OMNI-408A Installation and Setup Guide
9–16
Question 08, L2
Instant Led Pulse, Open/Close Users 4/12, Temporal Bell
Default = 0
Digit
INSTANT LED
PULSE
O/C USERS 4 / 12
TEMPORAL
BELL
0
None
1
9
2
9
3
9
9
8
9
9
9
9
A
9
9
B
9
9
9
INSTANT LED PULSE - Choosing this option causes the Instant LED to reflect the CS
monitoring status. When selected, by either the installer or a download, a pulsing Instant
LED indicates to the user that the CS is not monitoring their account.
All dialer functions are maintained, regardless of whether the Instant LED Pulse option is selected
or not.
O/C USERS 4/12 - If this option is selected (along with other open and close codes
programmed), only keypad (User code 4) and keyfob 4 (User code 12) can report open and
close signals. No other keypad or keyfob will report to the CS.
TEMPORAL BELL - If this option is selected, the fire bell becomes temporal: 500mS
on/500mS off/500mS on/500mS off/1 second off. The temporal output option is available for
fire conditions. If not selected, the fire bell output will be pulse.
Summary of Contents for Omni-408A
Page 14: ...OMNI 408A Installation and Setup Guide 2 6 ...
Page 22: ...OMNI 408A Installation and Setup Guide 5 4 ...
Page 28: ...OMNI 408A Installation and Setup Guide 6 6 ...
Page 34: ...OMNI 408A Installation and Setup Guide 8 4 ...
Page 76: ...OMNI 408A Installation and Setup Guide 12 2 ...
Page 86: ...OMNI 408A Installation and Setup Guide B 4 ...
Page 88: ...OMNI 408A Installation and Setup Guide C 2 ...
Page 90: ...OMNI 408A Installation and Setup Guide D 2 ...
Page 92: ...OMNI 408A Installation and Setup Guide E 2 ...
Page 95: ......