29. InDICatIon of SYStEM faUltS
the system comes equipped with self-diagnostic feature allowing to indicate the presence of any system fault by the keypad as well as by
SMS text message notification to the listed user phone number. By default the indication for all system faults is indicated on the keypad.
to disable/enable the indication of a certain system fault, please refer to the following configuration method.
Disable/enable
individual system fault
indication on keypad
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.
attEntIon:
After enabling/disabling a certain system fault indication, it is necessary to restart the system locally by powering down and
powering up the system the system or remotely (see
34. rEMotE SYStEM rEStart
).
EKB2
icon displayed in home screen view indicates presence of system and/or eWM1 device faults. In order to view the currently
present system faults, please enter a valid user/master code to access menu section
faUltS
. the description on each system
fault is provided in the table below.
View system faults
Menu path:
OK
→
uumm
→
OK
→
FAULtS
→
OK
Value:
uumm
– 4-digit user/master code.
name
Description
MAIN POWeR LOSS
Mains power is lost
LOW BAtteRY
Low backup battery power - backup battery voltage is 10.5V or lower
BAtteRY DeAD/MISS
Backup battery is not present or the battery voltage runs below 5V
BAtteRY FAILeD
Backup battery requires replacement - backup battery resistance is 2Ω or higher
SIReN FAILeD
Wired siren is disconnected/broken
VIOLAteD tAMPeR
One or more tampers are violated
DAte/tIMe NOt Set
Date/time not set
GSM CONNeCt FAILeD
GSM connection is lost
GSM ANteNNA FAILeD
GSM/GPRS antenna is disconnected/broken
WLeSS ANteNNA FAIL
Wireless antenna is disconnected/broken
COMM BUS FAILeD
RS485 device, such as keypad, eLAN3-ALARM or ePGM1 is disconnected/broken
CO LeVeL CRItICAL
Critical level 4 of carbon monoxide (CO) concentration detected by eWF1CO is reached
eWM1 FAULt
One or more eWM1 device faults exist - enter this menu item to view the existing eWM1
device faults.
WLeSS BAtt LOW
Low wireless device battery power - battery level is running below 5%
RF JAMMeR DeteCteD
Wireless signal is blocked by jammer
MS COMM. FAILeD
Communication with monitoring station failed
Alternatively, existing eWM1 device faults can be viewed by accessing menu section
faUltS
of the PGM output associated
with a certain eWM1 device.
View EWM1 faults
Menu path:
OK
→
mmmm
→
OK
→
PGM OUtPUtS
→
OK
→
out-name
→
OK
→
FAULtS
→
OK
Value:
mmmm
– 4-digit master code;
out-name
- PGM output name associated with a
certain eWM1 device.
name
Description
OVeRVOLtAGe
Voltage has increased above 260VAC
UNDeRVOLtAGe
Voltage has dropped below 190VAC
OVeRCURReNt
Current has increased above 12,5A
ReLAY FAULt
Unable to power up the appliance due to faulty relay
teMP. FAULt
environmental temperature has dropped below -35°C (-31°F) or increased above
+90°C (+194°F)
In order to clear the existing faults, please press the
button on eWM1, turn OFF the electrical appliance or turn OFF the
wireless PGM output associated with eWM1. For more details on eWM1 device, please refer to
19.9. EWM1 - Wireless Power