OMNI-408A Installation and Setup Guide
9–30
QUESTION 28
TRIGGERS 1 & 2
DEFAULT = 0A00
The control panel contains 2 voltage level output triggers. Triggers 1 and 2 are selected in
this question. To select a trigger type, enter in either L1 and L2 or L3 and L4, the 2 digits
representing the desired trigger type for each output trigger. Certain triggers can be selected
as Noninverting or Inverting (see description below). Consult the table below to determine
the trigger types available.
Question 28, L1 & L2 - Define Trigger #1
Default = 0A
Question 28, L3 & L4 - Define Trigger #2
Default = 03
NOTE: If the trigger is unused, enter “00”.
Digits
NON-
INVERT
INVERT
TRIGGER TYPE
DEFINITION
DESCRIPTION OF OPERATION
00
N/A
Smoke Power (Trigger
#1 Only)
Used in fire verification to reset smoke power
01
N/A
Smoke Power - No
Verification
Used to power smoke detectors with no
verification
02
22
Two-Way Voice
See below
03
23
Burglary Bell on
Follows burglary bell timer
04
24
Ready
Follows READY LED; used for keyswitch
05
25
Armed
Follows ARM LED; used for keyswitch
06
26
Exit Time
On during exit time
07
27
Entry Time
On during entry time
08
28
Fire-Only Latch
On w/fire bell, off w/code
09
29
Burglary-Only Latch
On w/burglary bell, off w/code
0A
2A
Strobe (see note below)
On steady w/burglary bell, pulse w/fire bell
0B
2B
Panic Alarm
Follows keypad panic
0C
2C
Shock Asterisk Reset
Asterisk “*” activates for 2-6 seconds
0D
2D
Duress
Pulses for 2-6 seconds following entry of
Duress code
0E
2E
RF Trouble
Active if any RF zone is in supervision or low
battery, or the bell is in supervision
0F
N/A
RF Button Toggle
Any keyfob button can toggle this trigger;
intended for lighting control
10
30
Alarm/Restore
Active on any zone alarm. Inactive on alarm
restore
11
31
Chime
Active when a zone programmed with chime
activates
12
32
Keypad Sounder
Active when keypad sounder activates
13
33
RF Momentary
Active when keyfob momentary Trigger 1 or
2 activates
NOTE: The trigger selection for "strobe" follows the same timing as selected in the bell
test option (chirp/non-chirp) (question 08, location L1). This is in addition to its normal
operation of a latched output on alarm that is reset after the system is disarmed.
Summary of Contents for Omni-408A
Page 14: ...OMNI 408A Installation and Setup Guide 2 6 ...
Page 22: ...OMNI 408A Installation and Setup Guide 5 4 ...
Page 28: ...OMNI 408A Installation and Setup Guide 6 6 ...
Page 34: ...OMNI 408A Installation and Setup Guide 8 4 ...