Test Modes and Troubleshooting
♦
C6 - 16
Error Messages and Their Causes
Error Messages with their Possible Causes and Probable Solution.
OVER CURRENT
POWER OFF THEN ON
•
•
The beeper sounds
SPEED ALARM
POWER OFF THEN ON
•
•
The beeper sounds
Cause
Solution
Excessive load is causing
the current to the motor to
exceed the rated value
•
Cutting conditions do
not suit the cutting
media
⇒
Lower the cutting
SPEED and/or the
cutting FORCE
•
Movement of the pen
carriage is being
obstructed
⇒
Turn off the plotter,
remove the obstacle,
then turn the plotter
back on.
•
The pen carriage was
subjected to external
pressure during cutting
⇒
Turn off the plotter,
remove the obstacle,
then turn the plotter
back on.
•
Media scraps stuck in
moving parts and
impeding plotter
operation
⇒
Turn off the plotter,
remove the media
scraps, then turn the
plotter back on
•
Abnormal acceleration
rate table
∗
If error occurs
frequently, contact your
sales representative or
nearest Graphtec
dealer.
Cause
Solution
•
Immediately after
turning on the plotter,
excessive force was
used to manually move
the pen carriage
⇒
Turn the plotter off then
back on again
•
Internal speed control is
faulty
⇒
Turn the plotter off then
back on again
∗
If error occurs
frequently, contact your
sales representative or
nearest Graphtec
dealer.
Summary of Contents for Cutting Pro FC4100-100
Page 1: ...cutting pro FC4100 series series USER S MANUAL 1 a...
Page 138: ...Setting the Interface Functions C7 7 Input Output Circuitry Input Output Timing Chart...
Page 147: ...Specifications C8 6 FC4100 100 without Stand FC4100 100 with Stand Standard and Basket Option...
Page 148: ...Specifications C8 7 FC4100 130 without Stand FC4100 130 with Stand Standard and Basket Option...