OMNI-408A Installation and Setup Guide
9–10
QUESTION 06
SYSTEM TIMEOUTS
DEFAULT = 6622
There are 4 locations (L1-L4) within this question, which defines various system timing
options, as follows:
Question 06, L1
Entry Delay 1
Default = 6
Enter the desired entry delay time for zones 1-3. Refer to Exit/Entry Times below for valid
choices. If zones 1-3 are delay zones, they follow Entry Delay 1. For UL applications,
the maximum Entry Delay shall not exceed 45 seconds for household applications or 15
seconds for commercial burglary applications.
NOTE: See programming question 07, location 1 for Entry Delay 2.
Digit
ENTRY TIMEOUTS
0
1 second
1
5 seconds
2
10 seconds
3
15 seconds
4
20 seconds
5
25 seconds
6
30 seconds
7
35 seconds
8
40 seconds
9
45 seconds
A
50 seconds
B
55 seconds
C
1 minute
D
1 minute 5 seconds
E
1 minute 10 seconds
F
3 minutes