• The switch looks for the first set of these attributes that have the same Tag value and
fulfil the following requirements (if Tag == 0 is used, the Tunnel-Private-Group-ID does
not
need
to
include
a Tag):
- Value of Tunnel-Medium-Type must be set to "IEEE-802" (ordinal 6).
- Value of Tunnel-Type must be set to "VLAN" (ordinal 13).
- Value of Tunnel-Private-Group-ID must be a string of ASCII chars in the range '0' -
'9', which is interpreted as a decimal string representing the VLAN ID. Leading '0's are
discarded. The final value must be in the range [1; 4095].
Guest VLAN Enabled
enabled and enabled (checked) for a given port, the
switch considers moving the port into the Guest VLAN according to the rules outlined
below.
This option is only available for EAPOL-based modes, i.e.:
• Port-based 802.1X
•
Single
802.1X
•
Multi
802.1X
For trouble-shooting VLAN assignments, use the "Monitor→VLANs→VLAN Membership
and VLAN Port" pages. These pages show which modules have (temporarily) overridden the
current
Port
VLAN
configuration.
Guest
VLAN
Operation:
When a Guest VLAN enabled port's link comes up, the switch starts transmitting EAPOL
Request Identity frames. If the number of transmissions of such frames exceeds
and no EAPOL frames have been received in the meanwhile, the switch
considers entering the Guest VLAN. The interval between transmission of EAPOL Request
Identity frames is configured with
. If
Allow Guest VLAN if EAPOL Seen
enabled, the port will now be placed in the Guest VLAN. If disabled, the switch will first
check its history to see if an EAPOL frame has previously been received on the port (this
history is cleared if the port link goes down or the port's
not, the port will be placed in the Guest VLAN. Otherwise it will not move to the Guest
VLAN, but continue transmitting EAPOL Request Identity frames at the rate given by EAPOL
Timeout.
Once in the Guest VLAN, the port is considered authenticated, and all attached clients on
the port are allowed access on this VLAN. The switch will not transmit an EAPOL Success
frame
when
entering
the
Guest
VLAN.
While in the Guest VLAN, the switch monitors the link for EAPOL frames, and if one such
frame is received, the switch immediately takes the port out of the Guest VLAN and starts
authenticating the supplicant according to the port mode. If an EAPOL frame is received,
the port will never be able to go back into the Guest VLAN if the "Allow Guest VLAN if
EAPOL Seen" is disabled.
Port State :
The current state of the port. It can undertake one of the following values:
Globally Disabled: IEEE 802.1X is
Link Down: IEEE 802.1X is globally enabled, but there is no link on the port.
Authorized: The port is in
or a single-supplicant mode and the supplicant
is authorized.
Unauthorized: The port is in
or a single-supplicant mode and the
supplicant is not successfully authorized by the RADIUS server.
X Auth/Y Unauth: The port is in a multi-supplicant mode. Currently X clients are authorized
and Y are unauthorized.
Restart :
Two buttons are available for each row. The buttons are only enabled when authentication
Summary of Contents for Cross-8/HPoE-10G
Page 1: ......
Page 4: ......
Page 9: ...19 4 2 Firmware Selection 350 ...
Page 10: ...Revision History ...
Page 85: ... Reset Click to undo any changes made locally and revert to previously saved values ...
Page 111: ...Click to undo any changes made locally and revert to previously saved values ...
Page 116: ...Click to undo any changes made locally and revert to previously saved values ...