ISTRUZIONI PER L’UTENTE
INSTRUCTIONS FOR THE USER
ANLEITUNGEN FÜR DEN BENUTZER
NOTICE POUR L'USAGER
INSTRUCCIONES PARA EL USUARIO
Combination ovens with direct and boiler system, gas and electric models. Programmable panel
54
Message
T.OUT BOIL. FILL. (it’s flashing on the display)
Diagnosis
Too much time to load the water into the boiler.
Defect
The steam generation is not working.
User behaviour
You can keep on using the oven only with convection mode
Call the technical Service.
Remarks for the
technical Service
Check the functioning of the water loading system, check the filter of the solenoid valve for water inlet and eventually that one
installed upstream are not obstructed.
Check the discharge valve for the boiler is not leaking.
Check the regular functioning of water level probes.
Message
NO WATER (it’s flashing on the display)
Diagnosis
Insufficient water pressure in the water main.
Defect
The steam generation is not working.
User behaviour
Check the on-off valve situated upstream is open
If the flashing message does not disappear , call the technical service.
Remarks for the
technical service
Check the functioning of the boiler pressure switch, eventually replace it
Message
CORRUPTED DATA (fixed on the display)
Diagnosis
Parameters of the electronic card are wrong
Defect
All cooking modes do not work correctly.
User behaviour
Call the technical service.
Remarks for the
technical service
Reset the system.
Message
BOILER DESCAIL. (it’s flashing on the display)
Diagnosis
Select as soon as possible the program n°97 to descail the boiler.
Defect
/
User behaviour
Select as soon as possible the program n°97 to descail the boiler.
Remarks for
technical service
/
Message
POWER FAIL (it’s flashing on the display for 15 seconds with buzzer in operation)
Diagnosis
Power fail
Defect
/
User behaviour
The oven will continue the cycle exactly where it stopped.
Remarks for
technical service
/