OMNI-408A Installation and Setup Guide
9–26
QUESTION 26
RF ZONES
DEFAULT = 00A8
There are 4 locations (L1-L4) in this question:
Question 26, L1 - RF Zones 5-8
Default = 0
Question 26, L2 - RF Zones 1-4
Default = 0
L1 - RF Zones 5-8
L2 - RF Zones 1-4
RF ZONES
RF ZONES
Digit
8
7
6
5
Digit
4
3
2
1
0
None
0
None (Zones 1-4 are hardwired)
1
9
1
9
2
9
2
9
3
9
9
3
9
9
4
9
4
9
5
9
9
5
9
9
6
9
9
6
9
9
7
9
9
9
7
9
9
9
8
9
8
9
9
9
9
9
9
9
A
9
9
A
9
9
B
9
9
9
B
9
9
9
C
9
9
C
9
9
D
9
9
9
D
9
9
9
E
9
9
9
E
9
9
9
F
9
9
9
9
F
9
9
9
9
RF zone numbers must begin after assigned hardwired zone numbers. For example, if zones 1
through 4 were hardwired, the first RF zone number assigned is 5.
Any zone using an RF point must be enabled in this question so that the system knows
where to look for zone data.
To disable a RF point that has been previously programmed:
1.
Remove the RF enable for the appropriate zone in question 26; and
2.
Make the first 2 digits in the RF programming for that zone “00.”
Question 26, L3 - Disable Account
Default = A
This option is enabled when L3 is set to D. All other entries for L3 will not enable this
option. While this option is enabled, the system does not arm; and the Reporting code is
transmitted, with user number trying to arm (if the dialer format requires it), to the CS.
If the format is CID, the code for this event is 551 (Dialer Disabled Event code).
Summary of Contents for Omni-408A
Page 14: ...OMNI 408A Installation and Setup Guide 2 6 ...
Page 22: ...OMNI 408A Installation and Setup Guide 5 4 ...
Page 28: ...OMNI 408A Installation and Setup Guide 6 6 ...
Page 34: ...OMNI 408A Installation and Setup Guide 8 4 ...
Page 76: ...OMNI 408A Installation and Setup Guide 12 2 ...
Page 86: ...OMNI 408A Installation and Setup Guide B 4 ...
Page 88: ...OMNI 408A Installation and Setup Guide C 2 ...
Page 90: ...OMNI 408A Installation and Setup Guide D 2 ...
Page 92: ...OMNI 408A Installation and Setup Guide E 2 ...
Page 95: ......