background image

X00383                                                                  November 2012                        Portable_HomeGuard_32_instr_v01.cdr

Portable   Monitor 

for

 wireless outdoor  and indoor  sensors

M A M I

Preliminary issue

M A M I

MANUFACTURING AND MINOR INVENTIONS

HomeGuard 32

Summary of Contents for HomeGuard 32

Page 1: ...X00383 November 2012 Portable_HomeGuard_32_instr_v01 cdr Portable Monitor for wireless outdoor and indoor sensors MAMI Prelim inary issue MAMI MANUFACTURING AND MINOR INVENTIONS HomeGuard 32...

Page 2: ...OPTIONS INTERNAL BUZZER SCHEDULE BYPASS SETTING THE SYSTEM TIME DATE SETTING THE TRANSMITTER CODE NAMING OF ZONES SETTING LEVELS CHANGING USER CODE SELF LEARNING DETECTORS SELF LEARNING REMOTE S NAMIN...

Page 3: ...3 entries Optional External Antenna On Board wireless receiver and Transmitter Receiver frequency at 433MHz Transmitter at 403MHz 6 External triggers through transmitter Supports MAMI Silentron and O...

Page 4: ...ARMED DISARMED Suppose the unit is armed and power is switched off and on the unit will remain armed after it switches back ON Warn Chime mode The HomeGuard32 is capable of going into a Warn Chime mo...

Page 5: ...isarm Arms to Level A only Pg 5 Setting Transmitter code Pg 6 0 0 5 0 1 0 0 1 1 0 1 0 Change User Code Pg 7 0 2 2 0 1 0 Clear All Remote Controls Pg 10 0 2 1 0 1 0 Deleting Devices Pg 9 Warning Mode L...

Page 6: ...d a tamper signal the user must turn bit 8 of the dip switch off a tamper signal will then be sent to resend press the tamper button If the user wishes to leave the tamper active the user must leave b...

Page 7: ...nters the time the user then enters the hash key saving the time corresponding to the time the unit will automatically arm SCHEDULE 1 DISARM time will be displayed Indicating that the time for schedul...

Page 8: ...nd no changes will be made Buzzer option 0 0 2 0 1 0 1 Buzzer will be displayed The user may then enter 1 or 0 to toggle the buzzer on or off respectively 1 0 BUZZER ON BUZZER OFF Save Changes Once th...

Page 9: ...o exit Continue with zone Z keyed in Naming Renaming of Zones Z 2 ABC Exit Z 0 0 A 0 1 0 Setting Level The user must key in the user code followed by 0 then the level A B C or D the user must select a...

Page 10: ...star to continue and hash to save and Exit Remote Added Trigger Remote Trigger Device EXIT Continue EXIT Continue The user is then prompted to either replace an existing device or add as new Replace E...

Page 11: ...roll Next A Scroll Previous D Save Changes B Back space 2 ABC 0 Space or 0 If the user entered the C key the user has to trigger the device to rename if the code is not in the system error will be dis...

Page 12: ...RN or Chime mode In this mode the unit will not trigger an alarm but sound a chime when any detector in the level has been triggered To set warn Level A D The User simply Holds down desired Key A D an...

Page 13: ...ll alarm and arming or disarming the unit are logged on to the units EEPROM a maximum of 80 different alarms can be logged Each log displays the time date type of alarm and Zone information in the cas...

Page 14: ...e name or the zone number together with the device either the device name or the device number BattLow LOUNGE WINDOW BATTERY LOW ON SENSORS ALERT BattLow Zone 5 Device 1 In the case that any of the se...

Page 15: ...e the battery EXTERNAL BUZZER When the unit is wall mounted with a power source plugged in 12V dc is available at the buzzer Output EXTERNAL LED The external Led Output will supply 12volts DC to the L...

Page 16: ...YSTEM 1000 2 9 RESET ENTIRE UNIT TO DEFAULT 1000 3 3 VIEW DEVICE LOG PANIC PANIC ACTIVATION NOTES A A Means Press and hold the A key until it beeps A A Means Press and hold the and the A keys until it...