5–1
S E C T I O N 5
The XK-108 Keypad
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
In This Section
♦
XK-108 Keypad
♦
Keypad Sounder
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
XK-108 Keypad
ARM
AC/LB
READY
1
2
3
4
5
6
7
8
Stay
Instant
COVER
OPEN
Stay
Instant
Bypass
Code
*
0
#
7
8
9
4
5
6
1
2
3
P
A
F
2
3
6
1
3
4
7
9
10
8
11
RF LB
Superv
12
13
Figure 6. XK-108 Keypad
Table 1. XK-108 Keypad Controls and Indicators
INDEX
NO.
CONTROL/
INDICATOR
DESCRIPTION
1
Zone Status
LEDS
These LEDs display the current zone status, including alarms,
bypasses, troubles, and faults. Each condition will cause these LEDs to
operate differently, as follows:
Alarms — Fast Blink (approx. 150mS on - 150mS off).
Troubles — Slow Pulse (approx. 600mS on - 600mS off).
Bypasses — Wink (100mS on - 900mS off). Zone bypasses are
displayed as a very slow wink of the zone LED light.
Faulted Zones — Solid on. Faulted zones are the lowest-priority
indication. Faulted burglary zones are displayed with the LED solidly on
while the system is disarmed.
Normal — Off.
Summary of Contents for Omni-408A
Page 14: ...OMNI 408A Installation and Setup Guide 2 6 ...
Page 22: ...OMNI 408A Installation and Setup Guide 5 4 ...
Page 28: ...OMNI 408A Installation and Setup Guide 6 6 ...
Page 34: ...OMNI 408A Installation and Setup Guide 8 4 ...
Page 76: ...OMNI 408A Installation and Setup Guide 12 2 ...
Page 86: ...OMNI 408A Installation and Setup Guide B 4 ...
Page 88: ...OMNI 408A Installation and Setup Guide C 2 ...
Page 90: ...OMNI 408A Installation and Setup Guide D 2 ...
Page 92: ...OMNI 408A Installation and Setup Guide E 2 ...
Page 95: ......