Section 8 - Installer Modes
8–3
5.
Press the [Stay] key to exit Programming mode. The control panel now dials the
downloading computer telephone number entered into the callback number. (If you have
not already selected the Unattended Communications option from the main menu of the
downloading computer, select it before continuing.) Upon connection with the computer,
the system obtains the customer account number programmed in step 3 and performs the
desired download operation.
NOTE: The CS downloading computer must be waiting in the Unattended Communications
option and preprogrammed with the account information in order for the Unattended
Download to be functional.
Installer Mode 4 (On-Line Download)
In this mode, the installer can initiate a remote communications session with the CS
Downloading computer at the control panel location. Typically, a remote communications
session is initiated by the CS. On-line downloading allows the installer to call the office (from
the same telephone line as the panel), discuss the action required, and allow the CS operator
to complete the request while on-line. No additional telephone call is needed. On-line
connection can be made as follows:
1.
After completing the installation, attach a handset to the telco terminals (tip and ring) or
use a standard home telephone to dial the CS downloading modem telephone line.
Connection is made with a person at the CS downloading computer and the account to be
downloaded is verbally identified. The downloading computer operator selects “On-line
Remote Operations” from the Device menu.
2.
Enter the on-line download sequence: [Code] [*] Installer Code, [4] or use the end-user
command of [#] [9], if enabled. This causes the control panel to react as if it has received
a request for a remote communications session, and to look for the standard panel to CS
protocol.
3.
Once the standard connection is made, the necessary remote communications sessions
can take place (Upload, Download, and Remote commands).
4.
Hang up the telephone or remove headset from the line to prevent interference that may
affect upload/download data. The downloader software automatically terminates the
connection after remote communications end.
Installer Mode 5 (Walk Test - Reduced Gain Mode)
This mode tests the RF receiver in a Reduced Gain mode. This mode is maintained until the
[Stay] key is pressed. The keypad displays this mode by pulsing the ARM, AC/LB, and
READY LEDs. An LED that is steadily on indicates the zone that is currently faulted. A
blinking LED indicates the zone has restored. The keypad sounder is activated on faulting
and restoring of zones. To exit, press the [Stay] key to cause a complete system reset.
All RF zones must be returned to normal before exiting Walk Test mode (i.e., doors and windows
should be closed). If these RF zones are not returned to normal, they will be displayed as normal
even though they are actually faulted.
Summary of Contents for Omni-408A
Page 14: ...OMNI 408A Installation and Setup Guide 2 6 ...
Page 22: ...OMNI 408A Installation and Setup Guide 5 4 ...
Page 28: ...OMNI 408A Installation and Setup Guide 6 6 ...
Page 34: ...OMNI 408A Installation and Setup Guide 8 4 ...
Page 76: ...OMNI 408A Installation and Setup Guide 12 2 ...
Page 86: ...OMNI 408A Installation and Setup Guide B 4 ...
Page 88: ...OMNI 408A Installation and Setup Guide C 2 ...
Page 90: ...OMNI 408A Installation and Setup Guide D 2 ...
Page 92: ...OMNI 408A Installation and Setup Guide E 2 ...
Page 95: ......