Belden 1694A 1 5 Gbit s 140m Belden 1694A 270 Mbit s 350m Return loss UCP 3901 15 dB up to...

Page 331: ...ST296 525i59 94 625i50 Number of supported streams See Supported Multiviewer Media Network Input Capacity on page 26 Conforms to 2022 6 7 2110 20 30 40 Scalers One per multiviewer input Video Standards 1080p50 59 94 60 UHD 1 Quad link 1080p50 59 94 60 Number of heads 4 Conforms to 2022 6 7 2110 20 30 Video Standards 1080p50 59 94 60 UHD 1 Quad link 1080p50 59 94 60 Electrical Transport Stream Conn...

Page 332: ...2 3 25 Gigabit Ethernet over twinaxial cablesa ST2110 10 20 30 SMPTE 291M IETF RTP Payload for Ancillary Data VC 2 AES67 IEEE 1588v2 SMPTE 2059 2 a Note that when using a 50Gbps breakout cable ensure that the network switch supports this feature FEC The UCP 3901 supports clause 74 Base R and clause 108 RS FEC Ensure the network switch you plan to use supports FEC error correction that you are plan...

Page 333: ...hysical 4 SFP28 Ethernet cartridge slots UCP 3901 25Gb SFP 2 x 25GbE UCP 3901 50Gb 2 x 50GbE QSFP or 1 x QSFP with two lanes of 50GbE Addressing DHCP default or static Connector Format See Supported SFP28 Cartridges for IQUCP25 IQUCP50 on page 26 Conforms to IEEE 802 3by 25 Gigabit Ethernet over fiber IEEE 802 3 25 Gigabit Ethernet over twinaxial cablesa ST2110 10 20 30 SMPTE 291M IETF RTP Payload...

Page 334: ...etwork switch supports this feature Status Input and Output status User memories None RollCall RollCall Through the gateway or directly through the rear SFP RollTrack controls On off Index Source Address Command Status Sending Card edge indicators See Front Card edge Interface on page 27 for more information Power Consumption UCP 3901 55 Watts IQUCP25 31 PR IQUCP50 45 5 PR ...

Page 335: ...ass 1 laser which emits invisible radiation whenever the module is powered up Because the SFP is hot swappable the module may be powered up as soon as it is installed DO NOT LOOK INTO AN OPERATING SFP FIBER MODULE S CONNECTORS AS EYE DAMAGE MAY RESULT The SFP module is sensitive to electrostatic discharge ESD It is recommendedthatyou useanESD preventivewriststrap groundedto the GV Node chassis whi...

Page 336: ...clean Carefully remove any debris if necessary 3 Plug the LC terminated fiber optic cable into the SFP module Removing the fiber optic cables 1 Grasp the LC fiber optic connector that is plugged into the SFP module and pull it straight out to disengage the optical fiber from the SFP Never pull the fiber optic cable itself as irreversible damage may occur 2 Insert a dust plug into the SFP module 3 ...

Page 337: ... it straight out of the slot Do NOT pull on the bale clasp lever to remove the module as it is easily damaged You may find that you need to wiggle the module or perhaps push it into the slot a bit before it will release and slide out 3 For fiber optic models insert a dust plug into the SFP module Bale Clasp ...

Page 338: ...port www grassvalley com support Customers with a support contract should call their personalized number which can be found in their contract and be ready to provide their contract number and details Corporate Head Office Grass Valley 3499 Douglas B Floreani St Laurent Quebec H4S 2C6 Canada Telephone 1 514 333 1772 Fax 1 514 333 9828 www grassvalley com ...

Reviews: