OMNI-408A Installation and Setup Guide
9–20
Burglary (Controlled) Zones
DELAY - This is the industry standard exit/entry zone. When the system is armed, exit time
begins. After the exit time expires, any violation of this zone begins entry time. If the system
is not disarmed within the programmed entry time, an alarm occurs. The keypad sounder
annunciates steadily during entry time, unless there has been an alarm condition, in which
case it pulses. Delay zones activate instantly when the system is armed using the
Stay/Instant mode, if enabled. Delay zones employ the Exit Error Warning feature described
below.
INTERIOR - All interior zones have exit delay time upon system arming. Furthermore, all
interior zones have entry delay time if a delay zone is violated first. If this zone is violated
first, however, it generates an immediate alarm. Interior zones are bypassed if the system is
armed in the Stay mode. Interior zones employ the Exit Error Warning feature described in
the note below.
PERIMETER - This zone type (sometimes known as Instant) generates an alarm when
violated while the system is armed.
EXIT ERROR WARNING - When a user code is entered to arm the system, the
burglary bell and keypad sounder are turned on during the entry and exit times.
Burglary Zone Options
RESTORE - This option is selected for all burglary zones by enabling the Restore report
code (question 19, location 2) and enabling zone Restores in question 04, location 4. The
programmed Restore code will be reported upon bell cutoff, assuming the loop is restored,
unless Restore Follows Loop is selected in question 05, location 4. The Restore code will also
be reported if the system is disarmed during an alarm.
NOTE: Restore is not selectable by zone.
BYPASS IN STAY - This option allows zones to be bypassed when the system is armed in
the Stay mode.
CHIME - If this option is selected, the keypad sounder will annunciate for 1 second when
this zone is violated in the disarmed mode.
DIALER DELAY - If this option is selected, the system will allow a 15-second delay (or 30
seconds, as per question 04, location 4) before dialing, allowing the end user to abort the
transmission. If this option is not selected, any alarm condition results in an immediate
transmission that cannot be aborted.
UL
For UL installations, Dialer Delay may not be used.
DAY FEATURE - If a zone with this option is violated while the system is disarmed, the
keypad sounder and zone LED pulse for as long as the violation remains. In addition, if the
violation remains for 15 seconds, the System Trouble Code is transmitted to the central
station. The sounder can be silenced through entry of any valid user code. While the system
is armed, a day zone acts as an alarm when violated.
Summary of Contents for Omni-408A
Page 14: ...OMNI 408A Installation and Setup Guide 2 6 ...
Page 22: ...OMNI 408A Installation and Setup Guide 5 4 ...
Page 28: ...OMNI 408A Installation and Setup Guide 6 6 ...
Page 34: ...OMNI 408A Installation and Setup Guide 8 4 ...
Page 76: ...OMNI 408A Installation and Setup Guide 12 2 ...
Page 86: ...OMNI 408A Installation and Setup Guide B 4 ...
Page 88: ...OMNI 408A Installation and Setup Guide C 2 ...
Page 90: ...OMNI 408A Installation and Setup Guide D 2 ...
Page 92: ...OMNI 408A Installation and Setup Guide E 2 ...
Page 95: ......