![background image](http://html1.mh-extra.com/html/fbii/omni-408a/omni-408a_installation-and-setup-gude_547064025.webp)
Section 6 - System Operations
6–3
Quick Bypass
Quick Bypass is a programmable option (see question 05, location 3 of the programming
sequence) and allows the user to bypass zones without using a user code.
Press the [Bypass] key followed by a number from 1 to 8, which represents the zone to be
bypassed.
Example: To bypass zone 2, enter:
[Bypass] [2]
Exit Bypass
Exit Bypass is a programmable option (see question 26, location 4 of the programming
sequence) and if set, any delay zone or interior that is violated at the end of exit time will be
bypassed for that armed period. This feature, if selected, takes precedence over exit error.
Auto Unbypass
All burglary zones that are bypassed can be automatically unbypassed upon system disarm.
24-hour zones that have been bypassed are unbypassed only if they are normal.
This feature is ALWAYS enabled.
Manual Unbypass
This function removes an existing bypass from a currently bypassed zone. The procedure is
the same as Bypass.
User Code Programming
User codes can be entered or modified directly through the keypad. The system contains up
to six user codes (4 digits each) with the following applications:
USER
NUMBER
APPLICATION
DEFAULT
CODE
1
Master User (see note 1)
1234
2
Normal User
NULL
3
Normal User
NULL
4
Normal User
NULL
5
Arm Only (see note 2)
NULL
6
Ambush (see note 3)
NULL
NOTES:
1.
User Number 1 - programs all user codes (1-6); cannot be deleted.
2.
User Number 5 - can be programmed as an arm-only user in question 05, location 4. This
means that the user code can only arm but not disarm the system. Typically, this is used
for a maid service or any person with limited access.
3.
User Number 6 - can be programmed as an Ambush code if there is an Ambush CS
transmission code programmed into question 19, locations 1 and 2. In this mode, entry of
the user number 6 code will Arm or Disarm the system and transmit the Ambush code to
the central station. Furthermore, if opening/closing by user reporting is programmed,
user number 6 will be reported along with the Ambush code. If no CS code is defined in
question 19, then user number 6 will be a normal user code.
Summary of Contents for Omni-408A
Page 14: ...OMNI 408A Installation and Setup Guide 2 6 ...
Page 22: ...OMNI 408A Installation and Setup Guide 5 4 ...
Page 28: ...OMNI 408A Installation and Setup Guide 6 6 ...
Page 34: ...OMNI 408A Installation and Setup Guide 8 4 ...
Page 76: ...OMNI 408A Installation and Setup Guide 12 2 ...
Page 86: ...OMNI 408A Installation and Setup Guide B 4 ...
Page 88: ...OMNI 408A Installation and Setup Guide C 2 ...
Page 90: ...OMNI 408A Installation and Setup Guide D 2 ...
Page 92: ...OMNI 408A Installation and Setup Guide E 2 ...
Page 95: ......