![background image](http://html1.mh-extra.com/html/fbii/omni-408a/omni-408a_installation-and-setup-gude_547064056.webp)
OMNI-408A Installation and Setup Guide
9–22
Zone Alarm Codes
As specified previously, locations L3 and L4 of the zone questions represent the Alarm code
that is reported to the central station.
NOTE: Zones transmit to the central station unless these digits are defined as AA
for any individual zone; or unless the local dialer option is selected for all zones in
question 04, location 3.
Based on the dialer format selected, enter the Alarm code as follows:
STANDARD FORMAT (3X1 or 4X1): Enter the desired single-digit Alarm code in
location L3 for the specific zone. The value placed in L4 is not used.
EXTENDED (3X1 Ext. or 4X1 Ext.): Enter the desired first digit of the Alarm code for
the specific zone in location L3. Enter the second digit in L4.
PARTIAL EXTENDED (3X1 Part. Ext. or 4X1 Part. Ext.): Enter the desired digit in
both locations L3 and L4 for the specific zone. This generates a single-digit transmission
for alarms and troubles (the second digit is not used) and an extended transmission for
all system conditions such as restores, bypasses, openings/closings, etc. (the second digit
is used).
3X2 or 4x2: Enter the desired first digit of the Alarm code in location L3 and the second
digit in L4 for the specific zone. Both digits are used for all transmissions.
ADEMCO 4X2 EXPRESS: Enter the desired first digit of the Alarm code into the first
location and the second digit into the second location.
ADEMCO POINT ID (PID) Format: The digit entered in the first location selects the
PID Event code to be transmitted; refer to Appendix A for the PID Event Codes to be
selected.
The selections on the charts below are used to disable supervision for each zone.
For more information on CS Reporting Formats, refer to Appendix A at the back of this guide.
QUESTIONS 11 - 18 ZONES 1 - 8
There are 4 locations (L1-L4) within each of these questions that define the operation of the
zones. Enter a 2-digit number in locations L1 and L2 from the zone chart for the desired zone
type. Enter the desired Alarm code in locations L3 and L4 for this zone based on the dialer
format selected.
QUESTION 11
ZONE 1 TYPE & CS CODE
DEFAULT = 2061
Question 11, L1 & L2 - Zone 1 Type
Default = 20
Question 11, L3 & L4 - CS Code for Zone 1
Default = 61
Zone 1 = Delay (Entry/Exit) w/CS Reporting code = 61
QUESTION 12
ZONE 2 TYPE & CS CODE
DEFAULT = 4142
Question 12, L1 & L2 - Zone 2 Type
Default = 41
Question 12, L3 & L4 - CS Code for Zone 2
Default = 42
Zone 2 = Interior Follower w/CS Reporting code = 42
Summary of Contents for Omni-408A
Page 14: ...OMNI 408A Installation and Setup Guide 2 6 ...
Page 22: ...OMNI 408A Installation and Setup Guide 5 4 ...
Page 28: ...OMNI 408A Installation and Setup Guide 6 6 ...
Page 34: ...OMNI 408A Installation and Setup Guide 8 4 ...
Page 76: ...OMNI 408A Installation and Setup Guide 12 2 ...
Page 86: ...OMNI 408A Installation and Setup Guide B 4 ...
Page 88: ...OMNI 408A Installation and Setup Guide C 2 ...
Page 90: ...OMNI 408A Installation and Setup Guide D 2 ...
Page 92: ...OMNI 408A Installation and Setup Guide E 2 ...
Page 95: ......