OMNI-408A Installation and Setup Guide
5–2
INDEX
NO.
CONTROL/
INDICATOR
DESCRIPTION
2
ARM/DISARM
LED
This LED indicates whether the system is currently armed (on) or
disarmed (off). This LED will also blink fast to show that alarms have
occurred; or blink slowly upon failure to communicate with the central
station.
3
Stay LED
This LED displays whether the system has been armed in the Stay
mode or the Stay/Instant mode. If the Instant LED is on and the Stay
LED is on, then the system is in the Stay/Instant mode. If the Instant
LED is off and the Stay LED is on, then the system is in the Stay mode
only. Stay/Instant is enabled in programming question 08, location 3. In
either mode, the Stay LED indicates the following:
On — All zones enabled for Stay are bypassed.
Off — Zones are active-armed.
4
Instant LED
This LED displays whether the system has been armed in the
Stay/Instant mode, Instant mode, or indicates if the account is not being
monitored by the CS. Stay/Instant means that the system is currently
armed, all delay zones are Instant and all interior zones are bypassed.
Instant means that the system is currently armed, all delay zones are
Instant and no zones are bypassed.
NOTE: See programming question 08, location 3.
On — Delay zones are currently instant.
Off — Delay zones are normal.
Pulse — Central station is not monitoring the account.
5
AC/LB LED
This indicator light displays the current power status of the panel as
follows:
On — AC is present.
Off — No AC, running on battery backup.
Slow Blink — Low-battery condition detected.
6
READY LED
This LED displays whether the system is ready for arming. The READY
LED is common to all burglary zones with the following indications:
On — System ready to be armed.
Off — System not ready to be armed.
Slow Blink — Indicates Installer Programming mode.
Fast Blink — Alarm Memory mode.
7
[Stay] Key
The [Stay] key enables arming the system, excluding zones
programmed with the Stay option. This provides exterior protection of
the location while allowing full access throughout the interior. The [Stay]
key is also used to exit Installer Programming mode.
8
[Bypass] Key
The [Bypass] key is used to temporarily exclude protection of a specific
zone.
9
[Instant] Key
The [Instant] key enables arming the system, eliminating the entry
delays. If enabled with the [Stay] key, it enables arming the system in
the Stay/Instant mode.
NOTE: Instant modes are enabled in question 08, location 3.
10
[Code] Key
The [Code] key is used to enter the Installer Programming mode and for
entry of user codes.
Summary of Contents for Omni-408A
Page 14: ...OMNI 408A Installation and Setup Guide 2 6 ...
Page 22: ...OMNI 408A Installation and Setup Guide 5 4 ...
Page 28: ...OMNI 408A Installation and Setup Guide 6 6 ...
Page 34: ...OMNI 408A Installation and Setup Guide 8 4 ...
Page 76: ...OMNI 408A Installation and Setup Guide 12 2 ...
Page 86: ...OMNI 408A Installation and Setup Guide B 4 ...
Page 88: ...OMNI 408A Installation and Setup Guide C 2 ...
Page 90: ...OMNI 408A Installation and Setup Guide D 2 ...
Page 92: ...OMNI 408A Installation and Setup Guide E 2 ...
Page 95: ......